Add data with currently working reference link, fix minor bad assignm…
Browse files Browse the repository at this point in the history
…ents
  • Loading branch information
fabian.wuellhorst committed Nov 10, 2023
1 parent 003e251 commit f7dba66
Show file tree
Hide file tree
Showing 10 changed files with 115 additions and 66 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -12,8 +12,8 @@ record Carrier30XWP1012_1MW
291.15,161024,183752,210396,240550,274249],
mCon_flow_nominal=49.85,
mEva_flow_nominal=49.85,
dpCon_nominal=32000,
dpEva_nominal=44000,
dpCon_nominal=32000,
dpEva_nominal=44000,
tabLowBou=[293.15,276.15; 323.15,276.15],
devIde="Carrier30XWP1012",
use_TConOutForOpeEnv=true,
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -31,6 +31,10 @@ record Vitocal251A08 "A2W Vitocal 251 by Viessmann"
The pressure loss depends mostly on the hydraulic system
according to the datasheet.
</p>
<p>
The nominal mass flow rate is calculated for the nominal point A7/W35,
with a temperature spread of 5 K.
</p>
<h4>References</h4>
<p>
Viessmann, Planungshandbuch.
Expand Down
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
BoundaryMap
CycleRateBoundary
OnPastThreshold
PartialOperationalEnvelope
PartialSafety
PartialSafetyWithCounter
PartialOperationalEnvelope
Original file line number Diff line number Diff line change
Expand Up @@ -6,14 +6,14 @@ record SingleSplitRXM20R "Daikin_FTXM20R_RXM20R heating mode"
use_TEvaOutForOpeEnv=false,
dpEva_nominal=0,
dpCon_nominal=0,
tabPEle=[0,258.15, 263.15, 268.15, 273.15, 280.15, 283.15;
tabQCon_flow=[0,258.15, 263.15, 268.15, 273.15, 280.15, 283.15;
288.15,1190,1430,1670,1940,2590,2810;
293.15,1120,1360,1600, 1860,2500,2730;
295.15,1090,1330,1570,1830,2470,2690;
297.15,1060,1300,1540,1800,2430,2660;
298.15,1040,1280,1520,1780,2410,2640;
300.15,1010,1250,1490,1760,2380,2610],
tabQCon_flow=[0,258.15, 263.15, 268.15, 273.15, 280.15, 283.15;
tabPEle=[0,258.15, 263.15, 268.15, 273.15, 280.15, 283.15;
288.15,320,340,360,460,490,510;
293.15,330,350,370,470,500,520;
295.15,340,360,370,480,500,520;
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -37,6 +37,10 @@ record Vitocal251A08 "A2W Vitocal 251 by Viessmann"
The pressure loss depends mostly on the hydraulic system
according to the datasheet.
</p>
<p>
The nominal mass flow rate is calculated for the nominal point A7/W35,
with a temperature spread of 5 K.
</p>
<h4>References</h4>
<p>
Viessmann, Planungshandbuch.
Expand Down

This file was deleted.

