Fix stick calibration #22

Open
wants to merge 1 commit into
base: main
Choose a base branch
from
Open

Conversation

paranoidduck
Copy link

@paranoidduck paranoidduck commented Aug 9, 2024

I was experiencing issues #8 / #18 on my NSO N64 controler.
Digging in the code, I found that min/max calibration are not properly set during nx_con_read_stick_calibration().
Hence, it always returns EINVAL (because returned calibration values don't satisfy "min < center < max").

According to dekuNukem joycon reverse engineering, the min and max values read from SPI are relative to the center.

So the actual calibration values should be center-min < center < center+max.

@paranoidduck
Copy link
Author

paranoidduck commented Aug 10, 2024

Reading more carefully issue #8, I realize you had already identified the commit which introduced the regression. And that I've just reintroduced the missing lines with this PR.