Note: This Binding is available in 1.8 SNAPSHOT and later releases.
This binding makes use of the CAN over Ethernet feature of the CMI from Technische Alternative. Since I only have the new UVR16x2, it has only been tested with this controller.
The binding currently supports the following functions:
- Receive data from analog outputs defined in TAPPS2
- Receive data from digital outputs defined in TAPPS2
- Send ON/OFF to digital inputs defined in TAPPS2
- Send DecimalType values to analog inputs defined in TAPPS 2
The configuration consists of the following steps:
- Copy the binding into your addons folder
- Configure the binding in openhab.cfg
- Configure CAN outputs in TAPPS2
- Configure your CMI for COE
- Add items to your Openhab configurations
Simply copy the jar file into your addons directory.
The binding has only 2 configuration parameters that need to be set in openhab.cfg
############################## TACmi Binding ##############################
#
# Refresh interval in milliseconds (optional, defaults to 300000)
tacmi:refresh=20
# IP or hostname of the CMI device
tacmi:cmiAddress=10.10.10.10
The refresh interval should be very small. The execute method of the binding blocks for new messages coming in for 10 seconds. If nothing has been received then the method is being restarted after the refresh interval has passed. If new data has been received then the first message is processed and the method is being restarted after the interval has passed. Messages are being processed one by one. Therefore, if you receive multiple message from the CMI, which is most likely the case, it always waits for the time configured in the refresh interval, before it processes the next one. The CMI uses port 5441 for sending and receiving UDP packets.
You need to configure CAN outputs in your Functional data on the UVR16x2. This can be done by using the TAPPS2 application from TA. Follow the user guide on how to do this.
Now follow the User Guide of the CMI on how to setup CAN over Ethernet (COE). Here you will map your outputs that you configured in the previous step. As the target device you need to put the IP of your OpenHAB server into the coe.csv. Don’t forget to reboot the CMI after you uploaded the coe.csv file.
Now you are ready to configure your items in OpenHAB. The syntax is as follows:
{tacmi="50#a#10#Temperature"}
- 50 = Target CAN Node as configured in the coe.csv file before
- a = analog output
- 10 = Number of the output as configured in TAPPS2
- Temperature = Measure Type of the analog value, currently only Temperature ans Seconds are supported
Example item:
Number TOelKessel "Kessel Temperatur [%.1f]" <heating> (Temperature, Heating_Chart) {tacmi="50#a#10#Temperature"}
{tacmi="50#d#5"}
- 50 = Target CAN Node as configured in coe.csv file before
- d = digital output
- 5 = Number of the output as configured in TAPPS2
Example item:
Switch Brenner "Brenner Anforderung" {tacmi="50#d#5"}
There was a bug in the CMI that messed up the UDP messages sent for analog outputs. As a workaround do not use the outputs 4, 8, 12, 16 and 17-32 in TAPPS2. The bug might have been fixed with recent updates of the CMI. This has not been tested though.
When defining an item that is being used as a digital input in your TAPPS2 then the binding only supports to use Digital Input 1. This is due to the way the COE protocol works as all 16 digital ports are being send within one message.
For Analog Inputs it is only possible to use Analog Inputs 1, 5, 9, 13 in TAPPS2. This is also due to the way COE works as for analog messages it will send then in bundles of 4. You can however use multiple CAN nodes. According to TAPPS2 you can use CAN nodes from 1-64. So if you only have one UVR and the CMI then you should have 62 nodes available for use. I would not use the same item for sending and receiving even though that should be possible of you use one of the supported ports. Instead I would use separate items and then use rules to get the functionality that you want to achieve. That way it should be possible to have a switch item that is being updated by a CAN output and when you send a command to it, then it uses a different item with a different CAN node that maps to a CAN Input in TAPPS2. I have not tried this though yet.
