Skip to content

Commit

Permalink
Added documentation for devices
Browse files Browse the repository at this point in the history
### UPDATED
- Added a description for each "do submit handler", "orb security button", "gateway", "security panel" item collections.

### ADDED
- ADT Pulse Gateway (HW 2, with internet unavailable status).
- Collection of orb security buttons when system is unavailable.
  • Loading branch information
mrjackyliang committed Feb 19, 2024
1 parent 95107e7 commit 67d0869
Show file tree
Hide file tree
Showing 4 changed files with 273 additions and 160 deletions.
2 changes: 1 addition & 1 deletion package.json
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
{
"name": "homebridge-adt-pulse",
"displayName": "Homebridge ADT Pulse",
"version": "3.2.1",
"version": "3.2.2",
"description": "Homebridge security system platform for ADT Pulse",
"main": "./build/index.js",
"exports": "./build/index.js",
Expand Down
339 changes: 208 additions & 131 deletions src/lib/items.ts
Original file line number Diff line number Diff line change
Expand Up @@ -36,15 +36,21 @@ import type {
* @since 1.0.0
*/
export const collectionDoSubmitHandlers: CollectionDoSubmitHandlers = [
[],
[
{
href: 'rest/adt/ui/client/security/setForceArm',
},
{
href: 'rest/adt/ui/client/security/setCancelProtest',
},
],
{
description: 'Force arm required',
handlers: [
{
href: 'rest/adt/ui/client/security/setForceArm',
},
{
href: 'rest/adt/ui/client/security/setCancelProtest',
},
],
},
{
description: 'No force arm required',
handlers: [],
},
];

/**
Expand All @@ -53,70 +59,95 @@ export const collectionDoSubmitHandlers: CollectionDoSubmitHandlers = [
* @since 1.0.0
*/
export const collectionOrbSecurityButtons: CollectionOrbSecurityButtons = [
[
{
buttonDisabled: false,
buttonText: 'Arm Away',
loadingText: 'Arming Away',
},
{
buttonDisabled: false,
buttonText: 'Arm Stay',
loadingText: 'Arming Stay',
},
],
[
{
buttonDisabled: false,
buttonText: 'Disarm',
loadingText: 'Disarming',
},
],
[
{
buttonDisabled: true,
buttonText: 'Disarming',
loadingText: null,
},
],
[
{
buttonDisabled: true,
buttonText: 'Arming Away',
loadingText: null,
},
],
[
{
buttonDisabled: true,
buttonText: 'Arming Stay',
loadingText: null,
},
],
[
{
buttonDisabled: true,
buttonText: 'Arming Night',
loadingText: null,
},
],
[
{
buttonDisabled: false,
buttonText: 'Disarm',
loadingText: 'Disarming',
},
{
buttonDisabled: false,
buttonText: 'Arm Away',
loadingText: 'Arming Away',
},
{
buttonDisabled: false,
buttonText: 'Arm Stay',
loadingText: 'Arming Stay',
},
],
{
description: 'System disarmed / Normal',
buttons: [
{
buttonDisabled: false,
buttonText: 'Arm Away',
loadingText: 'Arming Away',
},
{
buttonDisabled: false,
buttonText: 'Arm Stay',
loadingText: 'Arming Stay',
},
],
},
{
description: 'System disarmed / Unresolved sensor problem',
buttons: [
{
buttonDisabled: false,
buttonText: 'Disarm',
loadingText: 'Disarming',
},
{
buttonDisabled: false,
buttonText: 'Arm Away',
loadingText: 'Arming Away',
},
{
buttonDisabled: false,
buttonText: 'Arm Stay',
loadingText: 'Arming Stay',
},
],
},
{
description: 'System armed',
buttons: [
{
buttonDisabled: false,
buttonText: 'Disarm',
loadingText: 'Disarming',
},
],
},
{
description: 'System busy / Disarming',
buttons: [
{
buttonDisabled: true,
buttonText: 'Disarming',
loadingText: null,
},
],
},
{
description: 'System busy / Arming Away',
buttons: [
{
buttonDisabled: true,
buttonText: 'Arming Away',
loadingText: null,
},
],
},
{
description: 'System busy / Arming Stay',
buttons: [
{
buttonDisabled: true,
buttonText: 'Arming Stay',
loadingText: null,
},
],
},
{
description: 'System busy / Arming Night',
buttons: [
{
buttonDisabled: true,
buttonText: 'Arming Night',
loadingText: null,
},
],
},
{
description: 'System unavailable',
buttons: [],
},
];

