- RFMXSPECAN_ATTR_TXP_MEASUREMENT_ENABLED
- RFMXSPECAN_ATTR_TXP_MEASUREMENT_INTERVAL
- RBW Filter
- VBW Filter
- RFMXSPECAN_ATTR_TXP_VBW_FILTER_VBW_TO_RBW_RATIO
- Threshold
- Averaging
- RFMXSPECAN_ATTR_TXP_ALL_TRACES_ENABLED
- RFMXSPECAN_ATTR_TXP_NUMBER_OF_ANALYSIS_THREADS
- Results
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the TXP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_TXPGetMeasurementEnabled Set Function: RFmxSpecAn_TXPSetMeasurementEnabled |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the acquisition time for the TXP measurement. This value is expressed in seconds. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0.001. Get Function: RFmxSpecAn_TXPGetMeasurementInterval Set Function: RFmxSpecAn_TXPSetMeasurementInterval |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the bandwidth of the resolution bandwidth (RBW) filter used to measure the signal. This value is expressed in Hz. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 100 kHz. Get Function: RFmxSpecAn_TXPGetRBWFilterBandwidth Set Function: RFmxSpecAn_TXPSetRBWFilterBandwidth |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the shape of the digital resolution bandwidth (RBW) filter. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_TXP_RBW_FILTER_TYPE_GAUSSIAN. Get Function: RFmxSpecAn_TXPGetRBWFilterType Set Function: RFmxSpecAn_TXPSetRBWFilterType |
Values: |
RFMXSPECAN_VAL_TXP_RBW_FILTER_TYPE_NONE (1) | The RBW filter has a Gaussian response. |
---|---|
RFMXSPECAN_VAL_TXP_RBW_FILTER_TYPE_GAUSSIAN (2) | The RBW filter has a flat response. |
RFMXSPECAN_VAL_TXP_RBW_FILTER_TYPE_FLAT (5) | The measurement does not use any RBW filtering. |
RFMXSPECAN_VAL_TXP_RBW_FILTER_TYPE_RRC (6) | The RRC filter with the roll-off specified by the RFMXSPECAN_ATTR_TXP_RBW_FILTER_ALPHA attribute is used as the RBW filter. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the roll-off factor for the root-raised-cosine (RRC) filter. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0.1. Get Function: RFmxSpecAn_TXPGetRBWFilterAlpha Set Function: RFmxSpecAn_TXPSetRBWFilterAlpha |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether the video bandwidth (VBW) is expressed directly or computed based on the VBW to RBW ratio. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_TXP_VBW_FILTER_AUTO_BANDWIDTH_TRUE. Get Function: RFmxSpecAn_TXPGetVBWFilterAutoBandwidth Set Function: RFmxSpecAn_TXPSetVBWFilterAutoBandwidth |
Values: |
RFMXSPECAN_VAL_TXP_VBW_FILTER_AUTO_BANDWIDTH_FALSE (0) | Specify the video bandwidth in the RFMXSPECAN_ATTR_TXP_VBW_FILTER_BANDWIDTH attribute. The RFMXSPECAN_ATTR_TXP_VBW_FILTER_VBW_TO_RBW_RATIO attribute is disregarded in this mode. |
---|---|
RFMXSPECAN_VAL_TXP_VBW_FILTER_AUTO_BANDWIDTH_TRUE (1) | Specify video bandwidth in terms of the VBW to RBW ratio. The value of the video bandwidth is then computed by using the RFMXSPECAN_ATTR_TXP_VBW_FILTER_VBW_TO_RBW_RATIO attribute and the RFMXSPECAN_ATTR_TXP_RBW_FILTER_BANDWIDTH attribute. The value of the RFMXSPECAN_ATTR_TXP_VBW_FILTER_BANDWIDTH attribute is disregarded in this mode. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the video bandwidth when you set the RFMXSPECAN_ATTR_TXP_VBW_FILTER_AUTO_BANDWIDTH attribute to RFMXSPECAN_VAL_TXP_VBW_FILTER_AUTO_BANDWIDTH_FALSE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 30000. Get Function: RFmxSpecAn_TXPGetVBWFilterBandwidth Set Function: RFmxSpecAn_TXPSetVBWFilterBandwidth |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies the VBW to RBW Ratio when you set the RFMXSPECAN_ATTR_TXP_VBW_FILTER_AUTO_BANDWIDTH attribute to RFMXSPECAN_VAL_TXP_VBW_FILTER_AUTO_BANDWIDTH_TRUE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 3. Get Function: RFmxSpecAn_TXPGetVBWFilterVBWToRBWRatio Set Function: RFmxSpecAn_TXPSetVBWFilterVBWToRBWRatio |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable thresholding of the acquired samples to be used for the TXP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_FALSE. Get Function: RFmxSpecAn_TXPGetThresholdEnabled Set Function: RFmxSpecAn_TXPSetThresholdEnabled |
Values: |
RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_FALSE (0) | All the acquired samples are considered for the TXP measurement. |
---|---|
RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_TRUE (1) | The samples above the threshold level specified in the RFMXSPECAN_ATTR_TXP_THRESHOLD_LEVEL attribute are considered for the TXP measurement. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the reference for the power level used for thresholding. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_TXP_THRESHOLD_TYPE_RELATIVE. Get Function: RFmxSpecAn_TXPGetThresholdType Set Function: RFmxSpecAn_TXPSetThresholdType |
Values: |
RFMXSPECAN_VAL_TXP_THRESHOLD_TYPE_RELATIVE (0) | The threshold is relative to the peak power of the acquired samples. |
---|---|
RFMXSPECAN_VAL_TXP_THRESHOLD_TYPE_ABSOLUTE (1) | The threshold is the absolute power, in dBm. |
Data Type: | float64 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeF64 RFmxSpecAn_GetAttributeF64 |
Description: | Specifies either the relative or absolute threshold power level based on the value of the RFMXSPECAN_ATTR_TXP_THRESHOLD_TYPE attribute. The default value is -20. Get Function: RFmxSpecAn_TXPGetThresholdLevel Set Function: RFmxSpecAn_TXPSetThresholdLevel |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable averaging for the TXP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_TXP_AVERAGING_ENABLED_FALSE. Get Function: RFmxSpecAn_TXPGetAveragingEnabled Set Function: RFmxSpecAn_TXPSetAveragingEnabled |
Values: |
RFMXSPECAN_VAL_TXP_AVERAGING_ENABLED_FALSE (0) | The measurement is performed on a single acquisition. |
---|---|
RFMXSPECAN_VAL_TXP_AVERAGING_ENABLED_TRUE (1) | The TXP measurement uses the RFMXSPECAN_ATTR_TXP_AVERAGING_COUNT attribute as the number of acquisitions over which the TXP measurement is averaged. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the number of acquisitions used for averaging when you set the RFMXSPECAN_ATTR_TXP_AVERAGING_ENABLED attribute to RFMXSPECAN_VAL_TXP_AVERAGING_ENABLED_TRUE. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10. Get Function: RFmxSpecAn_TXPGetAveragingCount Set Function: RFmxSpecAn_TXPSetAveragingCount |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the averaging type for the TXP measurement. The averaged power trace is used for the measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_TXP_AVERAGING_TYPE_RMS. Get Function: RFmxSpecAn_TXPGetAveragingType Set Function: RFmxSpecAn_TXPSetAveragingType |
Values: |
RFMXSPECAN_VAL_TXP_AVERAGING_TYPE_RMS (0) | The power trace is linearly averaged. |
---|---|
RFMXSPECAN_VAL_TXP_AVERAGING_TYPE_LOG (1) | The power trace is averaged in a logarithmic scale. |
RFMXSPECAN_VAL_TXP_AVERAGING_TYPE_SCALAR (2) | The square root of the power trace is averaged. |
RFMXSPECAN_VAL_TXP_AVERAGING_TYPE_MAXIMUM (3) | The maximum instantaneous power in the power trace is retained from one acquisition to the next. |
RFMXSPECAN_VAL_TXP_AVERAGING_TYPE_MINIMUM (4) | The minimum instantaneous power in the power trace is retained from one acquisition to the next. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the TXP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXSPECAN_VAL_FALSE. Get Function: RFmxSpecAn_TXPGetAllTracesEnabled Set Function: RFmxSpecAn_TXPSetAllTracesEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxSpecAn_SetAttributeI32 RFmxSpecAn_GetAttributeI32 |
Description: | Specifies the maximum number of threads used for parallelism for TXP measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 1. Get Function: RFmxSpecAn_TXPGetNumberOfAnalysisThreads Set Function: RFmxSpecAn_TXPSetNumberOfAnalysisThreads |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the mean power of the signal. This value is expressed in dBm. Only the samples above the threshold are used by the measurement when you set the RFMXSPECAN_ATTR_TXP_THRESHOLD_ENABLED attribute to RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_TRUE. When you set the RFMXSPECAN_ATTR_TXP_AVERAGING_ENABLED attribute to RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_TRUE, the mean power is measured using the power trace averaged over multiple acquisitions. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_TXPGetResultsAverageMeanPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the ratio of the peak power of the signal to the mean power. Only the samples above the threshold are used by the measurement when you set the RFMXSPECAN_ATTR_TXP_THRESHOLD_ENABLED attribute to RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_TRUE. When you set the RFMXSPECAN_ATTR_TXP_AVERAGING_ENABLED attribute to RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_TRUE, the peak and mean powers are measured using the power trace averaged over multiple acquisitions. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_TXPGetResultsPeaktoAverageRatio |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the maximum power of the averaged power trace. This value is expressed in dBm. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_TXPGetResultsMaximumPower |
