Merge remote-tracking branch 'origin/develop' into vrfFluidCtrlFixCoo…
Browse files Browse the repository at this point in the history
…lingCycling
  • Loading branch information
Yujie Xu committed Jul 24, 2024
2 parents 6253ece + 8c96cbb commit f4c425b
Show file tree
Hide file tree
Showing 49 changed files with 5,898 additions and 7,299 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -1018,8 +1018,6 @@ \subsection{Equipment Summary}\label{equipment-summary}
Plantloop Branch Name
\end{itemize}

An example of the report is shown here

\begin{figure}[h!]
\centering
\includegraphics{media/boiler-table-example.PNG}
Expand Down Expand Up @@ -1053,8 +1051,6 @@ \subsection{Equipment Summary}\label{equipment-summary}
Condenser Loop Branch Name
\end{itemize}

An example of the report is shown here

\begin{figure}[h!]
\centering
\includegraphics{media/cooling-tower-table-example.PNG}
Expand All @@ -1078,8 +1074,6 @@ \subsection{Equipment Summary}\label{equipment-summary}
Minimum Loop Flow Rate [m3/s]
\end{itemize}

An example of the report is shown here

\begin{figure}[h!]
\centering
\includegraphics{media/plantloop-table-example.PNG}
Expand Down Expand Up @@ -1127,8 +1121,6 @@ \subsection{Equipment Summary}\label{equipment-summary}
Minimum Outdoor Flow Schedule Name
\end{itemize}

An example of the report is shown here

\begin{figure}[h!]
\centering
\includegraphics{media/air-terminal-table-example.PNG}
Expand Down Expand Up @@ -1160,67 +1152,13 @@ \subsection{Equipment Summary}\label{equipment-summary}
Outdoor Airflow [kg/s]
\end{itemize}

An example of the report is shown here

\begin{figure}[h!]
\centering
\includegraphics{media/air-heat-recovery-table-example.PNG}
\caption{}
\end{figure}

{\scriptsize
\begin{longtable}[c]{>{\raggedright}p{1.5in}>{\raggedright}p{1.5in}>{\raggedright}p{1.5in}>{\raggedright}p{1.5in}}
\toprule
~ & Type & Nominal Total Capacity (W) & Nominal Efficiency (W/W) \tabularnewline
~ & Type & Reference Capacity[W] & Type Reference Efficiency [W/W] & Rated Capacity [W] & Rated Efficiency [W/W] & IPLV in SI Units [W/W] & IPLV in IP Units [Btu/W-h] & Minimum Part Load Ratio & Fuel Type & Rated Entering Condenser Temperature [C] & Rated Leaving Evaporator Temperature [C] Reference Entering Condenser Temperature [C] Reference Leaving Evaporator Temperature [C] Design Size Reference Chilled Water Flow Rate [kg/s] Design Size Reference Condenser Fluid Flow Rate [kg/s] Plantloop Name Plantloop Branch Name Condenser Loop Name Condenser Loop Branch Name Heat Recovery Plantloop Name Heat Recovery Plantloop Branch Name Recovery Relative Capacity Fraction

\midrule
\endfirsthead

\toprule
~ & Type & Nominal Total Capacity (W) & Nominal Efficiency (W/W) \tabularnewline
\midrule
\endhead

Type Reference Capacity[W] TypeReference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h] Minimum Part Load Ratio Fuel Type Rated Entering Condenser Temperature [C] Rated Leaving Evaporator Temperature [C] Reference Entering Condenser Temperature [C] Reference Leaving Evaporator Temperature [C] Design Size Reference Chilled Water Flow Rate [kg/s] Design Size Reference Condenser Fluid Flow Rate [kg/s] Plantloop Name Plantloop Branch Name Condenser Loop Name Condenser Loop Branch Name Heat Recovery Plantloop Name Heat Recovery Plantloop Branch Name Recovery Relative Capacity Fraction
90.1-2004 WATERCOOLED CENTRIFUGAL CHILLER 0 416TONS 0.6KW/TON Chiller:Electric:EIR 1932343.27 6.10 1932343.27 6.10 6.88 6.92 0.00 Electricity 35.00 6.67 35.00 6.67 82.04 96.29 CHILLED WATER LOOP CHILLED WATER LOOP SUPPLY BRANCH 1 CONDENSER WATER LOOP CONDENSER WATER LOOP DEMAND BRANCH 2 N/A N/A 0.00
90.1-2004 WATERCOOLED CENTRIFUGAL CHILLER 1 416TONS 0.6KW/TON Chiller:Electric:EIR 1932343.27 6.10 1932343.27 6.10 6.88 6.92 0.00 Electricity 35.00 6.67 35.00 6.67 82.04 96.29 CHILLED WATER LOOP CHILLED WATER LOOP SUPPLY BRANCH 2 CONDENSER WATER LOOP CONDENSER WATER LOOP DEMAND BRANCH 3 N/A N/A 0.00






