Original file line number Diff line number Diff line change
Expand Up @@ -20,6 +20,34 @@ https://hub.docker.com/repository/docker/tigerblue77/dell_idrac_fan_controller

<p align="right">(<a href="#top">back to top</a>)</p>

<!-- PREREQUISITES -->
## Prerequisites
### To access iDRAC over LAN (not needed in "local" mode) :

1. Log into your iDRAC web console

![001](https://user-images.githubusercontent.com/37409593/210168273-7d760e47-143e-4a6e-aca7-45b483024139.png)

2. In the left side menu, expand "iDRAC settings", click "Network" then click "IPMI Settings" link at the top of the web page.

![002](https://user-images.githubusercontent.com/37409593/210168249-994f29cc-ac9e-4667-84f7-07f6d9a87522.png)

3. Check the "Enable IPMI over LAN" checkbox then click "Apply" button.

![003](https://user-images.githubusercontent.com/37409593/210168248-a68982c4-9fe7-40e7-8b2c-b3f06fbfee62.png)

4. Test access to IPMI over LAN running the following commands :
```bash
apt -y install ipmitool
ipmitool -I lanplus \
-H <iDRAC IP address> \
-U <iDRAC username> \
-P <iDRAC password> \
sdr elist all
```

<p align="right">(<a href="#top">back to top</a>)</p>

<!-- USAGE -->
## Usage

Expand All @@ -30,8 +58,8 @@ docker run -d \
--name Dell_iDRAC_fan_controller \
--restart=unless-stopped \
-e IDRAC_HOST=local \
-e FAN_SPEED=<dec or hex fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<dec temperature treshold> \
-e FAN_SPEED=<decimal or hexadecimal fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \
-e CHECK_INTERVAL=<seconds between each check> \
--device=/dev/ipmi0:/dev/ipmi0:rw \
tigerblue77/dell_idrac_fan_controller:latest
Expand All @@ -43,11 +71,11 @@ docker run -d \
docker run -d \
--name Dell_iDRAC_fan_controller \
--restart=unless-stopped \
-e IDRAC_HOST=<iDRAC host IP> \
-e IDRAC_HOST=<iDRAC IP address> \
-e IDRAC_USERNAME=<iDRAC username> \
-e IDRAC_PASSWORD=<iDRAC password> \
-e FAN_SPEED=<dec or hex fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<dec temperature treshold> \
-e FAN_SPEED=<decimal or hexadecimal fan speed> \
-e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \
-e CHECK_INTERVAL=<seconds between each check> \
tigerblue77/dell_idrac_fan_controller:latest
```
Expand All @@ -66,8 +94,8 @@ services:
restart: unless-stopped
environment:
- IDRAC_HOST=local
- FAN_SPEED=<dec or hex fan speed>
- CPU_TEMPERATURE_TRESHOLD=<dec temperature treshold>
- FAN_SPEED=<decimal or hexadecimal fan speed>
- CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold>
- CHECK_INTERVAL=<seconds between each check>
devices:
- /dev/ipmi0:/dev/ipmi0:rw
Expand All @@ -87,8 +115,8 @@ services:
- IDRAC_HOST=<iDRAC IP address>
- IDRAC_USERNAME=<iDRAC username>
- IDRAC_PASSWORD=<iDRAC password>
- FAN_SPEED=<dec or hex fan speed>
- CPU_TEMPERATURE_TRESHOLD=<dec temperature treshold>
- FAN_SPEED=<decimal or hexadecimal fan speed>
- CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold>
- CHECK_INTERVAL=<seconds between each check>
```
Expand All @@ -102,7 +130,7 @@ All parameters are optional as they have default values (including default iDRAC
- `IDRAC_HOST` parameter can be set to "local" or to your distant iDRAC's IP address. **Default** value is "local".
- `IDRAC_USERNAME` parameter is only necessary if you're adressing a distant iDRAC. **Default** value is "root".
- `IDRAC_PASSWORD` parameter is only necessary if you're adressing a distant iDRAC. **Default** value is "calvin".
- `FAN_SPEED` parameter can be set as a decimal (from 0 to 100%) or hexadecimal value (from 0x00 to 0x64) you want to set the fans to. **Default** value is 5(%).
- `FAN_SPEED` parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. **Default** value is 5(%).
- `CPU_TEMPERATURE_TRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C).
- `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s).