Original file line number Diff line number Diff line change
@@ -0,0 +1,90 @@
within IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511;
record WAMAK_WaterToWater_220kW "220 kW water to water with R513A"
extends
IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericHeatPump(
dpEva_nominal(displayUnit="kPa") = 40000,
dpCon_nominal(displayUnit="kPa") = 40000,
tabUppBou=[
268.15, 328.15;
273.15, 333.15;
283.15, 343.15;
293.15, 353.15],
mEva_flow_nominal=27.35/3600*997,
mCon_flow_nominal=29.07/3600*997,
tabPEle=[0, 268.15, 269.15, 270.15, 271.15, 272.15, 273.15, 274.15, 275.15,
276.15, 277.15, 278.15, 279.15, 280.15, 281.15, 282.15, 283.15, 284.15,
285.15, 286.15, 287.15, 288.15, 289.15, 290.15, 291.15, 292.15, 293.15,
294.15, 295.15, 296.15, 297.15, 298.15, 299.15, 300.15, 301.15, 302.15,
303.15, 304.15, 305.15, 306.15, 307.15, 308.15, 309.15, 310.15, 311.15,
312.15, 313.15, 314.15, 315.15, 316.15, 317.15, 318.15;
328.15, 30100, 30100, 30100, 30100, 30100, 30100, 30100, 30100, 30100,
30100, 30200, 30200, 30200, 30200, 30200, 30300, 30300, 30300, 30400,
30400, 30400, 30500, 30500, 30600, 30600, 30700, 30700, 30800, 30800,
30900, 31000, 31000, 31100, 31200, 31200, 31300, 31400, 31500, 31500,
31600, 31700, 31800, 31900, 32000, 32100, 32200, 32300, 32400, 32500,
32600, 32700;
333.15, 0, 0, 0, 0, 0, 33500, 33500, 33500, 33500, 33500, 33500, 33500,
33600, 33600, 33600, 33600, 33600, 33600, 33600, 33700, 33700, 33700,
33700, 33800, 33800, 33900, 33900, 33900, 34000, 34000, 34100, 34100,
34200, 34200, 34300, 34300, 34400, 34400, 34500, 34600, 34600, 34700,
34800, 34900, 34900, 35000, 35100, 35200, 35300, 35400, 35400;
343.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 41700, 41600, 41600,
41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600,
41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41700, 41700,
41700, 41700, 41700, 41800, 41800, 41800, 41900, 41900, 41900, 42000,
42000, 42100, 42100;
353.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0, 0, 51400, 51400, 51300, 51300, 51200, 51200, 51200, 51100,
51100, 51000, 51000, 51000, 50900, 50900, 50900, 50800, 50800, 50800,
50800, 50700, 50700, 50700, 50700, 50600, 50600, 50600],
tabQCon_flow=[0, 268.15, 269.15, 270.15, 271.15, 272.15, 273.15, 274.15,
275.15, 276.15, 277.15, 278.15, 279.15, 280.15, 281.15, 282.15, 283.15,
284.15, 285.15, 286.15, 287.15, 288.15, 289.15, 290.15, 291.15, 292.15,
293.15, 294.15, 295.15, 296.15, 297.15, 298.15, 299.15, 300.15, 301.15,
302.15, 303.15, 304.15, 305.15, 306.15, 307.15, 308.15, 309.15, 310.15,
311.15, 312.15, 313.15, 314.15, 315.15, 316.15, 317.15, 318.15;
328.15, 65800, 68000, 70200, 72400, 74800, 77200, 79700, 82300, 84900,
87700, 90500, 93400, 96400, 99500, 102600, 105900, 109300, 112800,
116400, 120100, 123900, 127800, 131900, 136100, 140400, 144800, 149300,
154000, 158800, 163800, 168900, 174100, 179500, 185000, 190700, 196600,
202600, 208700, 215000, 221500, 228200, 235000, 242000, 249200, 256500,
264100, 271800, 279700, 287800, 296100, 304600;
333.15, 0, 0, 0, 0, 0, 75200, 77600, 80000, 82500, 85000, 87700, 90400,
93200, 96100, 99100, 102100, 105300, 108600, 111900, 115400, 119000,
122600, 126400, 130300, 134400, 138500, 142800, 147200, 151700, 156300,
161100, 166100, 171100, 176300, 181700, 187200, 192800, 198600, 204600,
210700, 217000, 223400, 230000, 236800, 243800, 250900, 258200, 265700,
273400, 281200, 289300;
343.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 95000, 97700, 100500,
103300, 106300, 109400, 112500, 115800, 119100, 122600, 126100, 129800,
133600, 137500, 141500, 145600, 149900, 154300, 158800, 163500, 168200,
173200, 178200, 183400, 188800, 194300, 199900, 205700, 211700, 217800,
224100, 230600, 237200, 244000, 250900, 258100;
353.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0, 114300, 117300, 120500, 123700, 127000, 130500, 134100, 137700,
141500, 145400, 149500, 153600, 157900, 162300, 166800, 171500, 176300,
181300, 186400, 191700, 197100, 202600, 208300, 214200, 220200, 226400],
devIde="WAMAK_TWW220_WHR_HeavyDuty",
use_TConOutForTab=true,
use_TEvaOutForTab=false);
annotation (Documentation(info="<html>
<p>
Data for large scale (220 kW) water-to-water heat pump from WAMAK.
Nominal pressure losses are the maximal values given in the datasheet,
same for the nominal mass flow rates.
</p>
<h4>References</h4>
<p>
WAMAK, Produktblatt ver. 2023/24.
<a href=\"https://products.wamak.eu/combine.php?&coverpg&descriptmrktadv&lang=de-DE&code_id=WAHDR2XE\">
https://products.wamak.eu/combine.php?&coverpg&descriptmrktadv&lang=de-DE&code_id=WAHDR2XE</a>.
</p>
</html>", revisions="<html>
<ul><li>
<i>November 10, 2023</i> by Fabian Wuellhorst:<br/>
First implementation (see issue <a href=
\"https://github.com/ibpsa/modelica-ibpsa/issues/1576\">#1576</a>)
</li></ul>
</html>"));
end WAMAK_WaterToWater_220kW;
Original file line number Diff line number Diff line change
@@ -1,3 +1,3 @@
SingleSplitRXM20R
Vitocal251A08
WAMAK_WaterToWater_150kW
WAMAK_WaterToWater_220kW
Original file line number Diff line number Diff line change
Expand Up @@ -10,22 +10,28 @@ model LargeScaleWaterToWater_OneRoomRadiator
Q_flow_nominal=200000,
sin(nPorts=1),
booToReaPumEva(realTrue=heaPum.mEva_flow_nominal),
oneRooRadHeaPumCtr(PIDHea(Ti=10)));
oneRooRadHeaPumCtr(PIDHea(Ti=10)),
pumHeaPum(redeclare
IBPSA.Fluid.Movers.Data.Pumps.Wilo.VeroLine80slash115dash2comma2slash2
per),
pumHeaPumSou(redeclare
IBPSA.Fluid.Movers.Data.Pumps.Wilo.VeroLine80slash115dash2comma2slash2
per));
extends Modelica.Icons.Example;

