62 changes: 62 additions & 0 deletions APC/APC__Smart-UPS_1000__snmp-ups__2.7.4__01.dev
Original file line number Diff line number Diff line change
@@ -0,0 +1,62 @@
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/1740#issuecomment-1364539768

# DEVICE:COMMENT-BLOCK:
# An APC SUA1000 UPS (reports itself as Smart-UPS 1000) connected via SNMPv1
# does not have the problem described in this ticket: Battery Runtime matches
# on UPS and NUT monitoring, and equals `70680.00` here.
# DEVICE:EOC

ambient.1.humidity.alarm.high: 89.00
ambient.1.humidity.alarm.low: 11.00
ambient.1.temperature.alarm.high: 59.00
ambient.1.temperature.alarm.low: 1.00
battery.charge: 93.00
battery.charge.restart: 0
battery.current: 0.00
battery.date: 12/01/22
battery.packs: 4.00
battery.packs.bad: -1.00
battery.runtime: 70680.00
battery.runtime.low: 120
battery.voltage: 25.60
battery.voltage.nominal: -1.00
device.mfr: APC
device.model: Smart-UPS 1000
device.serial: AS0802331853
device.type: ups
driver.name: snmp-ups
driver.parameter.pollfreq: 20
driver.parameter.pollinterval: 2
driver.parameter.port: 192.168.1.51
driver.parameter.snmp_retries: 10
driver.parameter.snmp_timeout: 5
driver.parameter.snmp_version: v1
driver.parameter.synchronous: no
driver.version: 2.7.4
driver.version.data: apcc MIB 1.2
driver.version.internal: 0.97
input.frequency: 50.00
input.sensitivity: medium
input.transfer.high: 253
input.transfer.low: 200
input.transfer.reason: rateOfVoltageChange
input.voltage: 0.00
input.voltage.maximum: 0.00
input.voltage.minimum: 0.00
output.current: 0.40
output.frequency: 50.00
output.voltage: 220.40
output.voltage.nominal: 220
ups.delay.shutdown: 0
ups.delay.start: 0
ups.firmware: 652.18.I
ups.id: kotel
ups.load: 16.90
ups.mfr: APC
ups.mfr.date: 01/12/08
ups.model: Smart-UPS 1000
ups.serial: AS0802331853
ups.status: OB
ups.temperature: 33.30
ups.test.date: 12/11/2022
ups.test.result: Ok
58 changes: 58 additions & 0 deletions APC/APC__Smart-UPS_2200__usbhid-ups__2.7.4__01.dev
Original file line number Diff line number Diff line change
@@ -0,0 +1,58 @@
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/1740#issue-1509493225

# DEVICE:COMMENT-BLOCK:
# The Battery Runtime data does not match the data from the APC UPS.
# This looks like some kind of variable limitation, since the `upsc`
# shows `65535`, which is equal to 18 hours 12 minutes and 15 seconds.
# But in fact, the APC UPS shows the remaining time as 34 hours 1 min.
#
# Packaged "nut is already the newest version (2.7.4-13)".
# DEVICE:EOC

battery.charge: 93
battery.charge.low: 10
battery.charge.warning: 50
battery.mfr.date: 2022/10/25
battery.runtime: 65535
battery.runtime.low: 1200
battery.temperature: 16.6
battery.type: PbAc
battery.voltage: 52.4
battery.voltage.nominal: 48.0
device.mfr: American Power Conversion
device.model: Smart-UPS 2200
device.serial: AS1250244567
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 10
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: no
driver.version: 2.7.4
driver.version.data: APC HID 0.96
driver.version.internal: 0.41
input.sensitivity: medium
input.transfer.high: 253
input.transfer.low: 200
input.voltage: 0.0
output.current: 0.50
output.frequency: 50.0
output.voltage: 220.4
output.voltage.nominal: 220.0
ups.beeper.status: disabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.firmware: 654.19.I
ups.firmware.aux: 7.4
ups.load: 5.2
ups.mfr: American Power Conversion
ups.mfr.date: 2012/12/11
ups.model: Smart-UPS 2200
ups.productid: 0002
ups.serial: AS1250244567
ups.status: OB DISCHRG
ups.test.result: No test initiated
ups.timer.reboot: -1
ups.timer.shutdown: -1
ups.timer.start: -1
ups.vendorid: 051d
48 changes: 48 additions & 0 deletions APC/APC__Smart-UPS_3000__snmp-ups__2.7.4__01.dev
Original file line number Diff line number Diff line change
@@ -0,0 +1,48 @@
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut-ddl/issues/24

ambient.1.humidity.alarm.high: 60.00
ambient.1.humidity.alarm.low: 30.00
ambient.1.temperature.alarm.high: 40.00
ambient.1.temperature.alarm.low: 10.00
battery.charge: 100.00
battery.date: 08/08/2015
battery.runtime: 6900.00
battery.runtime.low: 120
battery.voltage: 54.50
device.mfr: APC
device.model: Smart-UPS 3000
device.serial: AS1532232414
device.type: ups
driver.name: snmp-ups
driver.parameter.pollinterval: 2
driver.parameter.port: ups1.lw
driver.parameter.synchronous: no
driver.version: 2.7.4
driver.version.data: apcc MIB 1.2
driver.version.internal: 0.97
input.frequency: 50.00
input.sensitivity: high
input.transfer.high: 253
input.transfer.low: 207
input.transfer.reason: noTransfer
input.voltage: 228.80
input.voltage.maximum: 228.80
input.voltage.minimum: 226.00
output.current: 0.60
output.frequency: 50.00
output.voltage: 228.80
output.voltage.nominal: 230
ups.delay.shutdown: 120
ups.delay.start: 10
ups.firmware: UPS 09.3 (ID18)
ups.id: APCUPS-1
ups.load: 5.00
ups.mfr: APC
ups.mfr.date: 08/08/2015
ups.model: Smart-UPS 3000
ups.serial: AS1532232414
ups.status: OL
ups.temperature: 23.30
ups.test.date: 03/24/2022
ups.test.result: InvalidTest

46 changes: 46 additions & 0 deletions APC/APC__Smart-UPS_750__usbhid-ups__2.8.0__01.dev
Original file line number Diff line number Diff line change
@@ -0,0 +1,46 @@
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/1261#issuecomment-1702211089

# DEVICE:COMMENT
# Following up from report about Smart-UPS X 750 earlier in the linked ticket
# (about missing data points).
#
# > ...In the meantime I also got a stand alone Smart-UPS 750 (SMT750I).
# > If I'm correct, SMT and SMX series are siblings (released about the
# > same time, share almost identical local LCD interface). SMT are "tower"
# > while SMX are rack mounted and support external battery packs.
# > It reports exactly the same set of data as SMX750I.
# DEVICE:EOC

battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.runtime: 4320
battery.runtime.low: 120
battery.type: PbAc
battery.voltage: 27.1
battery.voltage.nominal: 24.0
device.mfr: American Power Conversion
device.model: Smart-UPS 750
device.serial: AS1316113420
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: auto
driver.version: 2.8.0
driver.version.data: APC HID 0.98
driver.version.internal: 0.47
driver.version.usb: libusb-1.0.26 (API: 0x1000109)
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.firmware: UPS 09.8 / ID=18
ups.mfr: American Power Conversion
ups.mfr.date: 2013/04/19
ups.model: Smart-UPS 750
ups.productid: 0003
ups.serial: AS1316113420
ups.status: OL
ups.timer.reboot: -1
ups.timer.shutdown: -1
ups.vendorid: 051d