Laryngeal and Motor Imagery (and SSVEP) with the OpenBCI Cyton+Daisy Mark IV Headset

This repository is code for running an experiment with an OpenBCI 16-channel Mark IV headset. Three BCI control mechanisms are used:

  • SSVEP
  • motor imagery
  • laryngeal imagery

The idea is to test the OpenBCI headset's ability to perform classic control mechanisms (SSVEP and motor imagery), and try a new control paradigm (laryngeal imagery). With laryngeal imagery, the idea is to imagining humming a sound in order to control the BCI. Either different pitches can be used for different control selections, or humming vs no humming can be used.

Conda environment

The conda environment file is contained in openbci.yml. To install the environment, use conda env create -f openbci.yml.

Code files

brainflow_test_wifi.py - can be used to test connection and data collection from OpenBCI headset with a wifi connection brainflow_test_bluetooth.py - can be used to test connection and data collection from OpenBCI headset with a bluetooth connection make_video.py - creates SSVEP videos data_collection.py - code for running the experiment and collection data

Protocol for collecting data

Our sensors were located as follows:

Sensor 10-20 Location
1 FC1
2 FC2
3 C3
4 C4
5 FC5
6 FC6
7 O1
8 O2
9 F7
10 F8
11 F3
12 F4
13 T3
14 T4
15 PO3
16 PO4

A diagram is shown below: sensor diagram

  • First, try to use a freshly-charged battery.
  • Next, put on the headset and use the OpenBCI GUI to ensure the sensors are connected well. This can be done by live streaming the data and checking the impedences for the sensors (clicking on the 'Ohm' buttons for the channels). A reading of less than 500kOhm is sufficient, although lower is better. For higher-quality headsets with wet sensors, 50kOhm is the max recommended. You should be able to clearly see signals in the display.
  • Turn off the impedence measurement, and use the spectrogram to see if alpha waves can be detected. Choose the channels from the occipital lobe (e.g. O3, O4, PO3, PO4) and check that alpha waves appear around 10 Hz when closing your eyes. This should appear as a band of intensity in the spectrogram.
  • An example of alpha waves are shown below: alpha waves
  • Run the experiment data collection file, with python ___ or by first running ipython, then running the file with run ___.

Analyzing data

About

Testing SSVEP with psychopy

Resources