Skip to content

Commit

Permalink
Publish Version 0.0.15 with some doc updates
Browse files Browse the repository at this point in the history
  • Loading branch information
catsmanac committed Aug 23, 2023
1 parent 72a7f0f commit a480339
Show file tree
Hide file tree
Showing 3 changed files with 36 additions and 35 deletions.
65 changes: 33 additions & 32 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -117,39 +117,40 @@ A device `Envoy <serialnumber>` is created with sensor entities for accessible d

## Envoy Sensors

|Sensor name|Sensor ID|remarks|
|-----|-----|----|
|Envoy \<serialnumber\> Current Power Production|sensor.Envoy_\<serialnumber\>_current_power_production||
|Envoy \<serialnumber\> Today's Energy production|sensor.Envoy_\<serialnumber\>_todays_energy_production|1|
|Envoy \<serialnumber\> Last Seven Days Energy Production|sensor.Envoy_\<serialnumber\>_last_seven_days_energy_production|1|
|Envoy \<serialnumber\> Lifetime Energy Production|sensor.Envoy_\<serialnumber\>_lifetime_energy_production|2|
|Envoy \<serialnumber\> Current Power Consumption|sensor.Envoy_\<serialnumber\>_current_power_consumption||
|Envoy \<serialnumber\> Today's Energy Consumption|sensor.Envoy_\<serialnumber\>_todays_energy_consumption|4,5|
|Envoy \<serialnumber\> Last Seven Days Energy Consumption|sensor.Envoy_\<serialnumber\>_last_seven_days_energy_consumption|4,5|
|Envoy \<serialnumber\> Lifetime Energy Consumption|sensor.Envoy_\<serialnumber\>_lifetime_energy_consumption|4,5|
|Grid Status |binary_sensor.grid_status|3|
Envoy \<serialnumber\> Current Power Production L\<n\>|sensor.Envoy_\<serialnumber\>_current_power_production_L\<n\>|4,5|
|Envoy \<serialnumber\> Today's Energy production L\<n\>|sensor.Envoy_\<serialnumber\>_todays_energy_production_L\<n\>|4,5|
|Envoy \<serialnumber\> Last Seven Days Energy Production L\<n\>|sensor.Envoy_\<serialnumber\>_last_seven_days_energy_production L\<n\>|4,5|
|Envoy \<serialnumber\> Lifetime Energy Production L\<n\>|sensor.Envoy_\<serialnumber\>_lifetime_energy_consumption_L\<n\>|4,5|
|Envoy \<serialnumber\> Current Power Consumption L\<n\>|sensor.Envoy_\<serialnumber\>_current_power_consumption_L\<n\>|4,5|
|Envoy \<serialnumber\> Today's Energy Consumption L\<n\>|sensor.Envoy_\<serialnumber\>_todays_energy_consumption_L\<n\>|4,5|
|Envoy \<serialnumber\> Last Seven Days Energy Consumption L\<n\>|sensor.Envoy_\<serialnumber\>_last_seven_days_energy_production L\<n\>|4,5|
|Envoy \<serialnumber\> Lifetime Energy Consumption L\<n\>|sensor.Envoy_\<serialnumber\>_lifetime_energy_consumption_L\<n\>|4,5|

1 always zero for Envoy Metered without meters.
2 reportedly resets to zero when reaching ~1.92MWh for Envoy Metered without meters.
|Sensor name|Sensor ID|Units|remarks|
|-----|-----|----|----|
|Envoy \<sn\> Current Power Production|sensor.Envoy_\<sn\>_current_power_production|W||
|Envoy \<sn\> Today's Energy production|sensor.Envoy_\<sn\>_todays_energy_production|Wh|1|
|Envoy \<sn\> Last Seven Days Energy Production|sensor.Envoy_\<sn\>_last_seven_days_energy_production|Wh|1|
|Envoy \<sn\> Lifetime Energy Production|sensor.Envoy_\<sn\>_lifetime_energy_production|Wh|2|
|Envoy \<sn\> Current Power Consumption|sensor.Envoy_\<sn\>_current_power_consumption|W||
|Envoy \<sn\> Today's Energy Consumption|sensor.Envoy_\<sn\>_todays_energy_consumption|Wh|4,5|
|Envoy \<sn\> Last Seven Days Energy Consumption|sensor.Envoy_\<sn\>_last_seven_days_energy_consumption|Wh|4,5|
|Envoy \<sn\> Lifetime Energy Consumption|sensor.Envoy_\<sn\>_lifetime_energy_consumption|Wh|4,5|
|Grid Status |binary_sensor.grid_status|On/Off|3|
Envoy \<sn\> Current Power Production L\<n\>|sensor.Envoy_\<sn\>_current_power_production_L\<n\>|W|4,5|
|Envoy \<sn\> Today's Energy production L\<n\>|sensor.Envoy_\<sn\>_todays_energy_production_L\<n\>|Wh|4,5|
|Envoy \<sn\> Last Seven Days Energy Production L\<n\>|sensor.Envoy_\<sn\>_last_seven_days_energy_production L\<n\>|Wh|4,5|
|Envoy \<sn\> Lifetime Energy Production L\<n\>|sensor.Envoy_\<sn\>_lifetime_energy_consumption_L\<n\>|Wh|4,5|
|Envoy \<sn\> Current Power Consumption L\<n\>|sensor.Envoy_\<sn\>_current_power_consumption_L\<n\>|W|4,5|
|Envoy \<sn\> Today's Energy Consumption L\<n\>|sensor.Envoy_\<sn\>_todays_energy_consumption_L\<n\>|Wh|4,5,6|
|Envoy \<sn\> Last Seven Days Energy Consumption L\<n\>|sensor.Envoy_\<sn\>_last_seven_days_energy_consumption L\<n\>|Wh|4,5,6|
|Envoy \<sn\> Lifetime Energy Consumption L\<n\>|sensor.Envoy_\<sn\>_lifetime_energy_consumption_L\<n\>|Wh|4,5,6|

