Skip to content

ESP32 based MQTT gateway for the CN105 protocol based Mitsubishi Heat Pumps (FTC5)

Notifications You must be signed in to change notification settings

chriskearns/CN105Gateway

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

17 Commits
 
 
 
 
 
 
 
 

Repository files navigation

cn105gw

ESP32 based MQTT gateway for the CN105 protocol based Mitsubishi Heat Pumps (FTC5)

The code is developed to do the following things:

  • General

    • Pull all known information for the HP (Heat Pump) in a loop (about one's a minute)
    • Publish all know information using MQTT. Topic: cn105gw/tele
    • The information is JSON encoded payload: {"Zone 1 Flow Temp Setpoint":"32"})
    • Provide a logging output by telnet
  • Provide a webinterface for status of the gateway

    • You can set OTA enable/disble
    • Reboot the gateway
    • See the RSSI of the Wifi connection

Hardware used:

I use a Lolin32 development board, but any ESP32 development board should work. Besides the Lolin32 I use a level shifting board (5v from HP to 3.3V Lolin32) and a DC-DC convertor. The DC-DC converter is use to power the Lolon32 board from the 12V provided by the CN105 interface. I power the Lolin32 with 5V.

image

image

MQTT format

The gateway will send MQTT data in the following format:

  • Topic: cn105gw/tele/0x09 (0x09 indicates the command entry received from the Heat Pump)
  • Payload: {"Zone1_Room_Temp_Setpoint":"21.0","Zone2_Room_Temp_Setpoint":"23.0","Zone1_Flow_Temp_Setpoint":"32.0","Zone2_Flow_Temp_Setpoint":"31.0","Legionalla_Temp_Setpoint":"65.0","Flow_Temp_Range_Max":"35.0","Flow_Temp_Range_Min":"25.0"}

Last will and testament is implemented:

  • Topic: cn105gw/status
  • If online: Payload = "Online" else Payload = "Offline"

Setting parameters is done in this format:

  • Topic: cn105gw/cmnd
  • Payload (json encoded as strings): {"SetFlowTemperature":"33"}

Implemented settings:

All settings are done in Topic: cn105gw/cmnd

  • {"SetSystemModeOnOff":"1"}
    • 0=Standy
    • 1=On
  • {"SetHotWaterMode":"1"}
    • 0=Normal
    • 1=Eco
  • {"SetACMode":"1"}
    • 0=heating room mode
    • 1=heating flow temp
    • 2=heating heat curve
    • 3=cooling room tempmode
    • 4=cooling flow temp
    • 5=floor dryup
  • {"SetFlowTemperature":"XX"}
    • XX=Temperature (whole decimal)
  • {"SetBoilerTemperature":"XX"}
    • XX=Temperature (whole decimal)
  • {"SetRoomTemperature":"XX"}
    • XX=Temperature (whole decimal)
  • {"ForceDHW":"1"}
    • 1=ForceDHW
    • 0= Cancel/back Normal

With help of many on the internet.

Part of code from: https://github.com/SwiCago/HeatPump

Code/decode info: https://github.com/m000c400/Mitsubishi-CN105-Protocol-Decode

Unfortunatelly I am not a professional programmer so my code is hard to follow, not logical and will have many bugs