Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

AGS does not enforce Maximum Temperature #280

Open
softwareengineerprogrammer opened this issue Aug 27, 2024 · 0 comments
Open

AGS does not enforce Maximum Temperature #280

softwareengineerprogrammer opened this issue Aug 27, 2024 · 0 comments
Labels
bug Something isn't working

Comments

@softwareengineerprogrammer
Copy link
Collaborator

Is AGS, True
Has Nonvertical Section, True
Multilaterals Cased, True
Well Geometry Configuration, 1, -- --U-loop (could be Eavor style)
Plant Lifetime, 40, -- -Years
Water Thermal Conductivity, 0.65
Total Nonvertical Length, 6000.0
Nonvertical Wellbore Diameter, 0.23495, -- ---m
Cylindrical Reservoir Radius of Effect Factor, 5.0
Closed Loop Calculation Start Year, 0.1
Number of Multilateral Sections, 6
Well Drilling Cost Correlation, 3, -- - [-] Use built-in well drilling cost correlation #3 = vertical open-hole, large diameter
Horizontal Well Drilling Cost Correlation, 1, -- - [-] Use built-in well drilling cost correlation #3 = vertical open-hole, large diameter
Reservoir Impedance, 1E-4, -- --assume a very low reservoir impedance since the working fluid is never in contact with the reservoir
Production Flow Rate per Well, 110, -- - [kg/s]
Injection Temperature, 60, -- ---C
Gradient 1, 60, -- -[deg.C/km]
Reservoir Depth, 8000 meter
Cylindrical Reservoir Input Depth, 8000 meter, -- ---km
Cylindrical Reservoir Output Depth, 8000 meter, -- ----km
Cylindrical Reservoir Length, 8000 meter, -- --km
Reservoir Model, 0, -- -simple cylinder reservoir model
Number of Production Wells, 1, -- -[-]
Number of Injection Wells, 1, -- -[-]
Ramey Production Wellbore Model, 0, -- - Should be 0 (disable) or 1 (enable)
Production Wellbore Temperature Drop, 0, -- - [deg.C]
Maximum Temperature, 375, -- - [deg.C]
Reservoir Volume Option, 4, -- - Should be 1 2 3 or 4. See manual for details.
Reservoir Volume, 1e9, -- - [m3] (required for reservoir volume option 3 and 4
Reservoir Heat Capacity, 1050, -- - [J/kg/K]
End-Use Option, 1, -- - [-] Electricity
Power Plant Type, 1, -- - [1] Subcritical ORC
Circulation Pump Efficiency, 0.8, -- - [-]
Plant Outlet Pressure, 68.95
Economic Model, 3, -- - Should be 1 (FCR model) 2 (Standard LCOE/LCOH model) or 3 (Bicycle model).
Fraction of Investment in Bonds, 0.65, -- - [-] Required if Bicycle model is selected. See manual for details.
Inflated Bond Interest Rate, 0.07, -- - [-] Required if Bicycle model is selected. See manual for details.
Inflated Equity Interest Rate, 0.12, -- - [-] Required if Bicycle model is selected. See manual for details.
Inflation Rate, 0.025, -- - [-] Required if Bicycle model is selected. See manual for details.
Combined Income Tax Rate, 0.392, -- - [-] Required if Bicycle model is selected. See manual for details.
Gross Revenue Tax Rate, 0, -- - [-] Required if Bicycle model is selected. See manual for details.
Reservoir Stimulation Capital Cost, 0, -- - [M$/injection well] Reservoir stimulation capital cost per injection well
Print Output to Console, 1, -- - [-] Should be 0 (don't print results to console) or 1 (print results to console)
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working
Projects
None yet
Development

No branches or pull requests

1 participant