fix(probe_geometry): bugfix in x_coords for probe with staggered electrode positions #181

Merged
merged 2 commits into from
Jan 12, 2024

Conversation

ttngu207
Copy link
Contributor

Fix a bug in generating x_coords for electrodes from probes with staggered electrode position design (e.g. npx 3A and 3B)
This bug is new, from the recent updates to handle new SpikeGLX version
First reported by Janet Wallace from SabatiniLab

@kushalbakshi kushalbakshi merged commit d65b70f into datajoint:staging Jan 12, 2024
7 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment