Revert "scsi: mpi3mr: Sanitise num_phys" #195
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
It seems to cause probe failures on 9600-16e HBAs with at least ES60G2/G3 JBODs due to PHY numbers not only above 32, but actually even above 64, as bumped in Linux master. Until upstream developers provide anything better, I expect this to get us back where we were with DF, despite being imperfect.