SPACE1-1 ZONE COIL & Coil:Heating:Fuel & 17614.83 & 0.80 \tabularnewline
SPACE2-1 ZONE COIL & Coil:Heating:Fuel & 14619.82 & 0.80 \tabularnewline
SPACE3-1 ZONE COIL & Coil:Heating:Fuel & 16093.74 & 0.80 \tabularnewline
SPACE4-1 ZONE COIL & Coil:Heating:Fuel & 18942.35 & 0.80 \tabularnewline
SPACE5-1 ZONE COIL & Coil:Heating:Fuel & 19146.73 & 0.80 \tabularnewline
MAIN HEATING COIL 1 & Coil:Heating:Fuel & 19754.61 & 0.80 \tabularnewline
\bottomrule
\end{longtable}}

{\scriptsize
\begin{longtable}[c]{>{\raggedright}p{1.5in}>{\raggedright}p{1.5in}>{\raggedright}p{1.5in}>{\raggedright}p{1.5in}}
\toprule
~ & Type & Nominal Total Capacity (W) & Nominal Efficiency (W/W) \tabularnewline
\midrule
\endfirsthead

\toprule
~ & Type & Nominal Total Capacity (W) & Nominal Efficiency (W/W) \tabularnewline
\midrule
\endhead

SPACE1-1 ZONE COIL & Coil:Heating:Fuel & 17614.83 & 0.80 \tabularnewline
SPACE2-1 ZONE COIL & Coil:Heating:Fuel & 14619.82 & 0.80 \tabularnewline
SPACE3-1 ZONE COIL & Coil:Heating:Fuel & 16093.74 & 0.80 \tabularnewline
SPACE4-1 ZONE COIL & Coil:Heating:Fuel & 18942.35 & 0.80 \tabularnewline
SPACE5-1 ZONE COIL & Coil:Heating:Fuel & 19146.73 & 0.80 \tabularnewline
MAIN HEATING COIL 1 & Coil:Heating:Fuel & 19754.61 & 0.80 \tabularnewline
\bottomrule
\end{longtable}}


\subsection{Envelope Summary}\label{envelope-summary}

Expand Down
2 changes: 1 addition & 1 deletion src/EnergyPlus/BoilerSteam.cc
Original file line number Diff line number Diff line change
Expand Up @@ -267,7 +267,7 @@ namespace BoilerSteam {
"Hot Steam Nodes");

