Original file line number Diff line number Diff line change
Expand Up @@ -10,9 +10,15 @@
<Box File="CVMI_EL2202_E1.xti" Id="2">
<EtherCAT PortABoxInfo="#x01000001"/>
</Box>
<Box File="CVMI_EL6070_E2.xti" Id="3">
<Box File="LED_CH1-2_EL2502.xti" Id="20">
<EtherCAT PortABoxInfo="#x01000002"/>
</Box>
<Box File="LED_CH3-4_EL2502.xti" Id="21">
<EtherCAT PortABoxInfo="#x01000014"/>
</Box>
<Box File="CVMI_EL6070_E2.xti" Id="3">
<EtherCAT PortABoxInfo="#x01000015"/>
</Box>
<Box File="Bridge01_E3.xti" Id="4">
<EtherCAT PortABoxInfo="#x01000003"/>
</Box>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -35,7 +35,7 @@
<Box Id="4" BoxType="9099" BoxFlags="#x00000020">
<Name>__FILENAME__</Name>
<ImageId>1000</ImageId>
<EtherCAT SlaveType="3" AdsServerAddress="ac15845a0205eb03" PdiType="#x0008" MboxDataLinkLayer="true" StateMBoxPolling="true" CycleMBoxPollingTime="0" CoeType="47" EoeType="1" FoeType="1" VendorId="#x00000002" ProductCode="#x1a273052" RevisionNo="#x00050000" InfoDataAddr="true" InfoDataNetId="true" TimeoutMailbox2="2000" GenerateOwnNetId="true" CheckRevisionNoType="3" PortPhys="51" DcTimeLoopControlOnly="true" MaxSlotCount="256" MaxSlotGroupCount="1" SlotPdoIncrement="1" SlotIndexIncrement="16" Type="EL6695 EtherCAT Bridge terminal (Primary)" Desc="EL6695">
<EtherCAT SlaveType="3" AdsServerAddress="ac15845a0205ed03" PdiType="#x0008" MboxDataLinkLayer="true" StateMBoxPolling="true" CycleMBoxPollingTime="0" CoeType="47" EoeType="1" FoeType="1" VendorId="#x00000002" ProductCode="#x1a273052" RevisionNo="#x00050000" InfoDataAddr="true" InfoDataNetId="true" TimeoutMailbox2="2000" GenerateOwnNetId="true" CheckRevisionNoType="3" PortPhys="51" DcTimeLoopControlOnly="true" MaxSlotCount="256" MaxSlotGroupCount="1" SlotPdoIncrement="1" SlotIndexIncrement="16" Type="EL6695 EtherCAT Bridge terminal (Primary)" Desc="EL6695">
<SyncMan>0010000426000100010000008000da050004001026010000</SyncMan>
<SyncMan>0016000422000100020000008000da050004001622010000</SyncMan>
<SyncMan>001c00006400000003000000000000000000001c64010000</SyncMan>
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,75 @@
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<TcSmItem xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://www.beckhoff.com/schemas/2012/07/TcSmItem" TcSmVersion="1.0" TcVersion="3.1.4022.30" ClassName="CFlbTermDef" SubType="9099">
<ImageDatas>
<ImageData Id="1000">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</ImageData>
</ImageDatas>
<Box Id="20" BoxType="9099" BoxFlags="#x00000020">
<Name>__FILENAME__</Name>
<ImageId>1000</ImageId>
<EtherCAT SlaveType="2" PdiType="#x0005" MboxDataLinkLayer="true" StateMBoxPolling="true" CycleMBoxPollingTime="0" CoeType="7" FoeType="1" VendorId="#x00000002" ProductCode="#x09c63052" RevisionNo="#x001a0000" InfoDataAddr="true" TimeoutMailbox2="2000" CheckRevisionNoType="3" PortPhys="51" MaxSlotCount="256" MaxSlotGroupCount="1" SlotPdoIncrement="1" SlotIndexIncrement="16" Type="EL2502 2Ch. PWM output, 24V" Desc="EL2502">
<SyncMan>001080002600010001000000800080008000001026010000</SyncMan>
<SyncMan>801080002200010002000000800080008000801022010000</SyncMan>
<SyncMan>001104002400010003000000000000000400001124010000</SyncMan>
<SyncMan>801100000000000004000000000000000000801100000000</SyncMan>
<Fmmu>0000000000000000001100020100000001000000000000000000000000000000</Fmmu>
<Fmmu>00000000000000000d0800010100000003000000000000000000000000000000</Fmmu>
<BootStrapData>0010f400f410f400</BootStrapData>
<Pdo Name="PWM Outputs Channel 1" Index="#x1600" InOut="1" Flags="#x0010" SyncMan="2">
<ExcludePdo>#x1602</ExcludePdo>
<ExcludePdo>#x1604</ExcludePdo>
