Describe and provide kludge for mangled Canon DICOMs (#495)
Browse files Browse the repository at this point in the history
  • Loading branch information
neurolabusc committed Mar 17, 2021
1 parent e9eda83 commit 93e1373
Show file tree
Hide file tree
Showing 6 changed files with 37 additions and 29 deletions.
4 changes: 4 additions & 0 deletions Canon/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,10 @@

dcm2niix can convert Canon (né Toshiba) DICOM format images to NIfTI. This page notes vendor specific conversion details.

## Avoid Classic DICOM

Users of Canon MRI equipment are strongly advised to export data from their scanners as enhanced DICOM (with all images from the series stored as a single file) rather than classic DICOM (each 2D slice stored as a separate file). Limitations of the Canon classic DICOMs are described [here](https://github.com/rordenlab/dcm2niix/issues/495) and [here](https://github.com/neurolabusc/dcm_qa_canon).

## Diffusion Weighted Imaging Notes

In contrast to several other vendors, Toshiba used public tags to report diffusion properties. Specifically, [DiffusionBValue (0018,9087)](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0018,9087)) and [DiffusionGradientOrientation (0018,9089)](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0018,9089)). Be aware that these tags are only populated for images where a diffusion gradient is applied. Consider a typical diffusion series where some volumes are acquired with B=0 while others have B=1000. In this case, only the volumes with B>0 will report a DiffusionBValue. These coordinates are with respect to the scanner bore, not image space.
Expand Down
39 changes: 17 additions & 22 deletions Philips/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -18,13 +18,11 @@ Therefore, dcm2niix will ignore the IPP enclosed in 2005,140F unless no alternat

## Image Scaling

How data is represented in DICOM for MR has several challenges and the technology and standard has evolved over the years to accommodate new uses. Unlike CT, where the signal is naturally displayed in Hounsfield units, MR has no natural signal units and the magnitude is influenced by the electronics and the software processing required to bring this to the final image. Secondly most of the original DICOM implementations used small bit number integers to store the underlying images for economy of storage. As a result it is necessary to apply scaling from the internal DICOM storage to a form suitable for radiographic display or quantitative measurement. There remain several challenges with this process, ensuring that the mapping to the integer values makes best use of the available bit depth for images with large dynamic range, or large changes between images, without clipping the data while also preserving the appearance of the noise field which is demanded by the needs of radiographic visual review.
How data is represented in DICOM for MR has several challenges and the technology and standard has evolved over the years to accommodate new uses. Unlike CT, where the signal is naturally displayed in Hounsfield units, MR has no natural signal units and the magnitude is influenced by the electronics and the software processing required to bring this to the final image. Secondly most of the original DICOM implementations used small bit number integers to store the underlying images for economy of storage. As a result it is necessary to apply scaling from the internal DICOM storage to a form suitable for radiographic display or quantitative measurement. There remain several challenges with this process, ensuring that the mapping to the integer values makes best use of the available bit depth for images with large dynamic range, or large changes between images, without clipping the data while also preserving the appearance of the noise field which is demanded by the needs of radiographic visual review. Note that for most MRI modalities these concerns do not impact analyses: the intensity is assumed arbitrary, the statistics treat signal offset and scaling as nuisance regressors when fitting models, and cacluations are computed with high precision floating point numbers. However, there are some situations such as arterial spin labeling where image scaling is important. In these situations, scaling is a crucial aspect to be aware of for quantitative methods and which representation is used depends upon your needs.

At its simplest this requires a rescale slope and intercept defined by the DICOM standard tags [0028,1053](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0028,1053)) and [0028,1052](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0028,1053)). Whether these values are the same for all images, or image specific depends upon the implementation and potentially the location of these tags withing the DICOM tag structure.
At its simplest image scaling requires a rescale slope and intercept defined by the DICOM standard tags [0028,1053](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0028,1053)) and [0028,1052](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0028,1053)). Whether these values are the same for all images, or image specific depends upon the implementation and potentially the location of these tags withing the DICOM tag structure. For manufacturers other than Philips, these are the only intensity scaling values provided, so there is no concern regarding which scaling values should be used.

In addition, the DICOM standard introduced the concept of [`real world units`](http://dicom.nema.org/dicom/2013/output/chtml/part03/sect_A.46.html). This allows the storage of one or more mappings to allow selective viewing of the data mapped into different value ranges (which may also be non-linear mappings).

