Merge pull request networkupstools#2133 from jimklimov/upsmon-fsd-noexit
Browse files Browse the repository at this point in the history
clients/upsmon.c et al: introduce SHUTDOWNEXIT boolean option [networkupstools#2133]
  • Loading branch information
jimklimov authored Oct 28, 2023
2 parents 6a08fae + cfc2d72 commit c54c30f
Show file tree
Hide file tree
Showing 5 changed files with 139 additions and 21 deletions.
47 changes: 28 additions & 19 deletions NEWS.adoc
Original file line number Diff line number Diff line change
Expand Up @@ -428,25 +428,34 @@ as part of https://github.com/networkupstools/nut/issues/1410 solution.
- Clarified documentation in codebase according to end-user feedback [#1721,
#1750 and others over time]

- Several fixes for `upsmon` behavior [#1761, #1680...], including new
ability to configure default POWERDOWNFLAG location -- packagers are
encouraged to pick optimal location for their distributions (which
remains mounted at least read-only late in shutdown) and a new optional
POLLFAIL_LOG_THROTTLE_MAX setting [#529, #506]

- Also `upsmon` should now recognize `OFF` and `BYPASS` flags in `ups.status`
and report that these states begin or end. The `OFF` state usually means
than an administrative action happened to power off the load, but the UPS
device is still alive and communicating (USB, SNMP, etc.); corresponding
`MONITOR`'ed amount of power sources are considered not being "fed" for
the power value calculation purposes. The `BYPASS` state is now treated
similarly to `ONBATT`: currently this UPS "feeds" its load, but if later
communications fail, it is considered dead. This may have unintended
consequences for devices (or NUT drivers) that do not report these modes
correctly (e.g. an APC calibration routine seems to start with a few
seconds of "OFF" state), so the reported status is only considered as a
loss of feed if it persists for more than `OFFDURATION` seconds. [#2044,
#2104]
- upsmon client changes include:
* Several fixes for `upsmon` behavior [#1761, #1680...], including new
ability to configure default POWERDOWNFLAG location -- packagers are
encouraged to pick optimal location for their distributions (which
remains mounted at least read-only late in shutdown) and a new optional
POLLFAIL_LOG_THROTTLE_MAX setting [#529, #506]
* Also `upsmon` should now recognize `OFF` and `BYPASS` flags in `ups.status`
and report that these states begin or end. The `OFF` state usually means
than an administrative action happened to power off the load, but the UPS
device is still alive and communicating (USB, SNMP, etc.); corresponding
`MONITOR`'ed amount of power sources are considered not being "fed" for
the power value calculation purposes. The `BYPASS` state is now treated
similarly to `ONBATT`: currently this UPS "feeds" its load, but if later
communications fail, it is considered dead. This may have unintended
consequences for devices (or NUT drivers) that do not report these modes
correctly (e.g. an APC calibration routine seems to start with a few
seconds of "OFF" state), so the reported status is only considered as a
loss of feed if it persists for more than `OFFDURATION` seconds. [#2044,
#2104]
* Introduced `SHUTDOWNEXIT no` configuration toggle for systems which
require a long time to stop their workload such as virtual machines.
Since the disconnection of a "secondary" client is treated by the
"primary" system as permission to proceed with its own shutdown and
power-off for the UPS, the original (now merely default) behavior to
call `SHUTDOWNCMD` and immediately exit could be counter-productive.
An optional delay can also be introduced. [#2133]
* Note there were other changes detailed below which impacted several NUT
programs, including `upsmon`.

- Extended Linux systemd support with optional notifications about daemon
state (READY, RELOADING, STOPPING) and watchdog keep-alive messages [#1590]
Expand Down
45 changes: 45 additions & 0 deletions clients/upsmon.c
Original file line number Diff line number Diff line change
Expand Up @@ -112,6 +112,7 @@ static char *certpasswd = NULL;
static int certverify = 0; /* don't verify by default */
static int forcessl = 0; /* don't require ssl by default */

static int shutdownexitdelay = 0; /* by default doshutdown() exits immediately */
static int userfsd = 0, pipefd[2];
/* Should we run "all in one" (e.g. as root) or split
* into two upsmon processes for some more security? */
Expand Down Expand Up @@ -811,6 +812,28 @@ static void doshutdown(void)
shutdowncmd);
}

if (shutdownexitdelay == 0) {
upsdebugx(1,
"Exiting upsmon immediately "
"after initiating shutdown, by default");
} else
if (shutdownexitdelay < 0) {
upslogx(LOG_WARNING,
"Configured to not exit upsmon "
"after initiating shutdown");
/* Technically, here we sleep until SIGTERM or poweroff */
do {
sleep(1);
} while (!exit_flag);
} else {
upslogx(LOG_WARNING,
"Configured to only exit upsmon %d sec "
"after initiating shutdown", shutdownexitdelay);
do {
sleep(1);
shutdownexitdelay--;
} while (!exit_flag && shutdownexitdelay);
}
exit(EXIT_SUCCESS);
}

Expand Down Expand Up @@ -1581,6 +1604,28 @@ static int parse_conf_arg(size_t numargs, char **arg)
return 1;
}

