Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

The initial calibration process never ends in some case, which blocks the application code to start. #34

Open
changtengfei opened this issue Jun 29, 2022 · 0 comments

Comments

@changtengfei
Copy link
Contributor

The HF_CLOCK_fine code (10) here https://github.com/PisterLab/scum-test-code/blob/develop/scm_v3c/optical.c#L164 should be larger to the HF_CLOCK_FINE code (20) here https://github.com/PisterLab/scum-test-code/blob/develop/scm_v3c/optical.c#L174.

otherwise in some case, the initial calibration will be never ends. i.e. #33

@changtengfei changtengfei changed the title The The initial calibration process never ends in some case, which blocks the application code to start. Jun 29, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

1 participant