<Entry Name="PWM output" Index="#x7000" Sub="#x11">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 2" Index="#x1601" InOut="1" Flags="#x0010" SyncMan="2">
<ExcludePdo>#x1603</ExcludePdo>
<ExcludePdo>#x1605</ExcludePdo>
<Entry Name="PWM output" Index="#x7010" Sub="#x11">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 1" Index="#x1602" InOut="1" Flags="#x0010">
<ExcludePdo>#x1600</ExcludePdo>
<ExcludePdo>#x1604</ExcludePdo>
<Entry Name="PWM output" Index="#x7000" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period" Index="#x7000" Sub="#x12">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 2" Index="#x1603" InOut="1" Flags="#x0010">
<ExcludePdo>#x1601</ExcludePdo>
<ExcludePdo>#x1605</ExcludePdo>
<Entry Name="PWM output" Index="#x7010" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period" Index="#x7010" Sub="#x12">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 1" Index="#x1604" InOut="1" Flags="#x0010">
<ExcludePdo>#x1600</ExcludePdo>
<ExcludePdo>#x1602</ExcludePdo>
<Entry Name="PWM output" Index="#x7000" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period 1Hz" Index="#x7000" Sub="#x13">
<Type>UDINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 2" Index="#x1605" InOut="1" Flags="#x0010">
<ExcludePdo>#x1601</ExcludePdo>
<ExcludePdo>#x1603</ExcludePdo>
<Entry Name="PWM output" Index="#x7010" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period 1Hz" Index="#x7010" Sub="#x13">
<Type>UDINT</Type>
</Entry>
</Pdo>
<CoeProfile ProfileNo="16389001"/>
<CoeProfile ProfileNo="16389001"/>
</EtherCAT>
</Box>
</TcSmItem>
Original file line number Diff line number Diff line change
@@ -0,0 +1,75 @@
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<TcSmItem xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://www.beckhoff.com/schemas/2012/07/TcSmItem" TcSmVersion="1.0" TcVersion="3.1.4022.30" ClassName="CFlbTermDef" SubType="9099">
<ImageDatas>
<ImageData Id="1000">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</ImageData>
</ImageDatas>
<Box Id="21" BoxType="9099" BoxFlags="#x00000020">
<Name>__FILENAME__</Name>
<ImageId>1000</ImageId>
<EtherCAT SlaveType="2" PdiType="#x0005" MboxDataLinkLayer="true" StateMBoxPolling="true" CycleMBoxPollingTime="0" CoeType="7" FoeType="1" VendorId="#x00000002" ProductCode="#x09c63052" RevisionNo="#x001a0000" InfoDataAddr="true" TimeoutMailbox2="2000" CheckRevisionNoType="3" PortPhys="51" MaxSlotCount="256" MaxSlotGroupCount="1" SlotPdoIncrement="1" SlotIndexIncrement="16" Type="EL2502 2Ch. PWM output, 24V" Desc="EL2502">
<SyncMan>001080002600010001000000800080008000001026010000</SyncMan>
<SyncMan>801080002200010002000000800080008000801022010000</SyncMan>
<SyncMan>001104002400010003000000000000000400001124010000</SyncMan>
<SyncMan>801100000000000004000000000000000000801100000000</SyncMan>
<Fmmu>0000000000000000001100020100000001000000000000000000000000000000</Fmmu>
<Fmmu>00000000000000000d0800010100000003000000000000000000000000000000</Fmmu>
<BootStrapData>0010f400f410f400</BootStrapData>
<Pdo Name="PWM Outputs Channel 1" Index="#x1600" InOut="1" Flags="#x0010" SyncMan="2">
<ExcludePdo>#x1602</ExcludePdo>
<ExcludePdo>#x1604</ExcludePdo>
<Entry Name="PWM output" Index="#x7000" Sub="#x11">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 2" Index="#x1601" InOut="1" Flags="#x0010" SyncMan="2">
<ExcludePdo>#x1603</ExcludePdo>
<ExcludePdo>#x1605</ExcludePdo>
<Entry Name="PWM output" Index="#x7010" Sub="#x11">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 1" Index="#x1602" InOut="1" Flags="#x0010">
<ExcludePdo>#x1600</ExcludePdo>
<ExcludePdo>#x1604</ExcludePdo>
