RFMXSPECAN_ATTR_PAVT_MEASUREMENT_ENABLED

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies whether to enable the Phase Amplitude Versus Time (PAVT) measurement.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is RFMXSPECAN_VAL_FALSE.

Get Function: RFmxSpecAn_PAVTGetMeasurementEnabled
Set Function: RFmxSpecAn_PAVTSetMeasurementEnabled

RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LOCATION_TYPE

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies whether the location at which the segment is measured is indicated by time or trigger.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TIME.

Get Function: RFmxSpecAn_PAVTGetMeasurementLocationType
Set Function: RFmxSpecAn_PAVTSetMeasurementLocationType
Values:
RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TIME (0) The measurement is performed over a single record across multiple segments separated in time. The measurement locations of the segments are specified by the RFMXSPECAN_ATTR_PAVT_SEGMENT_START_TIME attribute. The number of segments is equal to the number of segment start times.
RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TRIGGER (1) The measurement is performed across segments obtained in multiple records, where each record is obtained when a trigger is received. The number of segments is equal to the number of triggers (records).

RFMXSPECAN_ATTR_PAVT_MEASUREMENT_BANDWIDTH

Data Type: float64
Access: read/write
Functions: RFmxSpecAn_SetAttributeF64
RFmxSpecAn_GetAttributeF64
Description: Specifies the bandwidth over which the signal is measured. This value is expressed in Hz.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is 10 MHz.

Get Function: RFmxSpecAn_PAVTGetMeasurementBandwidth
Set Function: RFmxSpecAn_PAVTSetMeasurementBandwidth

RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies the mode of configuring the measurement interval.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM.

Get Function: RFmxSpecAn_PAVTGetMeasurementIntervalMode
Set Function: RFmxSpecAn_PAVTSetMeasurementIntervalMode
Values:
RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM (0) The time offset from the start of segment and the duration over which the measurement is performed is uniform for all segments and is given by the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_OFFSET attribute and the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LENGTH attribute respectively.
RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_VARIABLE (1) The time offset from the start of segment and the duration over which the measurement is performed is configured separately for each segment and is given by the RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_OFFSET attribute and the RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_LENGTH attribute respectively.

RFMXSPECAN_ATTR_PAVT_NUMBER_OF_SEGMENTS

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies the number of segments to be measured.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is 1.

Get Function: RFmxSpecAn_PAVTGetNumberOfSegments
Set Function: RFmxSpecAn_PAVTSetNumberOfSegments

RFMXSPECAN_ATTR_PAVT_SEGMENT_TYPE

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies the type of segment.

Use 'segment(n)' as the selector string to configure or read this attribute.

The default value is RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_PHASE_AND_AMPLITUDE.

Get Function: RFmxSpecAn_PAVTGetSegmentType
Set Function: RFmxSpecAn_PAVTSetSegmentType
Values:
RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_PHASE_AND_AMPLITUDE (0) Phase and amplitude is measured in this segment.
RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_AMPLITUDE (1) Amplitude is measured in this segment.
RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_FREQUENCY_ERROR_MEASUREMENT (2) Frequency error is measured in this segment.

RFMXSPECAN_ATTR_PAVT_SEGMENT_START_TIME

Data Type: float64
Access: read/write
Functions: RFmxSpecAn_SetAttributeF64
RFmxSpecAn_GetAttributeF64
Description: Specifies the start time of measurement of the segments. This value is expressed in seconds. You can use this attribute only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LOCATION_TYPE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_LOCATION_TYPE_TIME.

Use 'segment(n)' as the selector string to configure or read this attribute.

The default value is 0.

Get Function: RFmxSpecAn_PAVTGetSegmentStartTime
Set Function: RFmxSpecAn_PAVTSetSegmentStartTime

RFMXSPECAN_ATTR_PAVT_MEASUREMENT_OFFSET

Data Type: float64
Access: read/write
Functions: RFmxSpecAn_SetAttributeF64
RFmxSpecAn_GetAttributeF64
Description: Specifies the time offset from the start of the segment for which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is 0.

