Skip to content

Commit

Permalink
use multiline regex and match everything at the line start
Browse files Browse the repository at this point in the history
  • Loading branch information
dupondje committed Apr 13, 2023
1 parent 6398c06 commit b933dde
Show file tree
Hide file tree
Showing 2 changed files with 88 additions and 88 deletions.
174 changes: 87 additions & 87 deletions dsmr_parser/obis_references.py
Original file line number Diff line number Diff line change
Expand Up @@ -6,61 +6,61 @@
Might be refactored in a backwards incompatible way as soon as proper telegram
objects are introduced.
"""
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
CURRENT_REACTIVE_IMPORTED = r'\d-\d:3\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TOTAL = r'\d-\d:3\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1 = r'\d-\d:3\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2 = r'\d-\d:3\.8\.2.+?\r\n'
CURRENT_REACTIVE_EXPORTED = r'\d-\d:4\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TOTAL = r'\d-\d:4\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1 = r'\d-\d:4\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2 = r'\d-\d:4\.8\.2.+?\r\n'
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
EQUIPMENT_IDENTIFIER = r'\d-\d:96\.1\.1.+?\r\n'
CURRENT_ELECTRICITY_USAGE = r'\d-\d:1\.7\.0.+?\r\n'
CURRENT_ELECTRICITY_DELIVERY = r'\d-\d:2\.7\.0.+?\r\n'
LONG_POWER_FAILURE_COUNT = r'\d-\d:96\.7\.9.+?\r\n'
SHORT_POWER_FAILURE_COUNT = r'\d-\d:96\.7\.21.+?\r\n'
POWER_EVENT_FAILURE_LOG = r'\d-\d:99\.97\.0.+?\r\n'
VOLTAGE_SAG_L1_COUNT = r'\d-\d:32\.32\.0.+?\r\n'
VOLTAGE_SAG_L2_COUNT = r'\d-\d:52\.32\.0.+?\r\n'
VOLTAGE_SAG_L3_COUNT = r'\d-\d:72\.32\.0.+?\r\n'
VOLTAGE_SWELL_L1_COUNT = r'\d-\d:32\.36\.0.+?\r\n'
VOLTAGE_SWELL_L2_COUNT = r'\d-\d:52\.36\.0.+?\r\n'
VOLTAGE_SWELL_L3_COUNT = r'\d-\d:72\.36\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L1 = r'\d-\d:32\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L2 = r'\d-\d:52\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L3 = r'\d-\d:72\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L1 = r'\d-\d:31\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L2 = r'\d-\d:51\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L3 = r'\d-\d:71\.7\.0.+?\r\n'
TEXT_MESSAGE_CODE = r'\d-\d:96\.13\.1.+?\r\n'
TEXT_MESSAGE = r'\d-\d:96\.13\.0.+?\r\n'
DEVICE_TYPE = r'\d-\d:24\.1\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'\d-\d:21\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'\d-\d:41\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'\d-\d:61\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE = r'\d-\d:23\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE = r'\d-\d:24\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE = r'\d-\d:43\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE = r'\d-\d:44\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE = r'\d-\d:63\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE = r'\d-\d:64\.7\.0.+?\r\n'
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
P1_MESSAGE_HEADER = r'^\d-\d:0\.2\.8.+?\r\n'
P1_MESSAGE_TIMESTAMP = r'^\d-\d:1\.0\.0.+?\r\n'
ELECTRICITY_USED_TARIFF_1 = r'^\d-\d:1\.8\.1.+?\r\n'
ELECTRICITY_USED_TARIFF_2 = r'^\d-\d:1\.8\.2.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_1 = r'^\d-\d:2\.8\.1.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_2 = r'^\d-\d:2\.8\.2.+?\r\n'
CURRENT_REACTIVE_IMPORTED = r'^\d-\d:3\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TOTAL = r'^\d-\d:3\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1 = r'^\d-\d:3\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2 = r'^\d-\d:3\.8\.2.+?\r\n'
CURRENT_REACTIVE_EXPORTED = r'^\d-\d:4\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TOTAL = r'^\d-\d:4\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1 = r'^\d-\d:4\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2 = r'^\d-\d:4\.8\.2.+?\r\n'
ELECTRICITY_ACTIVE_TARIFF = r'^\d-\d:96\.14\.0.+?\r\n'
EQUIPMENT_IDENTIFIER = r'^\d-\d:96\.1\.1.+?\r\n'
CURRENT_ELECTRICITY_USAGE = r'^\d-\d:1\.7\.0.+?\r\n'
CURRENT_ELECTRICITY_DELIVERY = r'^\d-\d:2\.7\.0.+?\r\n'
LONG_POWER_FAILURE_COUNT = r'^\d-\d:96\.7\.9.+?\r\n'
SHORT_POWER_FAILURE_COUNT = r'^\d-\d:96\.7\.21.+?\r\n'
POWER_EVENT_FAILURE_LOG = r'^\d-\d:99\.97\.0.+?\r\n'
VOLTAGE_SAG_L1_COUNT = r'^\d-\d:32\.32\.0.+?\r\n'
VOLTAGE_SAG_L2_COUNT = r'^\d-\d:52\.32\.0.+?\r\n'
VOLTAGE_SAG_L3_COUNT = r'^\d-\d:72\.32\.0.+?\r\n'
VOLTAGE_SWELL_L1_COUNT = r'^\d-\d:32\.36\.0.+?\r\n'
VOLTAGE_SWELL_L2_COUNT = r'^\d-\d:52\.36\.0.+?\r\n'
VOLTAGE_SWELL_L3_COUNT = r'^\d-\d:72\.36\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L1 = r'^\d-\d:32\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L2 = r'^\d-\d:52\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L3 = r'^\d-\d:72\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L1 = r'^\d-\d:31\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L2 = r'^\d-\d:51\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L3 = r'^\d-\d:71\.7\.0.+?\r\n'
TEXT_MESSAGE_CODE = r'^\d-\d:96\.13\.1.+?\r\n'
TEXT_MESSAGE = r'^\d-\d:96\.13\.0.+?\r\n'
DEVICE_TYPE = r'^\d-\d:24\.1\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'^\d-\d:21\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'^\d-\d:41\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'^\d-\d:61\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'^\d-\d:22\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'^\d-\d:42\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'^\d-\d:62\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE = r'^\d-\d:23\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE = r'^\d-\d:24\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE = r'^\d-\d:43\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE = r'^\d-\d:44\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE = r'^\d-\d:63\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE = r'^\d-\d:64\.7\.0.+?\r\n'
EQUIPMENT_IDENTIFIER_GAS = r'^\d-\d:96\.1\.0.+?\r\n'
# TODO differences between gas meter readings in v3 and lower and v4 and up
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
HOURLY_GAS_METER_READING = r'^\d-\d:24\.2\.1.+?\r\n'
GAS_METER_READING = r'^\d-\d:24\.3\.0.+?\r\n.+?\r\n'
ACTUAL_TRESHOLD_ELECTRICITY = r'^\d-\d:17\.0\.0.+?\r\n'
ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n'
VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n'

