This repository has been archived by the owner on Oct 4, 2021. It is now read-only.
1.9.5
[1.9.5] 30-04-2020
Added
- Solar Module SM200 support
- Support writing to Junkers FR100 thermostats
- Support writing to RC100, Moduline 1000/1010 thermostats
- MM10 Mixing module support (thanks @MichaelDvP)
- MM200 warm water circuits (#315)
- Support for Moduline 200 and Sieger ES72 thermostats
- First implementation of writing to generic Junker Thermostats (thanks @Neonox31)
- Added model type (Buderus, Sieger, Junkers, Nefit, Bosch, Worcester) to device names
set master_thermostat <product id>
to choose with thermostat is master when there are multiple on the busboiler wwonetime
command from Telnetset bus_id <ID>
to support multiple EMS-ESP circuits. Default is 0x0B to mimic a service key.mqtt_nestedjson
option to disable multiple data records being nested into a single JSON string- MQTT publish messages are queued and gracefully published every second to avoid TCP blocks
- Added features to WW messages (0x33, 0x34) to improve WW monitoring. (PR#338 by @ypaindaveine)
- Added mixing log and stub for EMS type 0xAC (PR#338 by @ypaindaveine)
- Added Thermostat retrieving settings (0xA5) (validated on RC30N) with MQTT support (thanks Yves @ypaindaveine. See #352)
- Merged with PR #366 from @MichaelDvP fixing RC20 and MM50
Fixed
- set boiler warm water temp on Junkers/Bosch HT3
- fixed detection of the Moduline 400 thermostat
- RC35 setting temperature also forces the current select temp to change, irrespective of the mode
Changed
- improved MQTT publishing to stop network flooding.
publish_time
of -1 is no publish, 0 is automatic otherwise its a time interval - External sensors (like Dallas DS18*) are sent as a nested MQTT topic including their unqiue identifier
mqttlog
console command renamed tomqttqueue
to only show the current publish queuestatus
payload on start-up shows the IP and Version of EMS-ESPthermostat mode
takes a string like manual,auto,heat,day,night,eco,comfort,holiday,nofrostthermostat temp
also takes a mode string, e.g.thermostat temp 20 heat
queue
renamed totxqueue
Removed
autodetect scan
. Replaced withdevices scan
anddevices scan+
for deep scanningmqttlog all