Data Type: | float64 |
---|---|
Access: | read only |
Functions: | RFmxSpecAn_GetAttributeF64 |
Description: | Returns the minimum power of the averaged power trace. This value is expressed in dBm. You do not need to use a selector string to read this result for default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals and results. Get Function: RFmxSpecAn_TXPGetResultsMinimumPower |
Creating and Setting Up a gRPC Server
Session Utilities API Reference
gRPC API Differences From C API
Sharing Driver Sessions Between Clients
C API Docs
NI-DAQmx
- gRPC API Differences From C API
- Task Configuration And Control
- Channel Configuration And Creation
- Timing
- Triggering
- Read Functions
- Write Functions
- Export Hardware Signals
- Scale Configuration
- Internal Buffer Configuration
- Advanced Functions
- System Configuration
- Error Handling
- Buffer Attributes
- Calibration Info Attributes
- Channel Attributes
- Device Attributes
- Export Signal Attributes
- Persisted Channel Attributes
- Persisted Scale Attributes
- Persisted Task Attributes
- Physical Channel Attributes
- Read Attributes
- Scale Attributes
- System Attributes
- Task Attributes
- Timing Attributes
- Trigger Attributes
- Watchdog Attributes
- Write Attributes
NI-DCPOWER
- Setup Functions
- Configure Functions
- Measurement Functions
- Control Functions
- Trigger And Event
- Attribute Functions
- Query Functions
- Calibration Functions
- Utility Functions
- Supported Device
- Source Attributes
- Transient Attributes
- Voltage Attributes
- Current Attributes
- Pulse Voltage Attributes
- Pulse Current Attributes
- Cutoff Attributes
- Measurement Attributes
- Trigger Attributes Functions
- Event Attributes
- Advanced Attributes
- Inherent Ivi Attributes
- Supported Device Attributes
NI-DIGITAL PATTERN DRIVER
- Init And Close Functions
- Session Locking Functions
- Utility Functions
- Error Handling Functions
- Calibration Functions
- Attributes Functions
- Pin Map Functions
- Low Level Functions
- Low Level Action Functions
- Pin Control Functions
- Static IO Functions
- Clock Generator Functions
- Levels And Timing Functions
- TDR Functions
- PPMU Configuration Functions
- DC Voltage Functions
- DC Current Functions
- PPMU Action Functions
- Pattern Configuration Functions
- Pattern Action Functions
- History Ram Functions
- Source Memory Functions
- Capture Memory Functions
- Triggers And Events Functions
- Conditional Jump Trigger Functions
- Sequencer Flag Functions
- Sequencer Register Functions
- Match Fail Combination Functions
- Pattern Results Functions
- Sort Results Functions
- Frequency Measurement Functions
- IVI Inherent Attributes
- Specific Driver Information Attributes, Read Only
- Driver Setup Information Attributes
- Device Attributes
- Pin Control Attributes
- Level Configuration Attributes
- Trigger Configuration Attributes
- PPMU Attributes
- Patterns Attributes
- Pattern Opcode Event Attributes
- Timing Offset Attributes
- Keep Alive Attributes
- Frequency Measurement Attributes
- Clock Generator Attributes
- History RAM
- Synchronization Attributes
- TDR Endpoint Termination Attributes
NI-FGEN
- Setup Functions
- Configuration Functions
- Standard Output Functions
- Arbitrary Waveform Output Functions
- Arbitrary Sequence Output Functions
- Incremental Waveform Write Functions
- Configure Clock Functions
- Trigger And Syncronizations Functions
- 5404 Routing Functions
- Script Output Functions
- Configure Onboard Signal Processing Functions
- Configure Peer To Peer Functions
- Attribute Functions
- Waveform Control Functions
- Error Functions
- Output Attributes
- Arbitrary Waveform Attributes
- Data Transfer Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Attributes
- Standard Function Attributes
- Clock Attributes
- Event Attributes
- Triggering Attributes
- Instrument Specific Attributes
- Inherent IVI Attributes
- 5401 5411 5431
NI-RFmx Bluetooth
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Packet Attributes
- Auto Detect Signal Attributes
- Modacc Attributes
- ACP Attributes
- Twenty dB Attributes
- Frequency Range Attributes
- TXP Attributes
- Advanced Attributes
NI-RFmx NR
