tickets/DM-45261: Add description field to ATCalsys and MTCalsys schema validation files #168

Open
wants to merge 4 commits into
base: develop
Choose a base branch
from

Conversation

MarcoRocchietti
Copy link
Contributor

No description provided.

specified by the Power Line Cycle (PLC), where 1 PLC for 60Hz is
16.67msec. Fast integration=0.01PLC; Medium integration=0.1PLC; Normal
(default) integration = 1PLC; High Accuracy integration=10PLC. Here the
integration is set in seconds.
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Here I'm including a lot of information. I guess it could be more concise. Let me know if the extra paragraph should be summarized or removed. I have taken it from the command specification.


-1 for automatic range. Volts range from 0 to 210 Volts, Current range
from 0 to 21e-3 Amps, Resistance from 0 to 100e18 Ohms, Charge from 0 to
+2.1e-6 Coulombs.
type: number
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Again, it may have too much information. Let me know if it should be summarized.