<Entry Name="PWM output" Index="#x7000" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period" Index="#x7000" Sub="#x12">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 2" Index="#x1603" InOut="1" Flags="#x0010">
<ExcludePdo>#x1601</ExcludePdo>
<ExcludePdo>#x1605</ExcludePdo>
<Entry Name="PWM output" Index="#x7010" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period" Index="#x7010" Sub="#x12">
<Type>UINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 1" Index="#x1604" InOut="1" Flags="#x0010">
<ExcludePdo>#x1600</ExcludePdo>
<ExcludePdo>#x1602</ExcludePdo>
<Entry Name="PWM output" Index="#x7000" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period 1Hz" Index="#x7000" Sub="#x13">
<Type>UDINT</Type>
</Entry>
</Pdo>
<Pdo Name="PWM Outputs Channel 2" Index="#x1605" InOut="1" Flags="#x0010">
<ExcludePdo>#x1601</ExcludePdo>
<ExcludePdo>#x1603</ExcludePdo>
<Entry Name="PWM output" Index="#x7010" Sub="#x11">
<Type>UINT</Type>
</Entry>
<Entry Name="PWM period 1Hz" Index="#x7010" Sub="#x13">
<Type>UDINT</Type>
</Entry>
</Pdo>
<CoeProfile ProfileNo="16389001"/>
<CoeProfile ProfileNo="16389001"/>
</EtherCAT>
</Box>
</TcSmItem>
Original file line number Diff line number Diff line change
Expand Up @@ -94,7 +94,7 @@
<MBoxUserCmdData>004003000c0000000000000000000000000000000000000000000000000000002081f001040000000000190000</MBoxUserCmdData>
<MBoxUserCmdData>004003000a00000000000000000000000000000000000000000000000000000020f3100502000000010000</MBoxUserCmdData>
<MBoxUserCmdData>020003000c0000000c000000000000000000000000000000000000000000000020111001040000006c6f6164537562496e6465782030303100</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f00000000000000000000000000000000000000000000002010800102000000b80b4d6178696d616c2063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f0000000300000000000000000000000000000000000000201080010200000060094d6178696d616c2063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f000000000000000000000000000000000000000000000020108002020000006400526564756365642063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f0000000000000000000000000000000000000000000000201080030200000080bb4e6f6d696e616c20766f6c7461676500</MBoxUserCmdData>
<MBoxUserCmdData>020003000a00000015000000000000000000000000000000000000000000000020108004020000005f004d6f746f7220636f696c20726573697374616e636500</MBoxUserCmdData>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -94,10 +94,10 @@
<MBoxUserCmdData>004003000c0000000000000000000000000000000000000000000000000000002081f001040000000000190000</MBoxUserCmdData>
<MBoxUserCmdData>004003000a00000000000000000000000000000000000000000000000000000020f3100502000000010000</MBoxUserCmdData>
<MBoxUserCmdData>020003000c0000000c000000000000000000000000000000000000000000000020111001040000006c6f6164537562496e6465782030303100</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f00000000000000000000000000000000000000000000002010800102000000b80b4d6178696d616c2063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f0000000300000000000000000000000000000000000000201080010200000060094d6178696d616c2063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f000000000000000000000000000000000000000000000020108002020000006400526564756365642063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f0000000000000000000000000000000000000000000000201080030200000080bb4e6f6d696e616c20766f6c7461676500</MBoxUserCmdData>
<MBoxUserCmdData>020003000a00000015000000000000000000000000000000000000000000000020108004020000005f004d6f746f7220636f696c20726573697374616e636500</MBoxUserCmdData>
