1 change: 1 addition & 0 deletions .gitignore
Original file line number Diff line number Diff line change
Expand Up @@ -4,3 +4,4 @@
dist/

modelicafmt
modelica-fmt
7 changes: 4 additions & 3 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -5,17 +5,18 @@ The Modelica Formatter provides the ability to automatically format Modelica cod
## Running

```bash
modelicafmt [-w] [-help] <sources>...
modelica-fmt [-w] [-help] <sources>...
Options:
-w overwrite source with formatted output. If flag is not present print to stdout
Arguments:
sources one or more files or directories to format
```

To run the example:
To run the examples:

```bash
./modelicafmt examples/gmt-building.mo > examples/gmt-building-out.mo
./modelica-fmt examples/gmt-building.mo > examples/gmt-building-out.mo
./modelica-fmt examples/gmt-coolingtower.mo > examples/gmt-coolingtower-out.mo
```

The resulting .mo file can be diffed to the previous file to compare how the modelica-fmt updates the file.
Expand Down
189 changes: 189 additions & 0 deletions examples/gmt-building-out.mo
Original file line number Diff line number Diff line change
@@ -0,0 +1,189 @@
// Model copied from GeoJSON to Modelica Translator project (https://github.com/urbanopt/geojson-modelica-translator)
within a_project.B5a6b99ec37f4de7f94020090;
model building
"n-zone RC building model based on URBANopt's use of TEASER export, with distribution pumps"
extends PartialBuilding(
redeclare package Medium=MediumW,
have_fan=false,
have_eleHea=false,
have_eleCoo=false);
package MediumW=Buildings.Media.Water
"Source side medium";
package MediumA=Buildings.Media.Air
"Load side medium";
parameter Integer nZon=6
"Number of thermal zones";
parameter Integer facSca=3
"Scaling factor to be applied to on each extensive quantity";
parameter Modelica.SIunits.TemperatureDifference delTBuiCoo=5
"Nominal building supply and return chilled water temperature difference";
Buildings.Controls.OBC.CDL.Continuous.Sources.Constant minTSet[nZon](
k=fill(
293.15,
nZon),
y(
each final unit="K",
each displayUnit="degC"))
"Minimum temperature set point"
annotation (Placement(transformation(extent={{-290, 230}, {-270, 250}})));
Buildings.Controls.OBC.CDL.Continuous.Sources.Constant maxTSet[nZon](
k=fill(
297.15,
nZon),
y(
each final unit="K",
each displayUnit="degC"))
"Maximum temperature set point"
annotation (Placement(transformation(extent={{-290, 190}, {-270, 210}})));
Meeting meeting
annotation (Placement(transformation(extent={{-160,-20}, {-140, 0}})));
Floor floor
annotation (Placement(transformation(extent={{-120,-20}, {-100, 0}})));
Storage storage
annotation (Placement(transformation(extent={{-80,-20}, {-60, 0}})));
Office office
annotation (Placement(transformation(extent={{-40,-20}, {-20, 0}})));
Restroom restroom
annotation (Placement(transformation(extent={{0,-20}, {20, 0}})));
ICT ict
annotation (Placement(transformation(extent={{40,-20}, {60, 0}})));
Buildings.Controls.OBC.CDL.Continuous.MultiSum mulSum(
nin=2) if have_pum
annotation (Placement(transformation(extent={{260, 70}, {280, 90}})));
Buildings.Applications.DHC.Loads.Examples.BaseClasses.FanCoil4PipeHeatPorts terUni[nZon](
redeclare each package Medium1=MediumW,
redeclare each package Medium2=MediumA,
each facSca=facSca,
QHea_flow_nominal={10000, 10000, 10000, 10000, 10000, 10000},
QCoo_flow_nominal={-10000,-10000,-10000,-10000,-10000,-50000},
each T_aLoaHea_nominal=293.15,
each T_aLoaCoo_nominal=297.15,
each T_bHeaWat_nominal=35+273.15,
each T_bChiWat_nominal=12+273.15,
each T_aHeaWat_nominal=40+273.15,
each T_aChiWat_nominal=7+273.15,
each mLoaHea_flow_nominal=5,
each mLoaCoo_flow_nominal=5)
"Terminal unit"
annotation (Placement(transformation(extent={{-200,-60}, {-180,-40}})));
Buildings.Applications.DHC.Loads.BaseClasses.FlowDistribution disFloHea(
redeclare package Medium=MediumW,
m_flow_nominal=sum(
terUni.mHeaWat_flow_nominal .* terUni.facSca),
dp_nominal(