Clearly, scaling is a crucial aspect to be aware of for quantitative methods and which representation is used depends upon your needs.
However, the DICOM standard introduced the concept of [`real world units`](http://dicom.nema.org/dicom/2013/output/chtml/part03/sect_A.46.html). This allows the storage of one or more mappings to allow selective viewing of the data mapped into different value ranges (which may also be non-linear mappings).

Philips thinks in terms of three different representations (using the terminology of the documentation available to Philips collaborators):

Expand All @@ -33,16 +31,15 @@ Philips thinks in terms of three different representations (using the terminolog
| Stored Value | SV | Raw data stored in DICOM tag PIXEL DATA tag (7FE0,0010)|
| Displayed Value | DV | The value which is shown to the user when using scanner interface, ROIS, measurements etc. |
| Floating Point | FP | An internal value at a point earlier in the reconstruction chain before the conversion to DICOM/integer for image presentation. |
| Real World Value | WV | DICOM defined real world units|

In general SV should not be used for quantitative measurements as it is an integer format. In practice, if the Rescale values are the same for all images (the typical case, but not guaranteed) SV can be used to compare signal intensities between images from the same scan.

DV can be used for quantitative comparison of signal intensities between images in the same scan as long as the relevant rescale values are taken into account. These rescale values may come from the tags standard tags 0028,1053 and 0028,1052 or from a relevant RealWorld block if present.
In general SV should not be used for quantitative measurements as it is an integer format. In practice, if the Rescale values are the same for all images (the typical case, but not guaranteed) SV can be used to compare signal intensities between images from the same scan. Note that the NIfTI format only provides a single `scl_slope` and `scl_inter` for the entire file, whereas in DICOM rescale values can in theory differ across 2D slices. Therefore, in situations where the rescale values do differ across slices, dcm2niix will apply the requested rescale to each slice and save the scaled data as the 32-bit float NIfTI dataset. This preserves the varibility reported by the rescale tags, at the cost of disk space.

If the DV is derived from a RealWorld block with defined units (tag (0008,0104) such as Hz or ms rather than “no units”) or a RescaleType (0028,1054) with a non-US type (not defined by the standard), then the DV is already quantitative and cross scan comparison may be done.
DV can be used for quantitative comparison of signal intensities between images in the same scan as long as the relevant rescale values are taken into account. These rescale values may come from the tags standard tags 0028,1053 and 0028,1052 or from a relevant RealWorld block if present. If the DV is derived from a RealWorld block with defined units (tag (0008,0104) such as Hz or ms rather than “no units”) or a RescaleType (0028,1054) with a non-US type (not defined by the standard), then the DV is already quantitative and cross scan comparison may be done.

However, in general DV is not sufficient to compare images from different scans, especially if the signal intensity varies a lot (eg multiple inversion recovery scans) in which case the FP value may be used as this may be compared (with some caveats) across scans and across timescales. This scaling requires an additional scale factor on top of the DV value, the Scale Slope (private tag (2005,100E))

dcm2niix copies the raw pixel data from the DICOM tag 7FE0,0010) to NIfTI image. These values are typically stored as 16-bit integers in the range -32768..32767. Both the DICOM and NIfTI formats describe how scaling intercept and slope values can be used to convert these raw values into calibrated values. For example, with an intercept of 0 and slope of 0.01 the raw value of 50 would be converted to 0.5.
As long as rescale values are identical across all DICOM slices, dcm2niix losslessly copies the raw pixel data from the DICOM tag (7FE0,0010) to NIfTI image. These values are typically stored as 16-bit integers in the range -32768..32767. Both the DICOM and NIfTI formats describe how scaling intercept and slope values can be used to convert these raw values into calibrated values. For example, with an intercept of 0 and slope of 0.01 the raw value of 50 would be converted to 0.5.

The [NIfTI](https://nifti.nimh.nih.gov/pub/dist/src/niftilib/nifti1.h) header provides the `scl_slope` and `scl_inter` fields so each voxel value in the dataset is scaled as:

Expand All @@ -52,10 +49,9 @@ I = scl_slope * SV + scl_inter

where `SV` is the raw stored value and `I` is the "true" transformed voxel intensity.

