import array

# domain
DOMAIN = "helios_vallox_ventilation"

# default network address and port
DEFAULT_IP = "192.168.178.36"
DEFAULT_PORT = 502

# mapping for the four NTC5k temperature sensors
NTC5K_TEMPERATURES = array.array(
"i",
[
-74,-70,-66,-62,-59,-56,-54,-52,-50,-48,-47,-46,-44,-43,-42,-41,-40,-39,-38,-37,-36,
-35,-34,-33,-33,-32,-31,-30,-30,-29,-28,-28,-27,-27,-26,-25,-25,-24,-24,-23,-23,-22,
-22,-21,-21,-20,-20,-19,-19,-19,-18,-18,-17,-17,-16,-16,-16,-15,-15,-14,-14,-14,-13,
-13,-12,-12,-12,-11,-11,-11,-10,-10,-9,-9,-9,-8,-8,-8,-7,-7,-7,-6,-6,-6,-5,-5,-5,-4,
-4,-4,-3,-3,-3,-2,-2,-2,-1,-1,-1,-1,0,0,0,1,1,1,2,2,2,3,3,3,4,4,4,5,5,5,5,6,6,6,7,7,
7,8,8,8,9,9,9,10,10,10,11,11,11,12,12,12,13,13,13,14,14,14,15,15,15,16,16,16,17,17,
18,18,18,19,19,19,20,20,21,21,21,22,22,22,23,23,24,24,24,25,25,26,26,27,27,27,28,28,
29,29,30,30,31,31,32,32,33,33,34,34,35,35,36,36,37,37,38,38,39,40,40,41,41,42,43,43,
44,45,45,46,47,48,48,49,50,51,52,53,53,54,55,56,57,59,60,61,62,63,65,66,68,69,71,73,
75,77,79,81,82,86,90,93,97,100,100,100,100,100,100,100,100,100
]
)

# mapping for valid senders / receivers
BUS_ADDRESSES = {
"MB*": 0x10, # all mainboards
"MB1": 0x11, # mainboard 1
"FB*": 0x20, # alle remote controls
"FB1": 0x21, # remote control 1
"LON": 0x28, # LON bus module (if any)
"_HA": 0x2E, # this HA Python script; we are simulating a remote
"_SH": 0x2F # SmartHomeNG Python script; also simulating a remote
}

# mapping bits to fan speeds
FANSPEEDS = {
1: 1,
3: 2,
7: 3,
15: 4,
31: 5,
63: 6,
127: 7,
255: 8
}

# mapping error messages / faults
COMPONENT_FAULTS = {
5: 'Inlet air sensor fault',
6: 'CO2 Alarm',
7: 'Outside air sensor fault',
8: 'Exhaust air sensor fault',
9: 'Water coil frost warning',
10: 'Outlet air sensor fault'
}