displayUnit="Pa")=100000,
have_pum=have_pum,
nPorts_a1=nZon,
nPorts_b1=nZon)
"Heating water distribution system"
annotation (Placement(transformation(extent={{-140,-100}, {-120,-80}})));
Buildings.Applications.DHC.Loads.BaseClasses.FlowDistribution disFloCoo(
redeclare package Medium=MediumW,
m_flow_nominal=sum(
terUni.mChiWat_flow_nominal .* terUni.facSca),
typDis=Buildings.Applications.DHC.Loads.Types.DistributionType.ChilledWater,
dp_nominal(
displayUnit="Pa")=100000,
have_pum=have_pum,
nPorts_a1=nZon,
nPorts_b1=nZon)
"Chilled water distribution system"
annotation (Placement(transformation(extent={{-140,-160}, {-120,-140}})));
equation
connect(disFloHea.port_b, secHeaRet[1])
annotation (Line(points={{140,-70}, {240,-70}, {240, 32}, {300, 32}}, color={0, 127, 255}));
connect(disFloHea.port_a, secHeaSup[1])
annotation (Line(points={{120,-70}, {-242,-70}, {-242, 32}, {-300, 32}}, color={0, 127, 255}));
connect(disFloCoo.port_b, secCooRet[1])
annotation (Line(points={{140,-110}, {252,-110}, {252,-30}, {300,-30}}, color={0, 127, 255}));
connect(disFloCoo.port_a, secCooSup[1])
annotation (Line(points={{120,-110}, {-280,-110}, {-280,-30}, {-300,-30}}, color={0, 127, 255}));
connect(disFloHea.ports_a1, terUni.port_bHeaWat)
annotation (Line(points={{-120,-80.6667}, {-104,-80.6667}, {-104,-58.3333}, {-180,-58.3333}}, color={0, 127, 255}));
connect(disFloHea.ports_b1, terUni.port_aHeaWat)
annotation (Line(points={{-140,-80.6667}, {-216,-80.6667}, {-216,-58.3333}, {-200,-58.3333}}, color={0, 127, 255}));
connect(disFloCoo.ports_a1, terUni.port_bChiWat)
annotation (Line(points={{-120,-144}, {-94,-144}, {-94,-56}, {-180,-56}, {-180,-56.6667}}, color={0, 127, 255}));
connect(disFloCoo.ports_b1, terUni.port_aChiWat)
annotation (Line(points={{-140,-144}, {-226,-144}, {-226,-56.6667}, {-200,-56.6667}}, color={0, 127, 255}));
connect(weaBus, meeting.weaBus)
annotation (Line(points={{1, 300}, {0, 300}, {0, 20}, {-66, 20}, {-66,-10.2}, {-96,-10.2}}, color={255, 204, 51}, thickness=0.5), Text(string="%first", index=-1, extent={{6, 3}, {6, 3}}, horizontalAlignment=TextAlignment.Left));
connect(terUni[0+1].heaPorCon, meeting.port_a)
annotation (Line(points={{-193.333,-50}, {-192,-50}, {-192, 0}, {-90, 0}}, color={191, 0, 0}));
connect(terUni[0+1].heaPorRad, meeting.port_a)
annotation (Line(points={{-186.667,-50}, {-90,-50}, {-90, 0}}, color={191, 0, 0}));
connect(weaBus, floor.weaBus)
annotation (Line(points={{1, 300}, {0, 300}, {0, 20}, {-66, 20}, {-66,-10.2}, {-96,-10.2}}, color={255, 204, 51}, thickness=0.5), Text(string="%first", index=-1, extent={{6, 3}, {6, 3}}, horizontalAlignment=TextAlignment.Left));
connect(terUni[1+1].heaPorCon, floor.port_a)
annotation (Line(points={{-193.333,-50}, {-192,-50}, {-192, 0}, {-90, 0}}, color={191, 0, 0}));
connect(terUni[1+1].heaPorRad, floor.port_a)
annotation (Line(points={{-186.667,-50}, {-90,-50}, {-90, 0}}, color={191, 0, 0}));
connect(weaBus, storage.weaBus)
annotation (Line(points={{1, 300}, {0, 300}, {0, 20}, {-66, 20}, {-66,-10.2}, {-96,-10.2}}, color={255, 204, 51}, thickness=0.5), Text(string="%first", index=-1, extent={{6, 3}, {6, 3}}, horizontalAlignment=TextAlignment.Left));
connect(terUni[2+1].heaPorCon, storage.port_a)
annotation (Line(points={{-193.333,-50}, {-192,-50}, {-192, 0}, {-90, 0}}, color={191, 0, 0}));
connect(terUni[2+1].heaPorRad, storage.port_a)
annotation (Line(points={{-186.667,-50}, {-90,-50}, {-90, 0}}, color={191, 0, 0}));
connect(weaBus, office.weaBus)
annotation (Line(points={{1, 300}, {0, 300}, {0, 20}, {-66, 20}, {-66,-10.2}, {-96,-10.2}}, color={255, 204, 51}, thickness=0.5), Text(string="%first", index=-1, extent={{6, 3}, {6, 3}}, horizontalAlignment=TextAlignment.Left));
connect(terUni[3+1].heaPorCon, office.port_a)
annotation (Line(points={{-193.333,-50}, {-192,-50}, {-192, 0}, {-90, 0}}, color={191, 0, 0}));
connect(terUni[3+1].heaPorRad, office.port_a)