Philips has three possible intensity transforms for their DICOM images (world (`W`), display (`D`), precise (`P`)). All of these transforms might be provided in a single DICOM image, while the [NIfTI](https://nifti.nimh.nih.gov/pub/dist/src/niftilib/nifti1.h) header only designates a single `scl_slope` and `scl_inter` for each image. dcm2niix will retain the stored values (`SV`) and sets the NIfTI `scl_inter` and `scl_slope values` for the desired intensity transform. dcm2niix will use `W` if possible. If this is not possible it will use `P` unless the user specifies `-p n` to disable the precise calculation resulting in `D`.
Philips has three possible intensity transforms for their DICOM images (world (`W`), display (`D`), precise (`P`)). All of these transforms might be provided in a single DICOM image, while the [NIfTI](https://nifti.nimh.nih.gov/pub/dist/src/niftilib/nifti1.h) header only designates a single `scl_slope` and `scl_inter` for each image. dcm2niix will attempt to retain the stored values (`SV`) and sets the NIfTI `scl_inter` and `scl_slope values` for the desired intensity transform. dcm2niix will use `FP` if possible. If this is not possibleor the user specifies `-p n` dcm2niix will use the transforms for `DV`.

The formulas are provided below. The DICOM tags are in brackets (e.g. `(0040,9225)`) and the BIDS tag is in double quotes (e.g. `"PhilipsRWVSlope"`). Since all the scaling values are stored in the BIDS sidecar, you can always use these to generate your preferred intensity transform.

The formulas are provided below. The DICOM tags are in brackets (e.g. `(0040,9225)`) and the BIDS tag is in double quotes (e.g. `"PhilipsRWVSlope"`). Since all the scaling values are stored in the BIDS sidecar, you can always use these to later your preferred intensity transform (assume all slices used the same scaling values).

```
Inputs:
Expand All @@ -66,19 +62,18 @@ Inputs:
RI = rescale intercept (0028,1052) "PhilipsRescaleIntercept"
SS = scale slope (2005,100E) "PhilipsScaleSlope"
Outputs:
W = real world value
P = precise value
D = displayed value
WV = real world value
FP = precise value
DV = displayed value
Formulas:
W = SV * WS + WI
D = SV * RS + RI
P = D / (RS * SS)
WV = SV * WS + WI
DV = SV * RS + RI
FP = DV / (RS * SS)
```