/**
Expand Down Expand Up @@ -299,54 +330,82 @@ export const collectionSensorActions: CollectionSensorActions = [
*/
export const deviceGateways: DeviceGateways = [
{
broadbandConnectionStatus: 'Active',
cellularConnectionStatus: 'N/A',
cellularSignalStrength: 'N/A',
firmwareVersion: '24.0.0-9',
hardwareVersion: 'HW=1, BL=1.1.9, PL=9.4.0.32.5, SKU=PGZNG1-1ADNAS',
manufacturer: 'ADT Pulse Gateway',
model: 'PGZNG1',
primaryConnectionType: 'Broadband',
description: 'ADT Pulse Gateway PGZNG1 / HW 1 / Broadband Active',
gateway: {
broadbandConnectionStatus: 'Active',
cellularConnectionStatus: 'N/A',
cellularSignalStrength: 'N/A',
firmwareVersion: '24.0.0-9',
hardwareVersion: 'HW=1, BL=1.1.9, PL=9.4.0.32.5, SKU=PGZNG1-1ADNAS',
manufacturer: 'ADT Pulse Gateway',
model: 'PGZNG1',
primaryConnectionType: 'Broadband',
},
},
{
broadbandConnectionStatus: 'Active',
cellularConnectionStatus: 'N/A',
cellularSignalStrength: 'N/A',
firmwareVersion: '24.0.0-9',
hardwareVersion: 'HW=2, BL=1.1.9, PL=9.4.0.32.5, SKU=PGZNG1-1ADNAS',
manufacturer: 'ADT Pulse Gateway',
model: 'PGZNG1',
primaryConnectionType: 'Broadband',
description: 'ADT Pulse Gateway PGZNG1 / HW 2 / Broadband Active',
gateway: {
broadbandConnectionStatus: 'Active',
cellularConnectionStatus: 'N/A',
cellularSignalStrength: 'N/A',
firmwareVersion: '24.0.0-9',
hardwareVersion: 'HW=2, BL=1.1.9, PL=9.4.0.32.5, SKU=PGZNG1-1ADNAS',
manufacturer: 'ADT Pulse Gateway',
model: 'PGZNG1',
primaryConnectionType: 'Broadband',
},
},
{
broadbandConnectionStatus: null,
cellularConnectionStatus: 'Active',
cellularSignalStrength: 'N/A',
firmwareVersion: '27.0.0-140',
hardwareVersion: 'HW=02_CSMAP, BL=NA, PL=27.0.0-140',
manufacturer: null,
model: 'Compact SMA Protocol Gateway',
primaryConnectionType: 'Cellular',
description: 'ADT Pulse Gateway PGZNG1 / HW 2 / Broadband Unavailable',
gateway: {
broadbandConnectionStatus: 'Unavailable',
cellularConnectionStatus: 'N/A',
cellularSignalStrength: 'N/A',
firmwareVersion: '24.0.0-9',
hardwareVersion: 'HW=2, BL=1.1.9, PL=9.4.0.32.5, SKU=PGZNG1-1ADNAS',
manufacturer: 'ADT Pulse Gateway',
model: 'PGZNG1',
primaryConnectionType: 'Broadband',
},
},
{
broadbandConnectionStatus: null,
cellularConnectionStatus: 'Active',
cellularSignalStrength: 'N/A',
firmwareVersion: '27.0.0-140',
hardwareVersion: 'HW=02_Lynx, BL=ICONTROL_CFE 1.0, PL=27.0.0-140',
manufacturer: null,
model: 'Lynx/QuickConnect Cellular-Only Gateway',
primaryConnectionType: 'Cellular',
description: 'ADT TSSC Lifestyle Module / HW 2 / Broadband Active',
gateway: {
broadbandConnectionStatus: 'Active',
cellularConnectionStatus: 'N/A',
cellularSignalStrength: 'N/A',
firmwareVersion: '24.0.0-9',
hardwareVersion: 'HW=0002, BL=UBOOT 2009.08-svn99, PL=5.5.0-5, SKU=TSSC-NA-NONE-01',
manufacturer: 'ADT',
model: 'TSSC Lifestyle Module',
primaryConnectionType: 'Broadband',
},
},
{
broadbandConnectionStatus: 'Active',
cellularConnectionStatus: 'N/A',
cellularSignalStrength: 'N/A',
firmwareVersion: '24.0.0-9',
hardwareVersion: 'HW=0002, BL=UBOOT 2009.08-svn99, PL=5.5.0-5, SKU=TSSC-NA-NONE-01',
manufacturer: 'ADT',
model: 'TSSC Lifestyle Module',
primaryConnectionType: 'Broadband',
description: 'Compact SMA Protocol Gateway / HW 2 / Cellular Active',
gateway: {
broadbandConnectionStatus: null,
cellularConnectionStatus: 'Active',
cellularSignalStrength: 'N/A',
firmwareVersion: '27.0.0-140',
hardwareVersion: 'HW=02_CSMAP, BL=NA, PL=27.0.0-140',
manufacturer: null,
model: 'Compact SMA Protocol Gateway',
primaryConnectionType: 'Cellular',
},
},
{
description: 'Lynx/QuickConnect Cellular-Only Gateway / HW 2 / Cellular Active',
gateway: {
broadbandConnectionStatus: null,
cellularConnectionStatus: 'Active',
cellularSignalStrength: 'N/A',
firmwareVersion: '27.0.0-140',
hardwareVersion: 'HW=02_Lynx, BL=ICONTROL_CFE 1.0, PL=27.0.0-140',
manufacturer: null,
model: 'Lynx/QuickConnect Cellular-Only Gateway',
primaryConnectionType: 'Cellular',
},
},
];

