Notifications
You must be signed in to change notification settings - Fork 2
Parameters_SM_42BYG011_25
Kanta HORIO edited this page Oct 21, 2020
·
2 revisions
Datasheet | Measured | |
---|---|---|
Voltage | 12V | |
Phase Current | 0.33A | |
Resistance | 34ohm | 34.2ohm |
Inductance | 46mH | 45.0mH |
Holding Torque | 0.23Nm | |
Ke [V/Hz] | 0.0763 |
Parameter | 24V | 48V |
---|---|---|
KVAL_HOLD | 20 | 10 |
KVAL_RUN | 169 | |
KVAL_ACC | 169 | |
KVAL_DEC | 169 | |
INT_SPEED | 8070 | |
ST_SLP | 52 | |
FN_SLP_ACC | 142 | |
FN_SLP_DEC | 142 |
Config file(24V) : config.txt
- home
- Tutorial
-
Connections and settings
- Power supply and Motor
- Sensor and Switch
- Network and DIP switch
- Setup with a microSD card
- Example parameter values for example steppers
- Function description
- OSC command reference
- Technical information