Improved documentation of MultiWell
Browse files Browse the repository at this point in the history
  • Loading branch information
Alessandro Maccarini committed Sep 15, 2023
1 parent e949283 commit ac8bbdc
Showing 1 changed file with 11 additions and 8 deletions.
19 changes: 11 additions & 8 deletions IBPSA/Fluid/Geothermal/Aquifer/MultiWell.mo
Original file line number Diff line number Diff line change
Expand Up @@ -414,6 +414,15 @@ is the temperature at location <i>r</i> and time <i>t</i>,
The first term on the right hand side of the equation describes the effect of conduction, while
the second term describes the fluid flow.
</p>
<p>
The pressure losses in the aquifer are calculated using the Darcy's law
<p align=\"center\" style=\"font-style:italic;\">
&#916;p = &#7745; g &frasl; (2 &#960; K h ln(rMax &frasl; rWB))
</p>
where <i>&#7745;</i> is the water mass flow rate, <i>g</i> is the gravitational acceleration, <i>K</i> is the hydraulic conductivity, <i>h</i> is the thickness of the aquifer,
<i>rMax</i> is the domain radius and <i>rWB</i> is the well radius. The pressure losses in the wells are calculated using
<a href=\"modelica://Modelica.Fluid.Pipes.BaseClasses.WallFriction.Detailed.pressureLoss_m_flow\">Modelica.Fluid.Pipes.BaseClasses.WallFriction.Detailed.pressureLoss_m_flow</a>.
</p>
<h4>Spatial discretization</h4>
<p>
To discretize the conductive-convective equation, the domain is divided into a series
Expand All @@ -431,11 +440,11 @@ The geometric representation of the model is illustrated in the figure below.
</p>
<h4>Typical use and important parameters</h4>
<p>
By default, the component consists of a cold well and a warm well. The number of wells can be increased by modifing the parameters <code>nCoo</code> and <code>nHot</code>.
By default, the component consists of a single pair of wells: one cold well and one warm well. The number of paired wells can be increased by modifing the parameters <code>nPai</code>.
The effect is a proportional increase of thermal capacity.
</p>
<p>
To ensure conservation of energy, the two wells are connected via fluid ports. To avoid thermal interferences, make sure that the aquifer domain radius <code>rMax</code> is large enough for your specific use case.
To ensure conservation of energy, the wells are connected via fluid ports. To avoid thermal interferences, make sure that the aquifer domain radius <code>rMax</code> is large enough for your specific use case.
</p>
<p>
Circulation pumps are included in the model and they can be controlled by acting on the input connector. The input must vary between [1,-1]. A positive value will circulate water
Expand All @@ -445,12 +454,6 @@ clockwise (extraction from the cold well and injection into the warm well). A ne
The temperature values in the warm and cold aquifers can be accessed using <code>TAquHot</code> and <code>TAquCol</code>. These temperatures correspond to the temperatures of each thermal capacitance
in the discretized domain. The location of the thermal capacitance is expressed by <code>rVol</code>.
</p>
<p>
The nominal pressure drops in the circuit must be selected according to the figure below.
</p>
<p align=\"center\">
<img alt=\"image\" src=\"modelica://IBPSA/Resources/Images/Fluid/Geothermal/Aquifer/PressureCircuit.png\">
</p>