Expand All @@ -357,34 +416,52 @@ export const deviceGateways: DeviceGateways = [
*/
export const deviceSecurityPanels: DeviceSecurityPanels = [
{
emergencyKeys: 'Button: Fire Alarm (Zone 995) Button: Audible Panic Alarm (Zone 999)',
manufacturerProvider: 'ADT',
typeModel: 'TSSC Life Safety Module',
description: 'ADT Safewatch Pro 3000/3000CN - Emergency Keys 95/99',
panel: {
emergencyKeys: 'Button: Fire Alarm (Zone 95) Button: Audible Panic Alarm (Zone 99)',
manufacturerProvider: 'ADT',
typeModel: 'Security Panel - Safewatch Pro 3000/3000CN',
},
},
{
emergencyKeys: 'Button: Fire Alarm (Zone 995) Button: Personal Emergency (Zone 996) Button: Audible Panic Alarm (Zone 999)',
manufacturerProvider: 'ADT',
typeModel: 'TSSC Life Safety Module',
description: 'ADT Safewatch Pro 3000/3000CN - Emergency Keys 95/96/99',
panel: {
emergencyKeys: 'Button: Fire Alarm (Zone 95) Button: Personal Emergency (Zone 96) Button: Audible Panic Alarm (Zone 99)',
manufacturerProvider: 'ADT',
typeModel: 'Security Panel - Safewatch Pro 3000/3000CN',
},
},
{
emergencyKeys: null,
manufacturerProvider: 'DSC',
typeModel: 'Security Panel - Impassa SCW9057',
description: 'ADT TSSC Life Safety Module - Emergency Keys 95/99',
panel: {
emergencyKeys: 'Button: Fire Alarm (Zone 995) Button: Audible Panic Alarm (Zone 999)',
manufacturerProvider: 'ADT',
typeModel: 'TSSC Life Safety Module',
},
},
{
emergencyKeys: 'Button: Fire Alarm (Zone 95) Button: Audible Panic Alarm (Zone 99)',
manufacturerProvider: null,
typeModel: 'Security Panel - LYNX/QuickConnect',
description: 'ADT TSSC Life Safety Module - Emergency Keys 95/96/99',
panel: {
emergencyKeys: 'Button: Fire Alarm (Zone 995) Button: Personal Emergency (Zone 996) Button: Audible Panic Alarm (Zone 999)',
manufacturerProvider: 'ADT',
typeModel: 'TSSC Life Safety Module',
},
},
{
emergencyKeys: 'Button: Fire Alarm (Zone 95) Button: Audible Panic Alarm (Zone 99)',
manufacturerProvider: 'ADT',
typeModel: 'Security Panel - Safewatch Pro 3000/3000CN',
description: 'Ademco LYNX/ADT QuickConnect - Emergency Keys 95/99',
panel: {
emergencyKeys: 'Button: Fire Alarm (Zone 95) Button: Audible Panic Alarm (Zone 99)',
manufacturerProvider: null,
typeModel: 'Security Panel - LYNX/QuickConnect',
},
},
{
emergencyKeys: 'Button: Fire Alarm (Zone 95) Button: Personal Emergency (Zone 96) Button: Audible Panic Alarm (Zone 99)',
manufacturerProvider: 'ADT',
typeModel: 'Security Panel - Safewatch Pro 3000/3000CN',
description: 'DSC Impassa SCW9057',
panel: {
emergencyKeys: null,
manufacturerProvider: 'DSC',
typeModel: 'Security Panel - Impassa SCW9057',
},
},
];