fix unit test Fan:VariableVolume to Fan:SystemModel transition
Browse files Browse the repository at this point in the history
  • Loading branch information
Yujie Xu committed Jul 24, 2024
1 parent 7dd6720 commit 19c4aae
Show file tree
Hide file tree
Showing 2 changed files with 268 additions and 151 deletions.
102 changes: 70 additions & 32 deletions tst/EnergyPlus/unit/AirTerminalSingleDuctMixer.unit.cc
Original file line number Diff line number Diff line change
Expand Up @@ -3405,7 +3405,7 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimVRFfluidCntrl_ATMInletSi
" 0, !- Outdoor Air Flow Rate When No Cooling or Heating is Needed {m3/s}",
" VRFFanSchedule, !- Supply Air Fan Operating Mode Schedule Name",
" drawthrough, !- Supply Air Fan Placement",
" Fan:VariableVolume, !- Supply Air Fan Object Type",
" Fan:SystemModel, !- Supply Air Fan Object Type",
" TU1 VRF Supply Fan, !- Supply Air Fan Object Name",
" , !- Outside Air Mixer Object Type",
" , !- Outside Air Mixer Object Name",
Expand All @@ -3416,26 +3416,43 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimVRFfluidCntrl_ATMInletSi
" 30, !- Zone Terminal Unit On Parasitic Electric Energy Use {W}",
" 20; !- Zone Terminal Unit Off Parasitic Electric Energy Use {W}",

" Fan:VariableVolume,",
" Fan:SystemModel,",
" TU1 VRF Supply Fan, !- Name",
" VRFAvailSched, !- Availability Schedule Name",
" 0.7, !- Fan Total Efficiency",
" 600, !- Pressure Rise {Pa}",
" 0.500, !- Maximum Flow Rate {m3/s}",
" Fraction, !- Fan Power Minimum Flow Rate Input Method",
" 0, !- Fan Power Minimum Flow Fraction",
" 0, !- Fan Power Minimum Air Flow Rate {m3/s}",
" 0.9, !- Motor Efficiency",
" 1, !- Motor In Airstream Fraction",
" 0.059, !- Fan Power Coefficient 1",
" 0, !- Fan Power Coefficient 2",
" 0, !- Fan Power Coefficient 3",
" 0.928, !- Fan Power Coefficient 4",
" 0, !- Fan Power Coefficient 5",
" TU1 VRF DX HCoil Outlet Node, !- Air Inlet Node Name",
" TU1 Outlet Node, !- Air Outlet Node Name",
" 0.500, !- Design Maximum Air Flow Rate {m3/s}",
" Continuous, !- Speed Control Method",
" 0.0, !- Electric Power Minimum Flow Rate Fraction",
" 600, !- Design Pressure Rise {Pa}",
" 0.9, !- Motor Efficiency",
" 1.0, !- Motor In Air Stream Fraction",
" autosize, !- Design Electric Power Consumption {W}",
" TotalEfficiencyAndPressure, !- Design Power Sizing Method",
" , !- Electric Power Per Unit Flow Rate {W/(m3/s)}",
" , !- Electric Power Per Unit Flow Rate Per Unit Pressure {W/((m3/s)-Pa)}",
" 0.7, !- Fan Total Efficiency",
" TU1 Fan Power Curve, !- Electric Power Function of Flow Fraction Curve Name",
" ,",
" ,",
" ,",
" ,",
" General; !- End-Use Subcategory",

" Curve:Quartic,",
" TU1 Fan Power Curve , !- Name",
" 0.059, !- Coefficient1 Constant",
" 0, !- Coefficient2 x ",
" 0, !- Coefficient3 x**2 ",
" 0.928, !- Coefficient4 x**3 ",
" 0, !- Coefficient5 x**4 ",
" 0.0, !- Minimum Value of x",
" 1.0, !- Maximum Value of x",
" 0.0, !- Minimum Curve Output",
" 1.0, !- Maximum Curve Output",
" Dimensionless, !- Input Unit Type for X",
" Dimensionless; !- Output Unit Type",

" Coil:Heating:DX:VariableRefrigerantFlow:FluidTemperatureControl,",
" TU1 VRF DX Heating Coil, !- Name",
" VRFAvailSched, !- Availability Schedule",
Expand Down Expand Up @@ -5063,6 +5080,8 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimVRFfluidCntrl_ATMInletSi

// set secondary air mass flow rate to zero
state->dataLoopNodes->Node(state->dataSingleDuct->SysATMixer(1).SecInNode).MassFlowRate = 0.0;
state->dataFans->fans(1)->set_size(*state); // add sizing
state->dataHVACVarRefFlow->VRF(1).VRFCondCyclingRatio = 1.0;
// Simulate zoneHVAC equipment (VRF terminal unit)
SimVRF(*state, VRFTUNum, FirstHVACIteration, OnOffAirFlowRatio, QUnitOutVRFTU, LatOutputProvided, QZnReq);

Expand Down Expand Up @@ -5164,7 +5183,7 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimVRFfluidCntrl_ATMSupplyS
" 0, !- Outdoor Air Flow Rate When No Cooling or Heating is Needed {m3/s}",
" VRFFanSchedule, !- Supply Air Fan Operating Mode Schedule Name",
" drawthrough, !- Supply Air Fan Placement",
" Fan:VariableVolume, !- Supply Air Fan Object Type",
" Fan:SystemModel, !- Supply Air Fan Object Type",
" TU1 VRF Supply Fan, !- Supply Air Fan Object Name",
" , !- Outside Air Mixer Object Type",
" , !- Outside Air Mixer Object Name",
Expand All @@ -5175,26 +5194,43 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimVRFfluidCntrl_ATMSupplyS
" 30, !- Zone Terminal Unit On Parasitic Electric Energy Use {W}",
" 20; !- Zone Terminal Unit Off Parasitic Electric Energy Use {W}",

