Skip to content

Commit

Permalink
Added option to disable third-party PCIe card default cooling response (
Browse files Browse the repository at this point in the history
  • Loading branch information
louispires authored Feb 2, 2023
1 parent 857a3b3 commit f1c47b0
Show file tree
Hide file tree
Showing 3 changed files with 51 additions and 5 deletions.
50 changes: 45 additions & 5 deletions Dell_iDRAC_fan_controller.sh
Original file line number Diff line number Diff line change
@@ -1,20 +1,48 @@
#!/bin/bash

# Define global functions
apply_Dell_profile () {
function apply_Dell_profile () {
ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x01 0x01 > /dev/null
CURRENT_FAN_CONTROL_PROFILE="Dell default dynamic fan control profile"
}

apply_user_profile () {
function apply_user_profile () {
ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x01 0x00 > /dev/null
ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x02 0xff $HEXADECIMAL_FAN_SPEED > /dev/null
CURRENT_FAN_CONTROL_PROFILE="User static fan control profile ($DECIMAL_FAN_SPEED%)"
}

function enable_third_party_PCIe_card_Dell_default_cooling_response () {
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
ipmitool -I $LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
}

function disable_third_party_PCIe_card_Dell_default_cooling_response () {
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
ipmitool -I $LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
}

# Returns :
# - 0 if third-party PCIe card Dell default cooling response is currently DISABLED
# - 1 if third-party PCIe card Dell default cooling response is currently ENABLED
# - 2 if the current status returned by ipmitool command output is unexpected
# function is_third_party_PCIe_card_Dell_default_cooling_response_disabled() {
# THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE=$(ipmitool -I $LOGIN_STRING raw 0x30 0xce 0x01 0x16 0x05 0x00 0x00 0x00)

# if [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 01 00 00" ]; then
# return 0
# elif [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 00 00 00" ]; then
# return 1
# else
# echo "Unexpected output: $THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" >&2
# return 2
# fi
# }

# Prepare traps in case of container exit
gracefull_exit () {
function gracefull_exit () {
apply_Dell_profile
enable_third_party_PCIe_card_Dell_default_cooling_response
echo "/!\ WARNING /!\ Container stopped, Dell default dynamic fan control profile applied for safety."
exit 0
}
Expand Down Expand Up @@ -49,6 +77,7 @@ echo "CPU temperature treshold: $CPU_TEMPERATURE_TRESHOLD°C"
echo "Check interval: ${CHECK_INTERVAL}s"
echo ""

# Prepare required variables and constants
readonly TABLE_HEADER_PRINT_INTERVAL=10
i=$TABLE_HEADER_PRINT_INTERVAL
IS_DELL_PROFILE_APPLIED=true
Expand Down Expand Up @@ -103,14 +132,25 @@ while true; do
fi
fi

# Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response
# No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container
if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE
then
disable_third_party_PCIe_card_Dell_default_cooling_response
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled"
else
enable_third_party_PCIe_card_Dell_default_cooling_response
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled"
fi

# Print temperatures array
if [ $i -ge $TABLE_HEADER_PRINT_INTERVAL ]
then
echo " ------- Temperatures -------"
echo " Date & time Inlet CPU 1 CPU 2 Exhaust Active fan speed profile Comment"
echo " Date & time Inlet CPU 1 CPU 2 Exhaust Active fan speed profile Third-party PCIe card Dell default cooling response Comment"
i=0
fi
printf "%12s %3d°C %3d°C %3d°C %5d°C %40s %s\n" "$(date +"%d-%m-%y %H:%M:%S")" $INLET_TEMPERATURE $CPU1_TEMPERATURE $CPU2_TEMPERATURE $EXHAUST_TEMPERATURE "$CURRENT_FAN_CONTROL_PROFILE" "$COMMENT"
printf "%12s %3d°C %3d°C %3d°C %5d°C %40s %51s %s\n" "$(date +"%d-%m-%y %H:%M:%S")" $INLET_TEMPERATURE $CPU1_TEMPERATURE $CPU2_TEMPERATURE $EXHAUST_TEMPERATURE "$CURRENT_FAN_CONTROL_PROFILE" "$THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS" "$COMMENT"

((i++))
wait $SLEEP_PROCESS_PID
Expand Down
1 change: 1 addition & 0 deletions Dockerfile
Original file line number Diff line number Diff line change
Expand Up @@ -18,5 +18,6 @@ ENV IDRAC_HOST local
ENV FAN_SPEED 5
ENV CPU_TEMPERATURE_TRESHOLD 50
ENV CHECK_INTERVAL 60
ENV DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE false

CMD ["/Dell_iDRAC_fan_controller.sh"]
5 changes: 5 additions & 0 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -61,6 +61,7 @@ docker run -d \
-e FAN_SPEED=<decimal or hexadecimal fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \
-e CHECK_INTERVAL=<seconds between each check> \
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \
--device=/dev/ipmi0:/dev/ipmi0:rw \
tigerblue77/dell_idrac_fan_controller:latest
```
Expand All @@ -77,6 +78,7 @@ docker run -d \
-e FAN_SPEED=<decimal or hexadecimal fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \
-e CHECK_INTERVAL=<seconds between each check> \
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \
tigerblue77/dell_idrac_fan_controller:latest
```

Expand All @@ -97,6 +99,7 @@ services:
- FAN_SPEED=<decimal or hexadecimal fan speed>
- CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold>
- CHECK_INTERVAL=<seconds between each check>
- DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false>
devices:
- /dev/ipmi0:/dev/ipmi0:rw
```
Expand All @@ -118,6 +121,7 @@ services:
- FAN_SPEED=<decimal or hexadecimal fan speed>
- CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold>
- CHECK_INTERVAL=<seconds between each check>
- DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false>
```
<p align="right">(<a href="#top">back to top</a>)</p>
Expand All @@ -133,6 +137,7 @@ All parameters are optional as they have default values (including default iDRAC
- `FAN_SPEED` parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. **Default** value is 5(%).
- `CPU_TEMPERATURE_TRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C).
- `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s).
- `DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE` parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. **Default** value is false.

<p align="right">(<a href="#top">back to top</a>)</p>

Expand Down

0 comments on commit f1c47b0

Please sign in to comment.