1 Always zero for Envoy Metered without meters.
2 Reportedly resets to zero when reaching ~1.92MWh for Envoy Metered without meters.
3 Not available on Legacy models and ENVOY Standard with recent firmware.
4 Only on Envoy metered with configured and connected meters.
5 L\<n\> L1,L2,L3, availability depends on which and how many meters are connected and configured.
6 Reportedly always zero on Envoy metered with Firmware D8.

## Inverter Sensors

For each inverter a sensor for current power production is created.

|Sensor name|Sensor ID|remarks|
|-----|-----|----|
|Envoy \<serialnumber\> Inverter \<serialnumber\>|sensor.Envoy_\<serialnumber\>\_Inverter_\<serialnumber\>|1|
|Sensor name|Sensor ID|UNits|remarks|
|-----|-----|----|----|
|Envoy \<sn\> Inverter \<sn\>|sensor.Envoy_\<sn\>\_Inverter_\<sn\>|W|1|

1: Not available on Legacy models

Expand All @@ -161,13 +162,13 @@ For each inverter a sensor for current power production is created.

For each battery a sensor for percent full is created as well as sensors for overall battery percentage, overall battery capacity, overall energy charged and discharged are created.

|Sensor name|Sensor ID|remarks|
|-----|-----|----|
|Envoy \<serialnumber\> Battery \<serialnumber\>|sensor.Envoy_\<serialnumber\>\_Battery_\<serialnumber\>|Unit: % 1|
|Envoy \<serialnumber\> Total Battery Percentage|sensor.Envoy_\<serialnumber\>\_total_battery_percentage|1|
|Envoy \<serialnumber\> Current Battery Capacity|sensor.Envoy_\<serialnumber\>\_current_battery_capacity|Wh 1|
|Envoy \<serialnumber\> Battery Energy Charged|sensor.Envoy_\<serialnumber\>\_battery_energy_charged|1|
|Envoy \<serialnumber\> Battery Energy Discharged|sensor.Envoy_\<serialnumber\>\_battery_energy_charged|1|
|Sensor name|Sensor ID|Units|remarks|
|-----|-----|----|----|
|Envoy \<sn\> Battery \<sn\>|sensor.Envoy_\<sn\>\_Battery_\<sn\>|%|1|
|Envoy \<sn\> Total Battery Percentage|sensor.Envoy_\<sn\>\_total_battery_percentage|%|1|
|Envoy \<sn\> Current Battery Capacity|sensor.Envoy_\<sn\>\_current_battery_capacity|Wh|1|
|Envoy \<sn\> Battery Energy Charged|sensor.Envoy_\<sn\>\_battery_energy_charged|Wh|1|
|Envoy \<sn\> Battery Energy Discharged|sensor.Envoy_\<sn\>\_battery_energy_charged|Wh|1|

1: Not available on Legacy models and ENVOYS-S Standard

Expand Down
4 changes: 2 additions & 2 deletions custom_components/enphase_envoy_custom/manifest.json
Original file line number Diff line number Diff line change
@@ -1,10 +1,10 @@
{
"domain": "enphase_envoy",
"name": "Enphase Envoy (DEV-TEST)",
"name": "Enphase Envoy (DEV)",
"documentation": "https://github.com/briancmpbll/home_assistant_custom_envoy#readme",
"requirements": ["envoy-utils"],
"codeowners": ["@briancmpbll"],
"config_flow": true,
"iot_class": "local_polling",
"version": "0.0.14"
"version": "0.0.15"
}
2 changes: 1 addition & 1 deletion hacs.json
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
{
"name": "Enphase Envoy (DEV-TEST)",
"name": "Enphase Envoy (DEV)",
"render_readme": true,
"content_in_root": false
}

0 comments on commit a480339

Please sign in to comment.