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attributes Functions
- Fetch Results Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Signal Detection Attributes
- Component Carrier Attributes
- List Attributes
- Modacc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- TXP Attributes
- Pvt Attributes
- Advanced Attributes
NI-RFmx LTE
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Ch Configuration Functions
- NB IoT Configuration Functions
- ModAcc Configuration Functions
- ACP Configuration Functions
- CHP Configuration Functions
- OBW Configuration Functions
- SEM Configuration Functions
- PVT Configuration Functions
- SlotPhase Configuration Functions
- SlotPower Configuration Functions
- Set And Get Attribute Functions
- ModAcc Fetch Functions
- ACP Fetch Functions
- CHP Fetch Functions
- OBW Fetch Functions
- SEM Fetch Functions
- PVT Fetch Functions
- SlotPhase Fetch Functions
- SlotPower Fetch Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- Component Carrier Attributes
- ModAcc Attributes
- ACP Attributes
- CHP Attributes
- OBW Attributes
- SEM Attributes
- PVT Attributes
- SlotPhase Attributes
- SlotPower Attributes
- Advanced Attributes
NI-RFmx SpecAn
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Read Functions
- Fetch Functions
- Utility Functions
- Marker Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- ACP Attributes
- Cdf Attributes
- CHP Attributes
- Fcnt Attributes
- Harm Attributes
- OBW Attributes
- SEM Attributes
- Spectrum Attributes
- Spur Attributes
- TXP Attributes
- AMPM Attributes
- Dpd Attributes
- IQ Attributes
- IM Attributes
- NF Attributes
- Phasenoise Attributes
- PAVT Attributes
- Advanced Attributes
NI-RFmx WLAN
- gRPC API Differences From C API
- General Functions
- Configuration Functions
- Set And Get Attribute Functions
- Fetch DSSS ModAcc Functions
- Fetch OFDM ModAcc Functions
- Fetch SEM Functions
- Fetch TXP Functions
- Fetch PowerRamp Functions
- Utility Functions
- Build String Functions
- Advanced Functions
- General Attributes
- Trigger Attributes
- OFDM Attributes
- Auto Detect Signal Attributes
- DSSS ModAcc Attributes
- OFDM ModAcc Attributes
- SEM Attributes
- TXP Attributes
- PowerRamp Attributes
- Advanced Attributes
NI-RFSA
- General Functions
- Configuration Functions
- Acquisition Functions
- Utility Functions
- Calibration Functions
- General Attributes
- Vertical Attributes
- Signal Path Attributes
- Acquisition Attributes
- Acquisition Attributes
- Triggers Attributes
- Events Attributes
- Device Characteristics Attributes
- Peer To Peer Streaming Attributes
- Configuration List Attributes
- Inherent IVI Properties Attributes
- De-embedding Attributes
- Self Calibration Attributes
- Factory Calibration Attributes
- External Alignment Attributes
- Device Specific Attributes
NI-RFSG
- General Functions
- Generation Configuration
- Utility Functions
- Calibration Functions
- Arb Attributes
- Clock Attributes
- Configuration List Attributes
- De-embedding Attributes
- Device Characteristics Attributes
- Device Specific Attributes
- Events Attributes
- External Calibration Attributes
- Inherent IVI Attributes Attributes
- IQ Impairment Attributes
- Load Configurations Attributes
- Modulation Attributes
- Obsolete Attributes
- Peer To Peer Attributes
- RF Attributes
- Self Calibration Attributes
- Triggers Attributes
NI-SCOPE
- Setup Functions
- Configure Functions
- Attribute Functions
- Acquisition Functions
- Measurement Functions
- Calibrate Functions
- Utility Funcitons
- Error Handling Functions
- IVI Compliance Or Obsolete Functions
- Vertical Attributes
- Horizontal Attributes
- Trigger Attributes
- Clocking Attributes
- Synchronization Attributes
- Acquisition Attributes
- Waveform Measurements Attributes
- Onboard Signal Processing Attributes
- Peer To Peer Streaming Attributes
- Device Attributes
- IVI Or Obsolete Attributes
- Instrument Capabilities Attributes
- If Digitizer Attributes
NI-XNET
- gRPC API differences from C APIs
- General Functions
- Cluster Properties
- Database Properties
- Device Properties
- ECU Properties
- Frame Properties
- Interface Properties
- LIN Schedule Entry Properties
- LIN Schedule Properties
- PDU Properties
- Session Ethernet Properties
- Session Frame Properties
- Session Interface Properties
- Session Properties
- Session SAE J1939 Properties
- Signal Properties
- Subframe Properties
- System Properties
- IP-Stack Functions
- Socket Options
- Socket Functions