Skip to content

Commit

Permalink
reviewing Spawn documentation (#2487)
Browse files Browse the repository at this point in the history
Co-authored-by: Michael Wetter <[email protected]>
  • Loading branch information
bravache and mwetter authored May 13, 2021
1 parent d61e745 commit 2756426
Showing 1 changed file with 21 additions and 28 deletions.
49 changes: 21 additions & 28 deletions Buildings/ThermalZones/EnergyPlus/UsersGuide.mo
Original file line number Diff line number Diff line change
Expand Up @@ -33,23 +33,20 @@ The <code>.epw</code> file will be used by the EnergyPlus envelope model, and th
file will be used by the Modelica model, and must be specified by the parameter <code>weaName</code>
in the instance <code>building</code>.
</li>
</ol>
The following coupling objects can then be integrated in the model that contains the instance
<code>building</code>, or in any model instantiated by that model
<ul>
<li>
In the model that contains the instance <code>building</code>,
or in any model instantiated by that model, instantiate
for each thermal zone an instance of
<a href=\"modelica://Buildings.ThermalZones.EnergyPlus.ThermalZone\">
Buildings.ThermalZones.EnergyPlus.ThermalZone</a>.
These thermal zones will automatically be assigned the name of the
EnergyPlus input data file and weather file, as well as the other parameters
that are declared in the instance <code>building</code>.
In these instances, specify the name of the thermal zone, as it is entered
in the EnergyPlus input data file, and also assign the medium of the thermal zone,
To connect Modelica zone models with the equivalent EnergyPlus zone envelopes,
instantiate any number of <a href=\"modelica://Buildings.ThermalZones.EnergyPlus.ThermalZone\">
Buildings.ThermalZones.EnergyPlus.ThermalZone</a> models and parameterize them with the name
of the thermal zones as they are entered in the EnergyPlus input data file.
Each model should also be assigned the medium of heat transfer (typically air),
as is done for any other fluid flow component.
This instance will then connect the Modelica zone model with the
EnergyPlus zone model.
</li>
<li>
Optionally, to write to EnergyPlus actuators or schedules during the simulation,
To write to EnergyPlus actuators or schedules during the simulation,
instantiate any number of
<a href=\"modelica://Buildings.ThermalZones.EnergyPlus.Actuator\">
Buildings.ThermalZones.EnergyPlus.Actuator</a>
Expand All @@ -58,26 +55,26 @@ or
Buildings.ThermalZones.EnergyPlus.Schedule</a> models.
</li>
<li>
Optionally, to retrieve the current values of output variables from EnergyPlus,
To retrieve the current values of output variables from EnergyPlus,
instantiate any number of
<a href=\"modelica://Buildings.ThermalZones.EnergyPlus.OutputVariable\">
Buildings.ThermalZones.EnergyPlus.OutputVariable</a> models.
</li>
<li>
Optionally, to model an opaque construction such as a radiant slab in Modelica and interface
To model an opaque construction such as a radiant slab in Modelica and interface
it to EnergyPlus, instantiate any number of
<a href=\"modelica://Buildings.ThermalZones.EnergyPlus.OpaqueConstruction\">
Buildings.ThermalZones.EnergyPlus.OpaqueConstruction</a> models.
</li>
<li>
Optionally, to set individual surface temperatures in EnergyPlus and retrieve their room-side
To set individual surface temperatures in EnergyPlus and retrieve their room-side
heat gains, instantiate any number of
<a href=\"modelica://Buildings.ThermalZones.EnergyPlus.ZoneSurface\">
Buildings.ThermalZones.EnergyPlus.ZoneSurface</a> models.
</li>
</ol>
</ul>
<p>
If you have more than one building, then repeat the above steps for each building and combine
If you have more than one building, you can repeat the above steps for each building and combine
these building models in a top-level model.
See for example
<a href=\"modelica://Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings\">
Expand Down Expand Up @@ -168,8 +165,7 @@ If a zone is in the idf file but not modeled in Modelica, EnergyPlus will
simulate the zone as free floating.
</li>
<li>
If there is an HVAC system in the idf file, then EnergyPlus will remove it.
</li>
All EnergyPlus HVAC objects that are present in the idf file are removed when coupled to Spawn</li>
<li>
For the EnergyPlus envelope, either the CTF transfer function or the finite difference
method can be used.
Expand Down Expand Up @@ -404,15 +400,12 @@ src=\"modelica://Buildings/Resources/Images/ThermalZones/EnergyPlus/envelope-roo
</p>
<p>
The figure above shows an overview of the exchanged coupling variables.
The coupling variables connect Modelica thermal zone model and the EnergyPlus envelope model, or EnergyPlus
surfaces that are connected to heat transfer models
in Modelica, for example to model a radiant floor.
The coupling variables can connect Modelica thermal zone model with EnergyPlus envelope model, or Modelica
heat transfer models to EnergyPlus surfaces, for example to model a radiant floor.
They also allow reading the value of EnergyPlus output variables for use in Modelica-implemented
controllers, and
they allow writing to EnergyPlus schedules and EnergyPlus Energy Management System actuators.
The latter two can be used, for example,
to send supervisory control signals to EnergyPlus, such as for
active facade control, and they also allow the control of lights or equipment schedules that contribute
controllers, and writing to EnergyPlus schedules and EnergyPlus Energy Management System actuators.
This can be used, for instance, to send supervisory control signals to EnergyPlus, such as for
active facade control, or to control lights and equipment schedules that contribute
to heat gains in the room and its surfaces.
</p>
<p>
Expand Down