Get Function: RFmxSpecAn_PAVTGetMeasurementOffset
Set Function: RFmxSpecAn_PAVTSetMeasurementOffset

RFMXSPECAN_ATTR_PAVT_MEASUREMENT_LENGTH

Data Type: float64
Access: read/write
Functions: RFmxSpecAn_SetAttributeF64
RFmxSpecAn_GetAttributeF64
Description: Specifies the duration within the segment over which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_UNIFORM.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is 1 millisecond.

Get Function: RFmxSpecAn_PAVTGetMeasurementLength
Set Function: RFmxSpecAn_PAVTSetMeasurementLength

RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_OFFSET

Data Type: float64
Access: read/write
Functions: RFmxSpecAn_SetAttributeF64
RFmxSpecAn_GetAttributeF64
Description: Specifies the time offset from the start of the segment for which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid only when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_VARIABLE.

Use 'segment(n)' as the selector string to configure or read this attribute.

The default value is 0.

Get Function: RFmxSpecAn_PAVTGetSegmentMeasurementOffset
Set Function: RFmxSpecAn_PAVTSetSegmentMeasurementOffset

RFMXSPECAN_ATTR_PAVT_SEGMENT_MEASUREMENT_LENGTH

Data Type: float64
Access: read/write
Functions: RFmxSpecAn_SetAttributeF64
RFmxSpecAn_GetAttributeF64
Description: Specifies the duration within each segment over which the phase and amplitude, amplitude, or frequency error values are computed. This value is expressed in seconds. This attribute is valid when you set the RFMXSPECAN_ATTR_PAVT_MEASUREMENT_INTERVAL_MODE attribute to RFMXSPECAN_VAL_PAVT_MEASUREMENT_INTERVAL_MODE_VARIABLE.

Use 'segment(n)' as the selector string to configure or read this attribute.

The default value is 1 millisecond.

Get Function: RFmxSpecAn_PAVTGetSegmentMeasurementLength
Set Function: RFmxSpecAn_PAVTSetSegmentMeasurementLength

RFMXSPECAN_ATTR_PAVT_PHASE_UNWRAP_ENABLED

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies whether the phase measurement results are unwrapped or wrapped.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is RFMXSPECAN_VAL_PAVT_PHASE_UNWRAP_ENABLED_FALSE.

Get Function: RFmxSpecAn_PAVTGetPhaseUnwrapEnabled
Set Function: RFmxSpecAn_PAVTSetPhaseUnwrapEnabled
Values:
RFMXSPECAN_VAL_PAVT_PHASE_UNWRAP_ENABLED_FALSE (0) Phase measurement results are wrapped within +/-180 degrees.
RFMXSPECAN_VAL_PAVT_PHASE_UNWRAP_ENABLED_TRUE (1) Phase measurement results are unwrapped.

RFMXSPECAN_ATTR_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies whether to enable frequency offset correction for the measurement.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_FALSE.

Get Function: RFmxSpecAn_PAVTGetFrequencyOffsetCorrectionEnabled
Set Function: RFmxSpecAn_PAVTSetFrequencyOffsetCorrectionEnabled
Values:
RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_FALSE (0) Disables the frequency offset correction.
RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_TRUE (1) Enables the frequency offset correction. The measurement computes and corrects any frequency offset between the reference and the acquired waveforms.

RFMXSPECAN_ATTR_PAVT_FREQUENCY_TRACKING_ENABLED

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies whether to enable frequency offset correction per segment for the measurement. While you set this attribute to RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_TRUE, ensure that the RFMXSPECAN_ATTR_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED attribute is set to RFMXSPECAN_VAL_PAVT_FREQUENCY_OFFSET_CORRECTION_ENABLED_TRUE and the RFMXSPECAN_ATTR_PAVT_SEGMENT_TYPE attribute is set to RFMXSPECAN_VAL_PAVT_SEGMENT_TYPE_PHASE_AND_AMPLITUDE.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_FALSE.

Get Function: RFmxSpecAn_PAVTGetFrequencyTrackingEnabled
Set Function: RFmxSpecAn_PAVTSetFrequencyTrackingEnabled
Values:
RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_FALSE (0) Disables the drift correction for the measurement.
RFMXSPECAN_VAL_PAVT_FREQUENCY_TRACKING_ENABLED_TRUE (1) Enables the drift correction. The measurement corrects and reports the frequency offset per segment.