annotation (Line(points={{-186.667,-50}, {-90,-50}, {-90, 0}}, color={191, 0, 0}));
connect(weaBus, restroom.weaBus)
annotation (Line(points={{1, 300}, {0, 300}, {0, 20}, {-66, 20}, {-66,-10.2}, {-96,-10.2}}, color={255, 204, 51}, thickness=0.5), Text(string="%first", index=-1, extent={{6, 3}, {6, 3}}, horizontalAlignment=TextAlignment.Left));
connect(terUni[4+1].heaPorCon, restroom.port_a)
annotation (Line(points={{-193.333,-50}, {-192,-50}, {-192, 0}, {-90, 0}}, color={191, 0, 0}));
connect(terUni[4+1].heaPorRad, restroom.port_a)
annotation (Line(points={{-186.667,-50}, {-90,-50}, {-90, 0}}, color={191, 0, 0}));
connect(weaBus, ict.weaBus)
annotation (Line(points={{1, 300}, {0, 300}, {0, 20}, {-66, 20}, {-66,-10.2}, {-96,-10.2}}, color={255, 204, 51}, thickness=0.5), Text(string="%first", index=-1, extent={{6, 3}, {6, 3}}, horizontalAlignment=TextAlignment.Left));
connect(terUni[5+1].heaPorCon, ict.port_a)
annotation (Line(points={{-193.333,-50}, {-192,-50}, {-192, 0}, {-90, 0}}, color={191, 0, 0}));
connect(terUni[5+1].heaPorRad, ict.port_a)
annotation (Line(points={{-186.667,-50}, {-90,-50}, {-90, 0}}, color={191, 0, 0}));
connect(terUni.mReqHeaWat_flow, disFloHea.mReq_flow)
annotation (Line(points={{-179.167,-53.3333}, {-179.167,-54}, {-170,-54}, {-170,-94}, {-141,-94}}, color={0, 0, 127}));
connect(terUni.mReqChiWat_flow, disFloCoo.mReq_flow)
annotation (Line(points={{-179.167,-55}, {-179.167,-56}, {-172,-56}, {-172,-154}, {-141,-154}}, color={0, 0, 127}));
connect(mulSum.y, PPum)
annotation (Line(points={{282, 80}, {320, 80}}, color={0, 0, 127}));
connect(disFloHea.PPum, mulSum.u[1])
annotation (Line(points={{-119,-98}, {240,-98}, {240, 81}, {258, 81}}, color={0, 0, 127}));
connect(disFloCoo.PPum, mulSum.u[2])
annotation (Line(points={{-119,-158}, {240,-158}, {240, 79}, {258, 79}}, color={0, 0, 127}));
connect(disFloHea.QActTot_flow, QHea_flow)
annotation (Line(points={{-119,-96}, {223.5,-96}, {223.5, 280}, {320, 280}}, color={0, 0, 127}));
connect(disFloCoo.QActTot_flow, QCoo_flow)
annotation (Line(points={{-119,-156}, {230,-156}, {230, 240}, {320, 240}}, color={0, 0, 127}));
connect(maxTSet.y, terUni.TSetCoo)
annotation (Line(points={{-268, 200}, {-240, 200}, {-240,-46.6667}, {-200.833,-46.6667}}, color={0, 0, 127}));
connect(minTSet.y, terUni.TSetHea)
annotation (Line(points={{-268, 240}, {-220, 240}, {-220,-45}, {-200.833,-45}}, color={0, 0, 127}));
annotation (
Documentation(
info="
<html>
<p>
Building wrapper for running n-zone thermal zone models generated by TEASER.
The heating and cooling loads are computed with a four-pipe
fan coil unit model derived from
<a href=\"modelica://Buildings.Applications.DHC.Loads.BaseClasses.PartialTerminalUnit\">
Buildings.Applications.DHC.Loads.BaseClasses.PartialTerminalUnit</a>
and connected to the room model by means of heat ports.
</p>
</html>",
revisions="<html>
<ul>
<li>
May 29, 2020, by Nicholas Long:<br/>
Template model for use in GeoJSON to Modelica Translator.
</li>
<li>
February 21, 2020, by Antoine Gautier:<br/>
First implementation.
</li>
</ul>
</html>"));
end building;
4 changes: 2 additions & 2 deletions examples/gmt-building.mo
Original file line number Diff line number Diff line change
@@ -1,3 +1,4 @@
// Model copied from GeoJSON to Modelica Translator project (https://github.com/urbanopt/geojson-modelica-translator)
within a_project.B5a6b99ec37f4de7f94020090;
model building
"n-zone RC building model based on URBANopt's use of TEASER export, with distribution pumps"
Expand All @@ -15,8 +16,7 @@ model building
"Nominal building supply and return chilled water temperature difference";

Buildings.Controls.OBC.CDL.Continuous.Sources.Constant minTSet[nZon](
k=fill(293.15, nZon),
y(each final unit="K", each displayUnit="degC"))
k=fill(293.15, nZon), y(each final unit="K", each displayUnit="degC"))
"Minimum temperature set point"

annotation (Placement(transformation(extent={{-290,230},{-270,250}})));