#ts_cRIOcpp

Common functions for C++ development.

OSPL setup

To get history data, and faster/lower bandwidth communication, OSPL shall be run on a machine for multiple users. For that, /tmp/ispddskey_XXXXXX file shall be accessible to users requiring OSPL access. Please see OSPL_SETUP.md for details.

Command hierarchy, Controller processing

Provides abstract Command class. This shall be enqued into ControllerThread internal Command queue. ControllerThread command queue is thread safe (access to it is guarded by mutex and condition_variable). Please see ControllerThread tests for examples.

ILC communication

ILC (Inner-Loop Controller) is a board used on various M1M3 subsystems. ILCs are commanded through serial Modbus connection. The connections are organized on buses, operating on master-worker bus. Either unicasts or broadcasts commands are supported. Broadcasts commands obviously doesn't return anything.

Receiving data from ModBus

After command is send on ModBus, received data are held in a per bus dedicated FIFO. Request code is available to copy content of this FIFO into response FIFO. Synchronization of sending/receiving is done in FPGA class.

Response data are passed to ILC subclass in processResponse call. This method check if responses matches non-broadcast request functions and addresses stored in commanded buffer.

Data are send and received via Common FPGA Modbus module. Please see it for details how Modbus frames are written as UINT 16 values on command FIFO and how data are received from response FIFO.

ILC Modbus Functions

ILC Modbus communication is described in LTS-646. Please see it for detailed description of ILC functions.

ILCs are commanded using custom Modbus functions, which is assigning the following codes (both decimal and hexadecimal code values are shown):

Generic functions

ILCs provides those generic functions:

Code Hex Error Description
17 0x11 145 Report Server ID
18 0x12 146 Report Server Status
65 0x41 193 Change ILC Mode
72 0x48 200 Set Temp ILC Address
107 0x6b 235 Reset Server

Firmware flash functions

Code Hex Description
100 0x64 Write Application Stats - writes CRC etc. after flashing)
101 0x65 Erase ILC application
102 0x66 Write Application Page
103 0x67 Write Verify Application

Pneumatic (FA) ILC functions

Code Hex Description
68 0x44 Freeze Sensor Values
73 0x49 Set Boost Value DCA Gains
74 0x4a Read Boost Value DCA Gains
75 0x4b Force Demand
76 0x4c Force & Status
80 0x50 Set ADC scanrate
110 0x6e Read callibration
119 0x77 Read mezzanine pressure sensors
120 0x78 Report DCA ID
121 0x79 Report DCA Status

Electromechanical (Hardpoint) ILC functions

Code Hex Description
66 0x42 Step motor move
67 0x4c Force & Status
68 0x44 Freeze Sensor Values
80 0x50 Set ADC scanrate
81 0x51 Set ADC Ch Offsets & Sensors
110 0x6e Read callibration

Hardpoint monitoring ILC functions

Code Hex Description
119 0x77 Read mezzanine pressure sensor
120 0x78 Report mezzanine DCP ID
121 0x79 Report mezzanine DCP Status
122 0x7a Read DCP mezzanine board LVDT instruments

Thermal ILC functions

Code Hex Error Description
88 0x58 216 Thermal demand
89 0x59 217 Thermal status

FPGA

Commands are written into 2 bytes (16 bits) commandQueue FIFO in the following format:

Offse Description
0 Command - see FPGA code for details
1 payload length
2-data length payload bytes

Where payload for Modbus uses highest 7 bits for operation code, next 8 bits for data, and last bit as start bit (shall be always 0). See Support System FPGA and Thermal System FPGA for details.