RFMXSPECAN_ATTR_PAVT_ALL_TRACES_ENABLED

Data Type: int32
Access: read/write
Functions: RFmxSpecAn_SetAttributeI32
RFmxSpecAn_GetAttributeI32
Description: Specifies whether to enable the traces to be stored and retrieved after performing the PAVT measurement.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is RFMXSPECAN_VAL_FALSE.

Get Function: RFmxSpecAn_PAVTGetAllTracesEnabled
Set Function: RFmxSpecAn_PAVTSetAllTracesEnabled

PAVT Results

RFMXSPECAN_ATTR_PAVT_RESULTS_MEAN_RELATIVE_PHASE

Data Type: float64
Access: read only
Functions: RFmxSpecAn_GetAttributeF64
Description: Returns the mean phase of the segment, relative to the phase of the reference segment. This value is expressed in degrees.



Use 'segment(n)' as the selector string to read this result.

Get Function: RFmxSpecAn_PAVTGetResultsMeanRelativePhase

RFMXSPECAN_ATTR_PAVT_RESULTS_MEAN_RELATIVE_AMPLITUDE

Data Type: float64
Access: read only
Functions: RFmxSpecAn_GetAttributeF64
Description: Returns the mean amplitude of the segment, relative to the amplitude of the reference segment. This value is expressed in dB.

Mean Relative Amplitude = ai - ar

ai is the absolute amplitude of the segment i, expressed in dBm

ar is the absolute amplitude of the reference segment r, expressed in dBm

where,

r = 1, if Segment0 is configured as Frequency Error Measurement segment

r = 0, otherwise

Use 'segment(n)' as the selector string to read this result.

Get Function: RFmxSpecAn_PAVTGetResultsMeanRelativeAmplitude

RFMXSPECAN_ATTR_PAVT_RESULTS_MEAN_ABSOLUTE_PHASE

Data Type: float64
Access: read only
Functions: RFmxSpecAn_GetAttributeF64
Description: Returns the mean absolute phase of the segment. This value is expressed in degrees.

Use 'segment(n)' as the selector string to read this result.

Get Function: RFmxSpecAn_PAVTGetResultsMeanAbsolutePhase

RFMXSPECAN_ATTR_PAVT_RESULTS_MEAN_ABSOLUTE_AMPLITUDE

Data Type: float64
Access: read only
Functions: RFmxSpecAn_GetAttributeF64
Description: Returns the mean absolute amplitude of the segment. This value is expressed in dBm.

Use 'segment(n)' as the selector string to read this result.

Get Function: RFmxSpecAn_PAVTGetResultsMeanAbsoluteAmplitude

RFMXSPECAN_ATTR_PAVT_RESULTS_FREQUENCY_ERROR_MEAN

Data Type: float64
Access: read only
Functions: RFmxSpecAn_GetAttributeF64
Description: Returns the mean frequency error of the segment. This value is expressed in Hz

Use 'segment(n)' as the selector string to read this result.

Get Function: RFmxSpecAn_PAVTGetResultsFrequencyErrorMean

Table of Contents

Internal Development

Creating and Setting Up a gRPC Server

Server Security Support

Creating a gRPC Client

gRPC Client Examples

Session Utilities API Reference

Driver Documentation

gRPC API Differences From C API

Sharing Driver Sessions Between Clients

C API Docs
NI-DAQmx
NI-DCPOWER
NI-DIGITAL PATTERN DRIVER
NI-DMM
NI-FGEN
NI-FPGA
NI-RFmx Bluetooth
NI-RFmx NR
NI-RFmx WCDMA
NI-RFmx GSM
NI-RFmx CDMA2k
NI-RFmx Instr
NI-RFmx LTE
NI-RFmx SpecAn
NI-RFmx TD-SCDMA
NI-RFmx WLAN
NI-RFSA
NI-RFSG
NI-SCOPE
NI-SWITCH
NI-TCLK
NI-XNET
Clone this wiki locally