Skip to content

Commit

Permalink
Update Rhythm-Plugins.rst
Browse files Browse the repository at this point in the history
- added mention to the OE FPGA Acquisition board plugin, until we unify them.
- removed mention about upcoming support for other Intan hardware - I actually don't know the status of this but it took up space
- added brief comments that sampling rates may differ across devices since the new FPGA has a couple less option in the drop-down menu.
  • Loading branch information
ChucklesOnGitHub authored Nov 27, 2023
1 parent 92e7043 commit 258cf0d
Showing 1 changed file with 3 additions and 3 deletions.
6 changes: 3 additions & 3 deletions source/User-Manual/Plugins/Rhythm-Plugins.rst
Original file line number Diff line number Diff line change
Expand Up @@ -9,7 +9,7 @@ Rhythm Plugins
.. image:: ../../_static/images/plugins/rhythmfpga/rhythmfpga-01.png
:alt: Annotated settings interface for the Acquisition Board plugin

.. csv-table:: Streams data from any device running Intan's "Rhythm" firmware. It is currently compatible with both the `Open Ephys acquisition board <https://open-ephys.org/acq-board>`__ and the `Intan RHD USB Interface Board <https://intantech.com/RHD_USB_interface_board.html>`__. Support for additional Intan hardware is coming soon.
.. csv-table:: Streams data from any device running Intan's "Rhythm" firmware. It is currently compatible with the `Open Ephys acquisition board <https://open-ephys.org/acq-board>`__ and the `Intan RHD USB Interface Board <https://intantech.com/RHD_USB_interface_board.html>`__ by selecting the appropriate processor (Acquisition Board and Intan RHD USB). The Open Ephys FPGA version of the Acquisition Board needs the plugin OE FGPA Acquisition Board which works in the same way.
:widths: 18, 80

"*Plugin Type*", "Source"
Expand All @@ -32,7 +32,7 @@ On the left-hand side of the module, there are slots for each of 8 headstages (A
Sample rate selection
#######################

Sample rates between 1 and 30 kHz can be selected with this drop-down menu. This will determine the sample rate for all headstages, digital inputs, and ADCs.
Sample rates between 1 and 30 kHz can be selected with this drop-down menu. This will determine the sample rate for all headstages, digital inputs, and ADCs. Please note that available sample rates can vary between different hardware.


Bandwidth interface
Expand Down Expand Up @@ -86,4 +86,4 @@ To open the impedance measurement interface, click the "window" or "tab" buttons
.. image:: ../../_static/images/plugins/rhythmfpga/rhythmfpga-02.png
:alt: Annotated impedance measurement interface

|
|