update milliseconds to microseconds #86

Open
wants to merge 1 commit into
base: master
Choose a base branch
from

Conversation

zjli-2019
Copy link

update milliseconds to microseconds

Copy link

@tkuschel tkuschel left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Unfortunately the function bme280_cal_meas_delay() gives milliseconds, and it would be also easy to change this function giving microseconds, so the scaling factor BME280_MEAS_SCALING_FACTOR would become obsolete. And the linux_userspace.c does not need to change. Just another commit request? So long nothing done here at Bosch. CR looks good.