if (SteamFluidIndex == 0 && BoilerNum == 1) {
SteamFluidIndex = FluidProperties::FindRefrigerant(state, fluidNameSteam);
SteamFluidIndex = FluidProperties::GetRefrigNum(state, fluidNameSteam); // Steam is a refrigerant?
if (SteamFluidIndex == 0) {
ShowSevereError(
state, format("{}{}=\"{}\",", RoutineName, state.dataIPShortCut->cCurrentModuleObject, state.dataIPShortCut->cAlphaArgs(1)));
Expand Down
2 changes: 1 addition & 1 deletion src/EnergyPlus/ChillerAbsorption.cc
Original file line number Diff line number Diff line change
Expand Up @@ -385,7 +385,7 @@ void GetBLASTAbsorberInput(EnergyPlusData &state)
state.dataIPShortCut->cAlphaArgs(7),
"Hot Water Nodes");
} else {
thisChiller.SteamFluidIndex = FluidProperties::FindRefrigerant(state, fluidNameSteam);
thisChiller.SteamFluidIndex = FluidProperties::GetRefrigNum(state, fluidNameSteam);
thisChiller.GeneratorInletNodeNum = NodeInputManager::GetOnlySingleNode(state,
state.dataIPShortCut->cAlphaArgs(6),
ErrorsFound,
Expand Down
2 changes: 1 addition & 1 deletion src/EnergyPlus/ChillerIndirectAbsorption.cc
Original file line number Diff line number Diff line change
Expand Up @@ -396,7 +396,7 @@ void GetIndirectAbsorberInput(EnergyPlusData &state)
state.dataIPShortCut->cAlphaArgs(10),
"Hot Water Nodes");
} else {
thisChiller.SteamFluidIndex = FluidProperties::FindRefrigerant(state, fluidNameSteam);
thisChiller.SteamFluidIndex = FluidProperties::GetRefrigNum(state, fluidNameSteam);
thisChiller.GeneratorInletNodeNum = NodeInputManager::GetOnlySingleNode(state,
state.dataIPShortCut->cAlphaArgs(9),
ErrorsFound,
Expand Down
2 changes: 1 addition & 1 deletion src/EnergyPlus/Data/EnergyPlusData.cc
Original file line number Diff line number Diff line change
Expand Up @@ -117,7 +117,7 @@ EnergyPlusData::EnergyPlusData()
this->dataFans = std::make_unique<FansData>();
this->dataFaultsMgr = std::make_unique<FaultsManagerData>();
this->dataFluidCoolers = std::make_unique<FluidCoolersData>();
this->dataFluidProps = std::make_unique<FluidPropertiesData>();
this->dataFluidProps = std::make_unique<FluidData>();
this->dataFourPipeBeam = std::make_unique<FourPipeBeamData>();
this->dataFuelCellElectGen = std::make_unique<FuelCellElectricGeneratorData>();
this->dataFurnaces = std::make_unique<FurnacesData>();
Expand Down
4 changes: 2 additions & 2 deletions src/EnergyPlus/Data/EnergyPlusData.hh
Original file line number Diff line number Diff line change
Expand Up @@ -134,7 +134,7 @@ struct FanCoilUnitsData;
struct FansData;
struct FaultsManagerData;
struct FluidCoolersData;
struct FluidPropertiesData;
struct FluidData;
struct FourPipeBeamData;
struct FuelCellElectricGeneratorData;
struct FurnacesData;
Expand Down Expand Up @@ -390,7 +390,7 @@ struct EnergyPlusData : BaseGlobalStruct
std::unique_ptr<FansData> dataFans;
std::unique_ptr<FaultsManagerData> dataFaultsMgr;
std::unique_ptr<FluidCoolersData> dataFluidCoolers;
std::unique_ptr<FluidPropertiesData> dataFluidProps;
std::unique_ptr<FluidData> dataFluidProps;
std::unique_ptr<FourPipeBeamData> dataFourPipeBeam;
std::unique_ptr<FuelCellElectricGeneratorData> dataFuelCellElectGen;
std::unique_ptr<FurnacesData> dataFurnaces;
Expand Down
Loading

5 comments on commit f4c425b

@nrel-bot-3
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfFluidCtrlFixCoolingCycling (Unknown) - x86_64-MacOS-10.18-clang-15.0.0: OK (3640 of 3644 tests passed, 0 test warnings)

Messages:\n

  • 4 tests had: ERR diffs.
  • 4 tests had: ESO big diffs.
  • 4 tests had: Table big diffs.
  • 1 test had: Table string diffs.
  • 2 tests had: MTR big diffs.
  • 1 test had: EIO diffs.

Failures:\n

regression Test Summary

  • Passed: 787
  • Failed: 4

Build Badge Test Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfFluidCtrlFixCoolingCycling (Unknown) - Win64-Windows-10-VisualStudio-16: OK (2852 of 2852 tests passed, 0 test warnings)

Build Badge Test Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfFluidCtrlFixCoolingCycling (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4: OK (3681 of 3685 tests passed, 0 test warnings)

Messages:\n

  • 4 tests had: ERR diffs.
  • 4 tests had: ESO big diffs.
  • 4 tests had: Table big diffs.
  • 1 test had: Table string diffs.
  • 2 tests had: MTR big diffs.
  • 1 test had: EIO diffs.

Failures:\n

regression Test Summary

  • Passed: 807
  • Failed: 4

Build Badge Test Badge

@nrel-bot-2c
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfFluidCtrlFixCoolingCycling (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-UnitTestsCoverage-Debug: OK (2060 of 2060 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfFluidCtrlFixCoolingCycling (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-IntegrationCoverage-Debug: OK (795 of 795 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

Please sign in to comment.