###Linux / OS X
###Windows
- Cosm Persistence
- db4o Persistence
- Exec Persistence
- InfluxDB Persistence
- JDBC Persistence
- JPA Persistence
- Logging Persistence
- mapdb Persistence
- MongoDB Persistence
- MQTT Persistence
- my.openHAB Persistence
- MySQL Persistence
- rrd4j Persistence
- Sen.Se Persistence
- SiteWhere Persistence
- AlarmDecoder Binding
- Anel Binding
- Arduino SmartHome Souliss Binding
- Asterisk Binding
- Astro Binding
- Autelis Pool Control Binding
- BenQ Projector Binding
- Bluetooth Binding
- Bticino Binding
- CalDAV Binding
- Comfo Air Binding
- Config Admin Binding
- CUL Binding
- CUL Intertechno Binding
- CUPS Binding
- DAIKIN Binding
- Davis Binding
- Denon Binding
- digitalSTROM Binding
- DMX512 Binding
- DSC Alarm Binding
- DSMR Binding
- eBUS Binding
- Ecobee Binding
- EDS OWSever Binding
- eKey Binding
- Energenie Binding
- EnOcean Binding
- Enphase Energy Binding
- Epson Projector Binding
- Exec Binding
- Freebox Binding
- Freeswitch Binding
- Frontier Silicon Radio Binding
- Fritz AHA Binding
- Fritz!Box Binding
- FS20 Binding
- Global Cache IR Binding
- GPIO Binding
- HAI/Leviton OmniLink Binding
- HDAnywhere Binding
- Heatmiser Binding
- Homematic / Homegear Binding
- HTTP Binding
- IEC 62056-21 Binding
- IHC / ELKO Binding
- ImperiHome Binding
- Insteon Hub Binding
- Insteon PLM Binding
- IPX800 Binding
- IRtrans Binding
- jointSPACE-Binding
- KNX Binding
- Koubachi Binding
- LCN Binding
- LightwaveRF Binding
- Leviton/HAI Omnilink Binding
- Lg TV Binding
- Logitech Harmony Hub
- MailControl Binding
- MAX!Cube-Binding
- MAX! CUL Binding
- MiLight Binding
- MiOS Binding
- Modbus TCP Binding
- MPD Binding
- MQTT Binding
- MQTTitude binding
- Neohub Binding
- Nest Binding
- Netatmo Binding
- Network Health Binding
- Network UPS Tools Binding
- Nibe Heatpump Binding
- Nikobus Binding
- Novelan/Luxtronic Heatpump Binding
- NTP Binding
- One-Wire Binding
- Onkyo AV Receiver Binding
- Open Energy Monitor Binding
- OpenPaths presence detection binding
- OpenSprinkler Binding
- OSGi Configuration Admin Binding
- Panasonic TV Bindung
- panStamp Binding
- Philips Hue Binding
- Piface Binding
- pilight Binding
- Pioneer-AVR-Binding
- Plex Binding
- Plugwise Binding
- PLCBus Binding
- Primare Binding
- Pulseaudio Binding
- RFXCOM Binding
- RWE Smarthome Binding
- Sager WeatherCaster Binding
- Samsung AC Binding
- Samsung TV Binding
- Serial Binding
- Sallegra Binding
- Satel Alarm Binding
- Sinthesi Sapp Binding
- Snmp Binding
- Somfy URTSI II Binding
- Sonos Binding
- Squeezebox Binding
- Swegon ventilation Binding
- System Info Binding
- TA CMI Binding
- TCP/UDP Binding
- Tellstick Binding
- TinkerForge Binding
- Tivo Binding
- VDR Binding
- Velleman-K8055-Binding
- Wago Binding
- Wake-on-LAN Binding
- Waterkotte EcoTouch Heatpump Binding
- Weather Binding
- Wemo Binding
- Withings Binding
- XBMC Binding
- xPL Binding
- Yamahareceiver Binding
- Zibase Binding
- Z-Wave Binding
- Asterisk
- Google Calendar
- Linux Media Players
- ROS Robot Operating System
- Telldus Tellstick
- Zoneminder
- Wink Hub (rooted)
- Wink Monitoring
- Transformations
- XSLT
- JSON
- REST-API
- Security
- Service Discovery
- Voice Control
- BritishGasHive-Using-Ruby
- Dropbox Bundle
A good source of inspiration and tips from users gathered over the years. Be aware that things may have changed since they were written and some examples might not work correctly.
Please update the wiki if you do come across any out of date information.
- Comfo Air Binding
- Ecobee Examples
- Nest Examples
- Rollershutter Bindings
- Squeezebox
- WAC Binding
- WebSolarLog
- Alarm Clock
- Convert Farenheit to Celcius
- The mother of all lighting rules
- Reusable Rules via Functions
- Combining different Items
- Items, Rules and more Examples of a SmartHome
- Google Map
- Controlling openHAB with Android
- Usecase examples
- B-Control Manager
- Spell checking for foreign languages
- Flic via Tasker
- Chromecast via castnow