# TODO 17.0.0
# TODO 96.3.10
Expand All @@ -75,50 +75,50 @@
)

# International generalized additions
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
ELECTRICITY_IMPORTED_TOTAL = r'^\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
ELECTRICITY_EXPORTED_TOTAL = r'^\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)

# International non generalized additions (country specific) / risk for necessary refactoring
BELGIUM_VERSION_INFORMATION = r'\d-\d:96\.1\.4.+?\r\n'
BELGIUM_EQUIPMENT_IDENTIFIER = r'\d-0:96\.1\.1.+?\r\n'
BELGIUM_CURRENT_AVERAGE_DEMAND = r'\d-\d:1\.4\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_MONTH = r'\d-\d:1\.6\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'\d-\d:98\.1\.0.+?\r\n'
BELGIUM_MAX_POWER_PER_PHASE = r'\d-\d:17\.0\.0.+?\r\n' # Applicable when power limitation is active
BELGIUM_MAX_CURRENT_PER_PHASE = r'\d-\d:31\.4\.0.+?\r\n' # Applicable when current limitation is active
BELGIUM_VERSION_INFORMATION = r'^\d-\d:96\.1\.4.+?\r\n'
BELGIUM_EQUIPMENT_IDENTIFIER = r'^\d-0:96\.1\.1.+?\r\n'
BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n'
BELGIUM_MAX_POWER_PER_PHASE = r'^\d-\d:17\.0\.0.+?\r\n' # Applicable when power limitation is active
BELGIUM_MAX_CURRENT_PER_PHASE = r'^\d-\d:31\.4\.0.+?\r\n' # Applicable when current limitation is active

