Notifications
You must be signed in to change notification settings - Fork 20
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
[uss_qualifier/scenarios/netrid] Factor away test step fragments from…
… scenario
- Loading branch information
Showing
12 changed files
with
341 additions
and
291 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
7 changes: 7 additions & 0 deletions
7
...ss_qualifier/scenarios/astm/netrid/v19/common_dictionary_evaluator_dp_flight.md
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,7 @@ | ||
# ASTM NetRID v19 Display Provider flight consistency with Common Data Dictionary test step fragment | ||
|
||
This fragment is implemented in `common_dictionary_evaluator.py:RIDCommonDictionaryEvaluator.evaluate_dp_flight`. | ||
|
||
#### Correct up-to-date altitude if present check | ||
|
||
If the observed altitude of a flight is reported, but it does not match the altitude of the injected telemetry, the display provider is not providing precise and up-to-date information, and thus does not respect **[astm.f3411.v19.NET0450](../../../../requirements/astm/f3411/v19.md)**. |
43 changes: 43 additions & 0 deletions
43
...ss_qualifier/scenarios/astm/netrid/v19/common_dictionary_evaluator_sp_flight.md
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,43 @@ | ||
# ASTM NetRID v19 Service Provider flight consistency with Common Data Dictionary test step fragment | ||
|
||
This fragment is implemented in `common_dictionary_evaluator.py:RIDCommonDictionaryEvaluator.evaluate_sp_flights`. | ||
|
||
## Service Provider altitude check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,11](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. Injected flight data had known altitudes, but the altitude reported by the Service Provider did not match those known altitudes. | ||
|
||
## ⚠️ Service Provider vertical speed check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,20](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. Injected flight data had a specified vertical speed that was different from the reported one. | ||
|
||
## ⚠️ Service Provider speed check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,19](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. Injected flight data had a specified speed that was different from the reported one. | ||
|
||
## ⚠️ Service Provider speed accuracy check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,17](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. Injected flight data had a specified speed accuracy that was different from the reported one. | ||
|
||
## ⚠️ Service Provider track check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,18](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. Injected flight data had a specified track that was different from the reported one. | ||
|
||
## ⚠️ Service Provider geodetic altitude accuracy check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,15](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. Injected flight data had a specified geodetic altitude accuracy that was different from the reported one. | ||
|
||
## ⚠️ Service Provider horizontal accuracy check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,16](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. Injected flight data had a specified horizontal accuracy that was different from the reported one. | ||
|
||
## ⚠️ Service Provider timestamp accuracy is present check | ||
|
||
If the timestamp accuracy is not present, the USS under test is not properly implementing the REST interface specified by the OpenAPI definition contained in Annex A4, and is therefore in violation of **[astm.f3411.v19.NET0710,1](../../../../requirements/astm/f3411/v19.md)**. | ||
|
||
## ⚠️ Service Provider timestamp accuracy is correct check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,5](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. The observed timestamp accuracy differs from the injected one. | ||
|
||
## ⚠️ Service Provider height check | ||
|
||
**[astm.f3411.v19.NET0260,Table1,13](../../../../requirements/astm/f3411/v19.md)** requires that relevant Remote ID data, consistent with the common data dictionary, be reported by the Service Provider. The reported height of the flight is unrealistic or otherwise not consistent with the injected data. |
29 changes: 29 additions & 0 deletions
29
...ng/uss_qualifier/scenarios/astm/netrid/v19/display_data_evaluator_clustering.md
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,29 @@ | ||
# ASTM NetRID v19 clustering test step fragment | ||
|
||
This fragment is implemented in `display_data_evaluator.py:RIDObservationEvaluator._evaluate_clusters_observation`. | ||
|
||
#### Minimal obfuscation distance of individual flights check | ||
|
||
For a display area with a diagonal greater than *NetDetailsMaxDisplayAreaDiagonal* and less than *NetMaxDisplayAreaDiagonal*, **[astm.f3411.v19.NET0490](../../../../requirements/astm/f3411/v19.md)** requires that a Display provider shall obfuscate individual UAs within a cluster. | ||
If a cluster with a single flight has a width or height smaller than 2 * *NetMinObfuscationDistance* (meaning that the USS did not buffer the single point by *NetMinObfuscationDistance* in all directions when forming the cluster bounds), this test will fail. | ||
|
||
#### Individual flights obfuscation check | ||
|
||
For a display area with a diagonal greater than *NetDetailsMaxDisplayAreaDiagonal* and less than *NetMaxDisplayAreaDiagonal*, **[astm.f3411.v19.NET0490](../../../../requirements/astm/f3411/v19.md)** requires that a Display provider shall obfuscate individual UAs within a cluster. | ||
If a cluster with a single flight has its center equal to the position of the flight, this test will fail. | ||
If a cluster with a single flight does not actually encompass the flight, this test will fail. | ||
|
||
#### Minimal obfuscation distance of multiple flights clusters check | ||
|
||
For a display area with a diagonal greater than *NetDetailsMaxDisplayAreaDiagonal* and less than *NetMaxDisplayAreaDiagonal*, **[astm.f3411.v19.NET0480](../../../../requirements/astm/f3411/v19.md)** requires that a Display provider shall cluster UAs in close proximity to each other using a circular or polygonal area. | ||
If a cluster with multiples flights has a width or height smaller than 2 * *NetMinObfuscationDistance*, this test will fail. A larger width or height might still be incorrect, but the test cannot at the moment determine this. | ||
|
||
#### Clustering count check | ||
|
||
For a display area with a diagonal greater than *NetDetailsMaxDisplayAreaDiagonal* and less than *NetMaxDisplayAreaDiagonal*, **[astm.f3411.v19.NET0480](../../../../requirements/astm/f3411/v19.md)** requires that a Display provider shall cluster UAs in close proximity to each other using a circular or polygonal area. | ||
Taking into account the propagation time of the injected flights, if the total number of clustered UAs when this value is expected to be stable is not correct, this test will fail. | ||
|
||
#### Minimal display area of clusters check | ||
|
||
For a display area with a diagonal greather than *NetDetailsMaxDisplayAreaDiagonal* and less than *NetMaxDisplayAreaDiagonal*, **[astm.f3411.v19.NET0480](../../../../requirements/astm/f3411/v19.md)** requires that a Display provider shall cluster UAs in close proximity to each other using a circular or polygonal area covering no less than *NetMinClusterSize* percent of the display area size. | ||
This check validates that the display area of a cluster, measured and provided in square meters by the test harness, is no less than *NetMinClusterSize* percent of the display area. |
Oops, something went wrong.