<MBoxUserCmdData>020003000a000000150000000300000000000000000000000000000000000000201080040200000096004d6f746f7220636f696c20726573697374616e636500</MBoxUserCmdData>
<Pdo Name="ENC Status compact" Index="#x1a00" Flags="#x0010" SyncMan="3">
<ExcludePdo>#x1a01</ExcludePdo>
<Entry Name="Status__Latch C valid" Index="#x6000" Sub="#x01">
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -94,7 +94,7 @@
<MBoxUserCmdData>004003000c0000000000000000000000000000000000000000000000000000002081f001040000000000190000</MBoxUserCmdData>
<MBoxUserCmdData>004003000a00000000000000000000000000000000000000000000000000000020f3100502000000010000</MBoxUserCmdData>
<MBoxUserCmdData>020003000c0000000c000000000000000000000000000000000000000000000020111001040000006c6f6164537562496e6465782030303100</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f00000000000000000000000000000000000000000000002010800102000000b80b4d6178696d616c2063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f0000000300000000000000000000000000000000000000201080010200000060094d6178696d616c2063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f000000000000000000000000000000000000000000000020108002020000006400526564756365642063757272656e7400</MBoxUserCmdData>
<MBoxUserCmdData>020003000a0000000f0000000000000000000000000000000000000000000000201080030200000080bb4e6f6d696e616c20766f6c7461676500</MBoxUserCmdData>
<MBoxUserCmdData>020003000a00000015000000000000000000000000000000000000000000000020108004020000005f004d6f746f7220636f696c20726573697374616e636500</MBoxUserCmdData>
Expand Down
3 changes: 1 addition & 2 deletions lcls-plc-cvmi-motion/_Config/NC/Axes/GasJetX.xti
Original file line number Diff line number Diff line change
Expand Up @@ -1356,8 +1356,7 @@ External Setpoint Generation:
</AxisPara>
<Encoder Name="Enc" EncType="4">
<EncPara ScaleFactorNumerator="3.90625e-05" Inverse="true" MaxCount="#x0000ffff">
<SoftEndMinControl Enable="true"/>
<SoftEndMaxControl Enable="true" Range="16.1"/>
<SoftEndMaxControl Range="16.1"/>
<Inc RefSoftSyncMask="#x0000ffff"/>
<ParameterChanged>14</ParameterChanged>
<ParameterChanged>11</ParameterChanged>
Expand Down
7 changes: 3 additions & 4 deletions lcls-plc-cvmi-motion/_Config/NC/Axes/GasJetY.xti
Original file line number Diff line number Diff line change
Expand Up @@ -1356,9 +1356,8 @@ External Setpoint Generation:
<ParameterChanged>257</ParameterChanged>
</AxisPara>
<Encoder Name="Enc" EncType="4">
<EncPara ScaleFactorNumerator="3.90625e-05" MaxCount="#x0000ffff">
<SoftEndMinControl Enable="true"/>
<SoftEndMaxControl Enable="true" Range="99.3"/>
<EncPara ScaleFactorNumerator="9.375e-05" MaxCount="#x0000ffff">
<SoftEndMaxControl Range="99.3"/>
<Inc RefSoftSyncMask="#x0000ffff"/>
<ParameterChanged>11</ParameterChanged>
<ParameterChanged>35</ParameterChanged>
Expand Down Expand Up @@ -1431,7 +1430,7 @@ External Setpoint Generation:
</Encoder>
<Drive Name="Drive" DrvType="24">
<DrvPara>
<Analog VeloReferenz="5" ScaleFactorActTorque="0.1"/>
<Analog VeloReferenz="12" ScaleFactorActTorque="0.1"/>
<TimeComp TaskDelayCycles="1"/>
</DrvPara>
<Vars VarGrpType="1">
Expand Down
3 changes: 1 addition & 2 deletions lcls-plc-cvmi-motion/_Config/NC/Axes/GasJetZ.xti
Original file line number Diff line number Diff line change
Expand Up @@ -1357,8 +1357,7 @@ External Setpoint Generation:
</AxisPara>
<Encoder Name="Enc" EncType="4">
<EncPara ScaleFactorNumerator="9.375e-05" MaxCount="#x0000ffff">
<SoftEndMinControl Enable="true"/>
<SoftEndMaxControl Enable="true" Range="29.4"/>
<SoftEndMaxControl Range="29.4"/>
<Inc RefSoftSyncMask="#x0000ffff"/>
<ParameterChanged>14</ParameterChanged>
<ParameterChanged>11</ParameterChanged>
Expand Down