13 changes: 13 additions & 0 deletions data/driver.list.in
Original file line number Diff line number Diff line change
Expand Up @@ -37,6 +37,9 @@
#
# The entry may be followed by comments. Be sure to not use double-quotes there!

"2E" "ups" "2" "PS1000L" "USB" "nutdrv_qx" # https://github.com/networkupstools/nut-ddl/issues/41
"2E" "ups" "2" "PS1000L" "serial" "nutdrv_qx" # https://github.com/networkupstools/nut-ddl/issues/41

"Ablerex" "ups" "2" "625L" "USB" "blazer_usb"
"Ablerex" "ups" "2" "Hope Office 400/600" "" "blazer_ser"
"Ablerex" "ups" "2" "MARS MS3000RT" "" "blazer_ser"
Expand Down Expand Up @@ -71,11 +74,13 @@
"APC" "ups" "1" "Smart-UPS" "" "apcsmart"
"APC" "ups" "1" "Smart-UPS SMT/SMX/SURTD" "Microlink models with RJ45 socket - they *require* AP9620 SmartSlot expansion card and smart cable" "apcsmart"
"APC" "ups" "3" "Back-UPS Pro USB" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS BK650M2-CH" "USB" "usbhid-ups" # https://github.com/networkupstools/nut/issues/1970
"APC" "ups" "3" "Back-UPS (USB)" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS CS USB" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS RS USB" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS LS USB" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS ES/CyberFort 350" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS ES 850G2" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS BF500" "USB" "usbhid-ups"
"APC" "ups" "3" "BACK-UPS XS LCD" "USB" "usbhid-ups"
"APC" "ups" "3" "Back-UPS XS 1000M (Back-UPS Pro 1000, Model BX1000M)" "USB" "usbhid-ups" # https://github.com/networkupstools/nut/issues/139
Expand All @@ -100,6 +105,7 @@
"APC" "ups" "1" "Back-UPS RS 500" "custom non-USB cable" "genericups upstype=20"
"APC" "ups" "3" "Smart-UPS SUA 1000" "" "snmp-ups"
"APC" "ups" "3" "Smart-UPS 3000" "" "snmp-ups"
"APC" "ups" "3" "Smart-UPS 5000 RM (SUA5000RMI5U)" "" "snmp-ups"
"APC" "ups" "3" "Smart-UPS RT XL" "AP9618 SNMP monitoring card" "snmp-ups"
"APC" "ups" "3" "(various)" "AP9618 SNMP monitoring card" "snmp-ups"
"APC" "ups" "3" "(various)" "AP9630 SNMP monitoring card" "snmp-ups privProtocol=AES"
Expand Down Expand Up @@ -658,6 +664,7 @@
"Liebert" "ups" "5" "UPStation GXT2" "contact-closure cable" "liebert"
"Liebert" "ups" "4" "GXE 1-3kVA" "Serial" "liebert-gxe (experimental)"
"Liebert" "ups" "1" "GXT2-3000RT230" "" "liebert-esp2 (experimental)"
"Liebert" "ups" "3" "GXT4-1500RT120" "USB" "usbhid-ups" # https://alioth-lists.debian.net/pipermail/nut-upsdev/2024-September/008013.html
"Liebert" "ups" "3" "PowerSure Personal XT" "USB" "usbhid-ups"
"Liebert" "ups" "3" "PowerSure PSA" "USB" "usbhid-ups"
"Liebert" "ups" "3" "PowerSure PSA 500" "USB" "usbhid-ups"
Expand Down Expand Up @@ -894,6 +901,8 @@
"Mustek" "ups" "2" "Yukai PowerMust" "1000 USB (PID: 5161)" "blazer_usb"
"Mustek" "ups" "2" "Various" "" "blazer_ser"

"NetVision" "ups" "3" "U4BC02CB00NY100" "" "snmp-ups" # https://github.com/networkupstools/nut/issues/1732

"Neus" "ups" "2" "400va / 600va" "" "blazer_ser"

"NHS Sistemas de Energia" "ups" "5" "Expert C Online 6000" "" "gamatronic" # http://www.nhs.com.br/produtos_interna/id/TWpFeQ==
Expand Down Expand Up @@ -1007,6 +1016,8 @@
"PowerMan" "ups" "2" "RealSmart 1000" "" "blazer_ser"
"PowerMan" "ups" "1" "BackPro" "" "genericups upstype=4"

"Powermatic" "ups" "2" "Cleanline L-1000C" "USB" "nutdrv_qx" # https://alioth-lists.debian.net/pipermail/nut-upsdev/2024-September/008015.html

"PowerShield" "ups" "2" "Defender 1200VA" "USB" "blazer_usb"

"PowerTech" "ups" "1" "Comp1000" "DTR cable power" "genericups upstype=3"
Expand Down Expand Up @@ -1208,6 +1219,8 @@

"Sysgration" "ups" "2" "UPGUARDS Pro650" "" "blazer_ser"

"Techly" "ups" "2" "1000VA" "USB" "nutdrv_qx (very little data available with subdriver/protocol=hunnox)" # https://github.com/networkupstools/nut/issues/2651

"Tecnoware" "ups" "2" "Easy Power 1200" "" "blazer_ser"
"Tecnoware" "ups" "2" "UPS ERA LCD 0.65" "USB" "blazer_usb langid_fix=0x409"
"Tecnoware" "ups" "2" "UPS ERA PLUS 1100" "USB" "blazer_usb" # https://www.tecnoware.com/Prodotti/FGCERAPL1100/ups-era-plus-1100.aspx https://github.com/networkupstools/nut/issues/747
Expand Down
9 changes: 8 additions & 1 deletion docs/man/usbhid-ups.txt
Original file line number Diff line number Diff line change
Expand Up @@ -93,7 +93,8 @@ The default value is 20 (in seconds). Usually this *must be lower* than
+
Note that many Cyber Power Systems (CPS) models tend to divide this delay by
60 and round down, so the minimum advisable value is 60 to avoid powering off
immediately after NUT sends the shutdown command to the UPS.
immediately after NUT sends the shutdown command to the UPS. More details
below.

*ondelay*='num'::
Set the timer for the UPS to switch on in case the power returns after the
Expand Down Expand Up @@ -347,6 +348,12 @@ Note that many Cyber Power Systems (CPS) models tend to divide `offdelay`
by 60 and round down, so the minimum advisable value is 60 (seconds) to avoid
powering off immediately after NUT sends the shutdown command to the UPS.

For many Cyberpower UPSs, `offdelay` must be set to `0` for normal behavior
(the load is restored when AC power returns). Setting `offdelay` above `0`
will restart the UPS load *regardless of whether or not power has returned*,
and setting `offdelay` below `0` will disable the auto-power-on function of
the UPS, keeping the load off even when power returns.

UPS does not set battery.charge.low but says OK
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~