/* SHUTDOWNEXIT <boolean|number> */
if (!strcmp(arg[0], "SHUTDOWNEXIT")) {
if (!strcasecmp(arg[1], "on")
|| !strcasecmp(arg[1], "yes")
|| !strcasecmp(arg[1], "true")) {
shutdownexitdelay = 0;
} else
if (!strcasecmp(arg[1], "off")
|| !strcasecmp(arg[1], "no")
|| !strcasecmp(arg[1], "false")) {
shutdownexitdelay = -1;
} else {
if (!str_to_int(arg[1], &shutdownexitdelay, 10)) {
upslogx(LOG_WARNING,
"SHUTDOWNEXIT value not recognized, "
"defaulting to 'yes'");
shutdownexitdelay = 0;
}
}
return 1;
}

/* POWERDOWNFLAG <fn> */
if (!strcmp(arg[0], "POWERDOWNFLAG")) {
checkmode(arg[0], powerdownflag, arg[1], reload_flag);
Expand Down
33 changes: 33 additions & 0 deletions conf/upsmon.conf.sample.in
Original file line number Diff line number Diff line change
Expand Up @@ -159,6 +159,39 @@ MINSUPPLIES 1

SHUTDOWNCMD "/sbin/shutdown -h +0"

# --------------------------------------------------------------------------
# SHUTDOWNEXIT <boolean|num>
#
# After initiating shutdown, should this upsmon daemon itself exit?
# By doing so NUT secondary systems can tell the NUT primary that
# it can proceed with its own shutdown and eventually tell the UPS
# to cut power for the load. ("Yes" by default)
#
# Some "secondary" systems with workloads that take considerable time
# to stop (e.g. virtual machines or large databases) can benefit from
# reporting (by virtue of logging off the data server) that they are
# ready for the "primary" system to begin its own shutdown and eventually
# to tell the UPS to cut the power - not as soon as they have triggered
# their own shutdown, but at a later point (e.g. when the upsmon service
# is stopped AFTER the heavier workloads).
#
# Note that the actual ability to complete such shutdown depends on the
# remaining battery run-time at the moment when UPS power state becomes
# considered critical and the shutdowns begin. You may also have to tune
# HOSTSYNC on the NUT primary to be long enough for those secondaries to
# stop their services. In practice, it may be worthwhile to investigate
# ways to trigger shutdowns earlier on these systems, e.g. by setting up
# `upssched` integration, or `dummy-ups` driver with overrides for stricter
# `battery.charge` or `battery.runtime` triggers than used by the rest of
# your servers.
#
# This option supports Boolean-style strings (yes/on/true or no/off/false)
# or numbers to define a delay (in seconds) between calling SHUTDOWNCMD
# and exiting the daemon. Zero means immediate exit (default), negative
# values mean never exiting on its own accord.
#
#SHUTDOWNEXIT yes

# --------------------------------------------------------------------------
# NOTIFYCMD <command>
#
Expand Down
30 changes: 30 additions & 0 deletions docs/man/upsmon.conf.txt
Original file line number Diff line number Diff line change
Expand Up @@ -384,6 +384,36 @@ together, i.e.:

SHUTDOWNCMD "/sbin/shutdown -h +0"

*SHUTDOWNEXIT* 'boolean|number'::

After initiating shutdown, should this upsmon daemon itself exit?
By doing so NUT secondary systems can tell the NUT primary that
it can proceed with its own shutdown and eventually tell the UPS
to cut power for the load. ("Yes" by default)
+
Some "secondary" systems with workloads that take considerable time
to stop (e.g. virtual machines or large databases) can benefit from
reporting (by virtue of logging off the data server) that they are
ready for the "primary" system to begin its own shutdown and eventually
to tell the UPS to cut the power - not as soon as they have triggered
their own shutdown, but at a later point (e.g. when the upsmon service
is stopped AFTER the heavier workloads).
+
Note that the actual ability to complete such shutdown depends on the
remaining battery run-time at the moment when UPS power state becomes
considered critical and the shutdowns begin. You may also have to tune
`HOSTSYNC` on the NUT primary to be long enough for those secondaries to
stop their services. In practice, it may be worthwhile to investigate
ways to trigger shutdowns earlier on these systems, e.g. by setting up
`upssched` integration, or `dummy-ups` driver with overrides for stricter
`battery.charge` or `battery.runtime` triggers than used by the rest of
your servers.
+
This option supports Boolean-style strings (yes/on/true or no/off/false)
or numbers to define a delay (in seconds) between calling `SHUTDOWNCMD`
and exiting the daemon. Zero means immediate exit (default), negative
values mean never exiting on its own accord.

*CERTPATH* 'certificate file or database'::

When compiled with SSL support, you can enter the certificate path here.
Expand Down
5 changes: 3 additions & 2 deletions docs/nut.dict
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
personal_ws-1.1 en 3255 utf-8
personal_ws-1.1 en 3257 utf-8
AAC
AAS
ABI
Expand Down Expand Up @@ -1111,6 +1111,7 @@ SG
SGI
SHA
SHUTDOWNCMD
SHUTDOWNEXIT
SIG
SIGHUP
SIGINT
Expand Down Expand Up @@ -1324,7 +1325,6 @@ UPS's
UPSCONN
UPSDESC
UPSHOST
upsid
UPSIMAGEPATH
UPSLC
UPSOutletSystemOutletDelayBeforeReboot
Expand Down Expand Up @@ -3096,6 +3096,7 @@ upsfetch
upsgone
upsh
upshandler
upsid
upsidentmodel
upsimage
upsload
Expand Down

0 comments on commit c54c30f

Please sign in to comment.