IBPSA.Fluid.HeatPumps.ModularReversible.LargeScaleWaterToWater heaPum(
QUse_flow_nominal=Q_flow_nominal,
y_nominal=1,
use_intSafCtr=true,
TCon_nominal=TRadSup_nominal,
dpCon_nominal(displayUnit="Pa") = 2000,
dpCon_nominal(displayUnit="Pa"),
TEva_nominal=sou.T,
dpEva_nominal(displayUnit="Pa") = 2000,
dpEva_nominal(displayUnit="Pa"),
energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial,
redeclare IBPSA.Fluid.HeatPumps.ModularReversible.Controls.Safety.Data.Wuellhorst2021
safCtrParEurNor,
redeclare
IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.WAMAK_WaterToWater_150kW
IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.WAMAK_WaterToWater_220kW
datTab)
"Large scale water to water heat pump"
annotation (Placement(transformation(extent={{20,-160},{0,-136}})));
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -42,8 +42,7 @@ model LargeScaleWaterToWater
final autCalVEva=max(1E-7*QUse_flow_nominal - 75E-4, autCalVMin));

replaceable parameter
IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericHeatPump datTab=
IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.WAMAK_WaterToWater_150kW()
IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericHeatPump datTab
"Data Table of HP" annotation (choicesAllMatching=true);
replaceable parameter
IBPSA.Fluid.HeatPumps.ModularReversible.Controls.Safety.Data.Wuellhorst2021
Expand Down

0 comments on commit f7dba66

Please sign in to comment.