electron-builder's NSIS installer - execute arbitrary code on the target machine (Windows only)
High severity
GitHub Reviewed
Published
Mar 2, 2024
in
electron-userland/electron-builder
•
Updated Mar 16, 2024
Description
Published to the GitHub Advisory Database
Mar 4, 2024
Reviewed
Mar 4, 2024
Published by the National Vulnerability Database
Mar 6, 2024
Last updated
Mar 16, 2024
Impact
Windows-Only: The NSIS installer makes a system call to open cmd.exe via NSExec in the
.nsh
installer script. NSExec by default searches the current directory of where the installer is located before searchingPATH
. This means that if an attacker can place a malicious executable file named cmd.exe in the same folder as the installer, the installer will run the malicious file.Patches
Fixed in electron-userland/electron-builder#8059
Workarounds
None, it executes at the installer-level before the app is present on the system, so there's no way to check if it exists in a current installer.
References
https://cwe.mitre.org/data/definitions/426.html
https://cwe.mitre.org/data/definitions/427