# Multiple 'slaves' can be linked to the main device.
# Mostly MBUS1 = GAS METER with values on 24.2.3
# While WATER METER reports it's values on 24.2.1
# The GAS METER also reports its valve state on 24.4.0
# Dev type for gas = 7 and water = 8
BELGIUM_MBUS1_DEVICE_TYPE = r'\d-1:24\.1\.0.+?\r\n'
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'\d-1:96\.1\.1.+?\r\n'
BELGIUM_MBUS1_VALVE_POSITION = r'\d-1:24\.4\.0.+?\r\n'
BELGIUM_MBUS1_METER_READING1 = r'\d-1:24\.2\.1.+?\r\n'
BELGIUM_MBUS1_METER_READING2 = r'\d-1:24\.2\.3.+?\r\n'
BELGIUM_MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n'
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.1.+?\r\n'
BELGIUM_MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n'
BELGIUM_MBUS1_METER_READING1 = r'^\d-1:24\.2\.1.+?\r\n'
BELGIUM_MBUS1_METER_READING2 = r'^\d-1:24\.2\.3.+?\r\n'

BELGIUM_MBUS2_DEVICE_TYPE = r'\d-2:24\.1\.0.+?\r\n'
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'\d-2:96\.1\.1.+?\r\n'
BELGIUM_MBUS2_VALVE_POSITION = r'\d-2:24\.4\.0.+?\r\n'
BELGIUM_MBUS2_METER_READING1 = r'\d-2:24\.2\.1.+?\r\n'
BELGIUM_MBUS2_METER_READING2 = r'\d-2:24\.2\.3.+?\r\n'
BELGIUM_MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n'
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.1.+?\r\n'
BELGIUM_MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n'
BELGIUM_MBUS2_METER_READING1 = r'^\d-2:24\.2\.1.+?\r\n'
BELGIUM_MBUS2_METER_READING2 = r'^\d-2:24\.2\.3.+?\r\n'

BELGIUM_MBUS3_DEVICE_TYPE = r'\d-3:24\.1\.0.+?\r\n'
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'\d-3:96\.1\.1.+?\r\n'
BELGIUM_MBUS3_VALVE_POSITION = r'\d-3:24\.4\.0.+?\r\n'
BELGIUM_MBUS3_METER_READING1 = r'\d-3:24\.2\.1.+?\r\n'
BELGIUM_MBUS3_METER_READING2 = r'\d-3:24\.2\.3.+?\r\n'
BELGIUM_MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n'
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.1.+?\r\n'
BELGIUM_MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n'
BELGIUM_MBUS3_METER_READING1 = r'^\d-3:24\.2\.1.+?\r\n'
BELGIUM_MBUS3_METER_READING2 = r'^\d-3:24\.2\.3.+?\r\n'

BELGIUM_MBUS4_DEVICE_TYPE = r'\d-4:24\.1\.0.+?\r\n'
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'\d-4:96\.1\.1.+?\r\n'
BELGIUM_MBUS4_VALVE_POSITION = r'\d-4:24\.4\.0.+?\r\n'
BELGIUM_MBUS4_METER_READING1 = r'\d-4:24\.2\.1.+?\r\n'
BELGIUM_MBUS4_METER_READING2 = r'\d-4:24\.2\.3.+?\r\n'
BELGIUM_MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n'
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.1.+?\r\n'
BELGIUM_MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n'
BELGIUM_MBUS4_METER_READING1 = r'^\d-4:24\.2\.1.+?\r\n'
BELGIUM_MBUS4_METER_READING2 = r'^\d-4:24\.2\.3.+?\r\n'


LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'\d-\d:42\.0\.0.+?\r\n' # Logical device name
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name

Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
Q3D_EQUIPMENT_IDENTIFIER = r'^\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'^\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'^\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
2 changes: 1 addition & 1 deletion dsmr_parser/parsers.py
Original file line number Diff line number Diff line change
Expand Up @@ -29,7 +29,7 @@ def __init__(self, telegram_specification, apply_checksum_validation=True):
self.telegram_specification = telegram_specification
# Regexes are compiled once to improve performance
self.telegram_specification_regexes = {
signature: re.compile(signature, re.DOTALL)
signature: re.compile(signature, re.DOTALL | re.MULTILINE)
for signature in self.telegram_specification['objects'].keys()
}

Expand Down

0 comments on commit b933dde

Please sign in to comment.