## Derived parametric maps stored with raw diffusion data

Some Philips diffusion DICOM images include derived image(s) along with the images. Other manufacturers save these derived images as a separate series number, and the DICOM standard seems ambiguous on whether it is allowable to mix raw and derived data in the same series (see PS 3.3-2008, C.7.6.1.1.2-3). In practice, many Philips diffusion images append [derived parametric maps](http://www.revisemri.com/blog/2008/diffusion-tensor-imaging/) with the original data. With Philips, appending the derived isotropic image is optional - it is only created for the 'clinical' DTI schemes for radiography analysis and is triggered if the first three vectors in the gradient table are the unit X,Y and Z vectors. For conventional DWI, the result is the conventional mean of the ADC X,Y,Z for DTI it the conventional mean of the 3 principle Eigen vectors. As scientists, we want to discard these derived images, as they will disrupt data processing and we can generate better parametric maps after we have applied undistortion methods such as [Eddy and Topup](https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/eddy/UsersGuide). The current version of dcm2niix uses the Diffusion Directionality (0018,9075) tag to detect B=0 unweighted ("NONE"), B-weighted ("DIRECTIONAL"), and derived ("ISOTROPIC") images. Note that the Dimension Index Values (0020,9157) tag provides an alternative approach to discriminate these images. Here are sample tags from a Philips enhanced image that includes and derived map (3rd dimension is "1" while the other images set this to "2").
Some Philips diffusion DICOM images include derived image(s) along with the images. Other manufacturers save these derived images as a separate series number, and the DICOM standard seems ambiguous on whether it is allowable to mix raw and derived data in the same series (see PS 3.3-2008, C.7.6.1.1.2-3). In practice, many Philips diffusion images append [derived parametric maps](http://www.revisemri.com/blog/2008/diffusion-tensor-imaging/) with the original data. With Philips, appending the derived isotropic image is optional - it is only created for the 'clinical' DTI schemes for radiography analysis and is triggered if the first three vectors in the gradient table are the unit X,Y and Z vectors. For conventional DWI, the result is the conventional mean of the ADC X,Y,Z for DTI it the conventional mean of the 3 principle Eigen vectors. As scientists, we want to discard these derived images, as they will disrupt data processing and we can generate better parametric maps after we have applied undistortion methods such as [Eddy and Topup](https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/eddy/UsersGuide). The current version of dcm2niix uses the Diffusion Directionality (0018,9075) tag to detect B=0 unweighted ("NONE"), B-weighted ("DIRECTIONAL"), and derived ("ISOTROPIC") images. Note that the Dimension Index Values (0020,9157) tag provides an alternative approach to discriminate these images. Here are sample tags from a Philips enhanced image that includes and derived map (3rd dimension is "1" while the other images set this to "2").

```
(0018,9075) CS [DIRECTIONAL]
Expand Down Expand Up @@ -145,7 +140,7 @@ Another value desirable for TOPUP is the "TotalReadoutTime". Again, one can not

## Partial Volumes

NIfTI expects all 3D volumes of a 4D series to have the same number of series (e.g. a time series of 3D fMRI volumes, or a diffusion set with 3D volumes with different gradients applied). If a fMRI sequence is aborted part way through, it is possible that a Philips scanner will only save part of the final volume. An example would be where the total slices (9970) does not equal Dynamics (290) x slices (35) = 10150. Current versions of dcm2niix expect complete volumes. You can repair your data using the console or a Python script, as discussed in [issue 357](https://github.com/rordenlab/dcm2niix/issues/357). To resolve this situation by hand you could also [rename](RENAMING.md) your DICOM files with a call like `./dcm2niix -r y -f %t/%s_%p_%4y_%2r.dcm ~/out 0020,0100`. In this example, the [`%4y`](FILENAMING.md) parameter adds the volume (Temporal Position, 0020,0100) to the filename, allowing you to identify volumes with missing slices.
NIfTI expects all 3D volumes of a 4D series to have the same number of series (e.g. a time series of 3D fMRI volumes, or a diffusion set with 3D volumes with different gradients applied). If a fMRI sequence is aborted part way through, it is possible that a Philips scanner will only save part of the final volume. An example would be where the total slices (9970) does not equal Dynamics (290) x slices (35) = 10150. Current versions of dcm2niix expect complete volumes. You can repair your data using the console or a Python script, as discussed in [issue 357](https://github.com/rordenlab/dcm2niix/issues/357). To resolve this situation by hand you could also [rename](RENAMING.md) your DICOM files with a call like `./dcm2niix -r y -f %t/%s_%p_%4y_%2r.dcm ~/out 0020,0100`. In this example, the [`%4y`](FILENAMING.md) parameter adds the volume (Temporal Position, 0020,0100) to the filename, allowing you to identify volumes with missing slices.

## Non-Image DICOMs

Expand Down
9 changes: 7 additions & 2 deletions console/main_console.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -400,9 +400,14 @@ int main(int argc, const char * argv[])
opts.isForceStackSameSeries = 1;
if ((argv[i][0] == '2'))
opts.isForceStackSameSeries = 2;
if ((argv[i][0] == 'o') || (argv[i][0] == 'O'))
if ((argv[i][0] == 'o') || (argv[i][0] == 'O')) {
opts.isForceStackDCE = false;

//printf("Advanced feature: '-m o' merges images despite varying series number\n");
}
if ((argv[i][0] == '2')) {
opts.isIgnoreSeriesInstanceUID = true;
printf("Advanced feature: '-m 2' ignores Series Instance UID.\n");
}
} else if ((argv[i][1] == 'p') && ((i+1) < argc)) {
i++;
if (invalidParam(i, argv)) return 0;
Expand Down
2 changes: 1 addition & 1 deletion console/nii_dicom.h
Original file line number Diff line number Diff line change
Expand Up @@ -50,7 +50,7 @@ extern "C" {
#define kCPUsuf " " //unknown CPU
#endif

#define kDCMdate "v1.0.20210308"
#define kDCMdate "v1.0.20210317"
#define kDCMvers kDCMdate " " kJP2suf kLSsuf kCCsuf kCPUsuf

static const int kMaxEPI3D = 1024; //maximum number of EPI images in Siemens Mosaic