# mapping for registers and coils
REGISTERS_AND_COILS = {
# Current fanspeed (EC300Pro: 1..8)
"fanspeed" : {"varid" : 0x29, 'type': 'fanspeed', 'bitposition': -1, 'read': True, 'write': True },
# Fanspeed after switching on
"initial_fanspeed" : {"varid" : 0xA9, 'type': 'fanspeed', 'bitposition': -1, 'read': True, 'write': True },
# Maximum settable fanspeed
"max_fanspeed" : {"varid" : 0xA5, 'type': 'fanspeed', 'bitposition': -1, 'read': True, 'write': True },
# NTC5K sensors: outside air temperature
"outside_temp" : {"varid" : 0x32, 'type': 'temperature', 'bitposition': -1, 'read': True, 'write': False },
# NTC5K sensors: supply air temperature
"inlet_temp" : {"varid" : 0x35, 'type': 'temperature', 'bitposition': -1, 'read': True, 'write': False },
# NTC5K sensors: extract / inside air temperature
"outlet_temp" : {"varid" : 0x34, 'type': 'temperature', 'bitposition': -1, 'read': True, 'write': False },
# NTC5K sensors: exhaust air temperature
"exhaust_temp" : {"varid" : 0x33, 'type': 'temperature', 'bitposition': -1, 'read': True, 'write': False },
# various coils in register 0xA3 that are displayed on the remote controls (0..3 read/write, 4..7 readonly)
# FB LED1: on/off Caution: Remotes will not be switched back on automatically; initial_fanspeed set if done manually.
"powerstate" : {"varid" : 0xA3, 'type': 'bit', 'bitposition': 0, 'read': True, 'write': True },
# FB LED2: CO2 warning
"co2_indicator" : {"varid" : 0xA3, 'type': 'bit', 'bitposition': 1, 'read': True, 'write': False },
# FB LED3: Humidity warning
"rh_indicator" : {"varid" : 0xA3, 'type': 'bit', 'bitposition': 2, 'read': True, 'write': False },
# FB LED4: 0 = summer mode with bypass, 1 = wintermode with heat regeneration (LED is on in winter mode)
"summer_winter_mode": {"varid" : 0xA3, 'type': 'bit', 'bitposition': 3, 'read': True, 'write': False },
# FB icon 1: "Clean filter" warning
"clean_filter" : {"varid" : 0xA3, 'type': 'bit', 'bitposition': 4, 'read': True, 'write': False },
# FB icon 2 2: Pre-/Post heating active
"post_heating_on" : {"varid" : 0xA3, 'type': 'bit', 'bitposition': 5, 'read': True, 'write': False },
# FB icon 3: Error / fault
"fault_detected" : {"varid" : 0xA3, 'type': 'bit', 'bitposition': 6, 'read': True, 'write': False },
# FB icon 4: Service request
"service_requested" : {"varid" : 0xA3, 'type': 'bit', 'bitposition': 7, 'read': True, 'write': False },
# Summer mode: Activate bypass from this temperature onwards if fresh air °C (outside) < extract air °C (inside)
"bypass_setpoint" : {"varid" : 0xAF, 'type': 'temperature', 'bitposition': -1, 'read': True, 'write': True },
# Activation temperature for pre / post heating
"preheat_setpoint" : {"varid" : 0xA7, 'type': 'temperature', 'bitposition': -1, 'read': True, 'write': True },
# Pre / post heating is off (0) / on (1)
"preheat_status" : {"varid" : 0x70, 'type': 'bit', 'bitposition': 7, 'read': True, 'write': True },
# Frost protection - switch off fresh air ventilator and heating below this temperature; -6 ... +15°C
"defrost_setpoint" : {"varid" : 0xA8, 'type': 'temperature', 'bitposition': -1, 'read': True, 'write': True },
# Frost protection hysteresis - when to switch it on again (defrost_setpoint + (this_value/3)) --> 0x03 = 1°C
"defrost_hysteresis": {"varid" : 0xB2, 'type': 'dec_special', 'bitposition': -1, 'read': True, 'write': True },
# Boost mode: 0=fireplace (ignition - no exhaust air in the first 15 minutes of boost); 1=normal boost mode
"boost_mode" : {"varid" : 0xAA, 'type': 'bit', 'bitposition': 5, 'read': True, 'write': True },
# Switch boost on for 45 minutes (set to 1; will be reset automatically)
"boost_on_switch" : {"varid" : 0x71, 'type': 'bit', 'bitposition': 5, 'read': True, 'write': True },
# Current boost status (off/on)
"boost_status" : {"varid" : 0x71, 'type': 'bit', 'bitposition': 6, 'read': True, 'write': False },
# Remaining minutes of boost if on
"boost_remaining" : {"varid" : 0x79, 'type': 'dec', 'bitposition': -1, 'read': True, 'write': False },
# Fresh air vetilator off; set to 1 to switch off; requires to be set twice
"input_fan_off" : {"varid" : 0x08, 'type': 'bit', 'bitposition': 3, 'read': True, 'write': True },
# Exhaust air vetilator off; set to 1 to switch off; requires to be set twice
"output_fan_off" : {"varid" : 0x08, 'type': 'bit', 'bitposition': 5, 'read': True, 'write': True },
# rpm of fresh air ventilator (65...100% - pneumatic calibration; default=100)
"input_fan_percent" : {"varid" : 0xB0, 'type': 'dec', 'bitposition': -1, 'read': True, 'write': True },
# rpm of exhaust air ventilator (65...100% - pneumatic calibration; default=100)
"output_fan_percent": {"varid" : 0xB1, 'type': 'dec', 'bitposition': -1, 'read': True, 'write': True },
# Service reminder interval in months (used after reset f service reminder)
"service_interval" : {"varid" : 0xA6, 'type': 'dec', 'bitposition': -1, 'read': True, 'write': True },
# Remaining months for current service reminder
"service_due_months": {"varid" : 0xAB, 'type': 'dec', 'bitposition': -1, 'read': True, 'write': True },
# Error / fault register. 0 = no fault. see COMPONENT_FAULTS below
"fault_number" : {"varid" : 0x36, 'type': 'dec', 'bitposition': -1, 'read': True, 'write': False }
}