[kermi] improved README.md, fixed code
Browse files Browse the repository at this point in the history
Signed-off-by: Kai Neuhaus <[email protected]>
  • Loading branch information
KaaNee committed Nov 8, 2024
1 parent 2e53313 commit 831f2e3
Show file tree
Hide file tree
Showing 2 changed files with 13 additions and 6 deletions.
17 changes: 12 additions & 5 deletions bundles/org.openhab.binding.modbus.kermi/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -6,17 +6,20 @@ Kermi X-Center & other attached devices (in progress) are integrated into the Mo
This binding was tested and developed with Kermi x-change dynamic pro heat pump (build 2023).

## Prerequisite

Requirement is contacting Kermi Support to activate Modbus-TCP which can be connected directly by network.
Older devices (non-Pro ?) were connected by Modbus-RCP - maybe you can try to connect them here using a Modbus-TCP modulator (e.x. from waveshare or similar).

## Supported Things

First you need a "Modbus TCP-Bridge" which establishes the basic connection towards your X-Center device.

| Name | Thing Type ID | Description |
|--------------------------|---------------|-----------------------------------------------------------------------------------------------------------------------------|
| Kermi Heat Pump X-Center | kermi-xcenter | Provides (electric) Power values, Flow-information, PV-States, Temperatures and general Information of your Kermi Heat Pump |

## Discovery

This binding does not support autodiscovery.

## Device IDs
Expand All @@ -30,13 +33,15 @@ This binding does not support autodiscovery.

The needed Things can be found in the **Modbus Binding** and have to be added manually without Discovery

1. Create _Modbus TCP Bridge_ with matching Settings of your Kermi Device
1. Create _Modbus TCP Slave (Bridge)_ with matching Settings of your Kermi Device

- IP Address
- Device ID (see [Device IDs](#device-ids))
- Port ID
- **IP Address** - IP Address or hostname of your heatpump
- **Port** - Port of modbus on your heatpump (normally 502)
- **Device ID** - ID on modbus, 40 is default for Kermi (see [Device IDs](#device-ids))

2. Create _Kermi Heat Pump X-Center_ and attach it to the previous installed _Modbus TCP Bridge_. Configuration requires an appropriate Data Refresh Interval with more than 2000 Milliseconds, default is 5000. If it's too fast, you may experience errors in openhab or your x-center ! (Reboot if x-center stops responding on network access). You can enable "PV Modulation" if you want to read the values (default: disabled)
2. Create _Kermi Heat Pump X-Center_ and attach it to the previous installed _Modbus TCP Slave (Bridge)_. Configuration requires an appropriate Data Refresh Interval with more than 2000 Milliseconds, default is 5000. If it's too fast, you may experience errors in openhab or your x-center ! (Reboot if x-center stops responding on network access). You can enable "PV Modulation" if you want to read the values (default: disabled)

Details on Configurations explained below.

### Modbus TCP Slave

Expand Down Expand Up @@ -67,6 +72,8 @@ Select as Bridge a separate (second) Modbus TCP Slave.

## Full Example

Attention: Configuration by file is not recommended. You can configure everything in the main UI.

### kermi.things

```java
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -395,7 +395,7 @@ public void initialize() {
if (bridge.getHandler() instanceof ModbusEndpointThingHandler thingHandler) {
return thingHandler;
} else {
logger.debug("Bridge handler null or unexpected type: {}", handler);
logger.debug("Bridge handler null or unexpected type: {}", bridge.getHandler());
return null;
}
}
Expand Down