Add FSP__Custos9X+_CU-1102TS__nutdrv_qx__2.7.4__01.dev file
- Loading branch information
Showing
1 changed file
with
159 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,159 @@ | ||
# Please add if relevant: DEVICE:URL:REPORT: <GitHub issue/PR or Mailing list archive entry URL> | ||
# Please add if relevant: DEVICE:URL:VENDOR: https://fsp-ps.de/en/product/ups/1489361476-415.html | ||
|
||
# Please add comments for humans here and perhaps raise concerns about the data points, | ||
# see https://networkupstools.org/ddl/#devseq-files for comment-tag syntax | ||
# strip sensitive data (passwords, SNMP community, serial number, IP address, host name...) | ||
# and post as a pull request to https://github.com/networkupstools/nut-ddl/ | ||
# DEVICE:COMMENT: | ||
# Device dump generated by ./nut-ddl-dump.sh on Tue, 12 Sep 2023 15:28:27 +0200 | ||
# DEVICE:EOC | ||
|
||
# :; upsc fsp | ||
battery.charge: 100 | ||
battery.energysave: no | ||
battery.packs: 1 | ||
battery.protection: yes | ||
battery.runtime: 180 | ||
battery.voltage: 54.70 | ||
battery.voltage.nominal: 48.0 | ||
device.model: XIIHVT2K0 | ||
device.serial: 12345678901234 | ||
device.type: ups | ||
driver.name: nutdrv_qx | ||
driver.parameter.bus: 001 | ||
driver.parameter.pollfreq: 30 | ||
driver.parameter.pollinterval: 2 | ||
driver.parameter.port: auto | ||
driver.parameter.productid: 5161 | ||
driver.parameter.synchronous: no | ||
driver.parameter.vendorid: 0665 | ||
driver.version: 2.7.4 | ||
driver.version.data: Voltronic 0.06 | ||
driver.version.internal: 0.28 | ||
input.current.nominal: 8.0 | ||
input.frequency: 50.0 | ||
input.frequency.high: 53.0 | ||
input.frequency.low: 47.0 | ||
input.frequency.nominal: 50.0 | ||
input.phases: 1 | ||
input.transfer.high: 242 | ||
input.transfer.high.max: 254 | ||
input.transfer.high.min: 237 | ||
input.transfer.low: 218 | ||
input.transfer.low.max: 223 | ||
input.transfer.low.min: 206 | ||
input.voltage: 239.4 | ||
input.voltage.nominal: 230.0 | ||
outlet.0.switchable: no | ||
output.current: 0.0 | ||
output.current.nominal: 8 | ||
output.frequency: 0.0 | ||
output.frequency.nominal: 50.0 | ||
output.phases: 1 | ||
output.power.maximum.percent: 1 | ||
output.power.minimum.percent: 1 | ||
output.powerfactor: 0.9 | ||
output.voltage: 0.0 | ||
output.voltage.nominal: 230.0 | ||
ups.beeper.status: enabled | ||
ups.delay.shutdown: 30 | ||
ups.delay.start: 180 | ||
ups.firmware: 01359.08 | ||
ups.firmware.aux: P01 | ||
ups.load: 0 | ||
ups.power.nominal: 2000 | ||
ups.productid: 5161 | ||
ups.start.auto: yes | ||
ups.start.battery: yes | ||
ups.status: OL OFF | ||
ups.temperature: 26.5 | ||
ups.type: online | ||
ups.vendorid: 0665 | ||
|
||
# DEVICE:COMMENT-BLOCK:FIXME:UPSRW: fsp | ||
# [battery.energysave] | ||
# Switch off when running on battery and no/low load | ||
# Type: ENUM | ||
# Option: "no" SELECTED | ||
# Option: "yes" | ||
# | ||
# [battery.packs] | ||
# Number of battery packs | ||
# Type: RANGE | ||
# Option: "1-99" SELECTED | ||
# | ||
# [battery.protection] | ||
# Prevent deep discharge of battery | ||
# Type: ENUM | ||
# Option: "no" | ||
# Option: "yes" SELECTED | ||
# | ||
# [input.frequency.high] | ||
# Maximum input line frequency (Hz) | ||
# Type: RANGE | ||
# Option: "53-60" SELECTED | ||
# | ||
# [input.frequency.low] | ||
# Minimum input line frequency (Hz) | ||
# Type: RANGE | ||
# Option: "40-47" SELECTED | ||
# | ||
# [input.transfer.high] | ||
# High voltage transfer point (V) | ||
# Type: RANGE | ||
# Option: "237-254" SELECTED | ||
# | ||
# [input.transfer.low] | ||
# Low voltage transfer point (V) | ||
# Type: RANGE | ||
# Option: "206-223" SELECTED | ||
# | ||
# [outlet.0.switchable] | ||
# Description unavailable | ||
# Type: ENUM | ||
# Option: "no" SELECTED | ||
# Option: "yes" | ||
# | ||
# [ups.delay.shutdown] | ||
# Interval to wait after shutdown with delay command (seconds) | ||
# Type: RANGE | ||
# Option: "12-5940" SELECTED | ||
# | ||
# [ups.delay.start] | ||
# Interval to wait before (re)starting the load (seconds) | ||
# Type: RANGE | ||
# Option: "0-599940" SELECTED | ||
# | ||
# [ups.start.auto] | ||
# UPS starts when mains is (re)applied | ||
# Type: ENUM | ||
# Option: "no" | ||
# Option: "yes" SELECTED | ||
# | ||
# [ups.start.battery] | ||
# Allow to start UPS from battery | ||
# Type: ENUM | ||
# Option: "no" | ||
# Option: "yes" SELECTED | ||
# DEVICE:EOC | ||
|
||
# DEVICE:COMMENT-BLOCK:FIXME:UPSCMD: fsp | ||
# Instant commands supported on UPS [fsp]: | ||
# | ||
# beeper.disable - Disable the UPS beeper | ||
# beeper.enable - Enable the UPS beeper | ||
# beeper.toggle - Toggle the UPS beeper | ||
# bypass.start - Put the UPS in bypass mode | ||
# bypass.stop - Take the UPS out of bypass mode | ||
# load.off - Turn off the load immediately | ||
# load.on - Turn on the load immediately | ||
# shutdown.return - Turn off the load and return when power is back | ||
# shutdown.stayoff - Turn off the load and remain off | ||
# shutdown.stop - Stop a shutdown in progress | ||
# test.battery.start - Start a battery test | ||
# test.battery.start.deep - Start a deep battery test | ||
# test.battery.start.quick - Start a quick battery test | ||
# test.battery.stop - Stop the battery test | ||
# DEVICE:EOC | ||
|