" Fan:VariableVolume,",
" Fan:SystemModel,",
" TU1 VRF Supply Fan, !- Name",
" VRFAvailSched, !- Availability Schedule Name",
" 0.7, !- Fan Total Efficiency",
" 600, !- Pressure Rise {Pa}",
" 0.500, !- Maximum Flow Rate {m3/s}",
" Fraction, !- Fan Power Minimum Flow Rate Input Method",
" 0, !- Fan Power Minimum Flow Fraction",
" 0, !- Fan Power Minimum Air Flow Rate {m3/s}",
" 0.9, !- Motor Efficiency",
" 1, !- Motor In Airstream Fraction",
" 0.059, !- Fan Power Coefficient 1",
" 0, !- Fan Power Coefficient 2",
" 0, !- Fan Power Coefficient 3",
" 0.928, !- Fan Power Coefficient 4",
" 0, !- Fan Power Coefficient 5",
" TU1 VRF DX HCoil Outlet Node, !- Air Inlet Node Name",
" SPACE1-1 AIR TERMINAL MIXER SECONDARY INLET, !- Air Outlet Node Name",
" 0.500, !- Design Maximum Air Flow Rate {m3/s}",
" Continuous, !- Speed Control Method",
" 0.0, !- Electric Power Minimum Flow Rate Fraction",
" 600, !- Design Pressure Rise {Pa}",
" 0.9, !- Motor Efficiency",
" 1.0, !- Motor In Air Stream Fraction",
" autosize, !- Design Electric Power Consumption {W}",
" TotalEfficiencyAndPressure, !- Design Power Sizing Method",
" , !- Electric Power Per Unit Flow Rate {W/(m3/s)}",
" , !- Electric Power Per Unit Flow Rate Per Unit Pressure {W/((m3/s)-Pa)}",
" 0.7, !- Fan Total Efficiency",
" TU1 Fan Power Curve, !- Electric Power Function of Flow Fraction Curve Name",
" ,",
" ,",
" ,",
" ,",
" General; !- End-Use Subcategory",

" Curve:Quartic,",
" TU1 Fan Power Curve , !- Name",
" 0.059, !- Coefficient1 Constant",
" 0, !- Coefficient2 x ",
" 0, !- Coefficient3 x**2 ",
" 0.928, !- Coefficient4 x**3 ",
" 0, !- Coefficient5 x**4 ",
" 0.0, !- Minimum Value of x",
" 1.0, !- Maximum Value of x",
" 0.0, !- Minimum Curve Output",
" 1.0, !- Maximum Curve Output",
" Dimensionless, !- Input Unit Type for X",
" Dimensionless; !- Output Unit Type",

" Coil:Heating:DX:VariableRefrigerantFlow:FluidTemperatureControl,",
" TU1 VRF DX Heating Coil, !- Name",
" VRFAvailSched, !- Availability Schedule",
Expand Down Expand Up @@ -6817,6 +6853,8 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimVRFfluidCntrl_ATMSupplyS

state->dataScheduleMgr->Schedule(state->dataHVACVarRefFlow->VRFTU(VRFTUNum).SchedPtr).CurrentValue = 1.0; // unit is always available
state->dataScheduleMgr->Schedule(state->dataHVACVarRefFlow->VRFTU(VRFTUNum).FanAvailSchedPtr).CurrentValue = 1.0; // fan is always available
state->dataHVACVarRefFlow->VRF(1).VRFCondCyclingRatio = 1.0;
state->dataFans->fans(1)->set_size(*state); // add fan sizing

// set secondary air mass flow rate to zero
state->dataLoopNodes->Node(state->dataSingleDuct->SysATMixer(1).SecInNode).MassFlowRate = 0.0;
Expand All @@ -6829,8 +6867,8 @@ TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimVRFfluidCntrl_ATMSupplyS
// check the terminal air mixer outlet flow rate must be equal to the mass flow rate of VRFTU + the primary air
ATMixerOutletMassFlowRate = SecondaryAirMassFlowRate + PrimaryAirMassFlowRate;
ASSERT_EQ(ATMixerOutletMassFlowRate, state->dataSingleDuct->SysATMixer(1).MixedAirMassFlowRate);
// check the cooling output delivered is within 2.0 Watt of zone cooling load
ASSERT_NEAR(QZnReq, QUnitOutVRFTU, 2.0);
// changed the threshold from 2 to 3 as the fan was changed from hard-sized to autosize, a little more error is expected
ASSERT_NEAR(QZnReq, QUnitOutVRFTU, 3.0);
}

TEST_F(EnergyPlusFixture, AirTerminalSingleDuctMixer_SimUnitVent_ATMInletSide)
Expand Down
Loading

5 comments on commit 19c4aae

@nrel-bot-3
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfCoolingFan (Unknown) - x86_64-MacOS-10.18-clang-15.0.0: OK (3639 of 3644 tests passed, 48 test warnings)

Messages:\n

  • 27 tests had: ESO small diffs.
  • 16 tests had: MTR small diffs.
  • 15 tests had: EIO diffs.
  • 11 tests had: Table small diffs.
  • 30 tests had: ERR diffs.
  • 5 tests had: Table string diffs.
  • 4 tests had: AUD diffs.
  • 4 tests had: BND diffs.
  • 1 test had: MDD diffs.
  • 1 test had: MTD diffs.
  • 4 tests had: Table big diffs.
  • 1 test had: IDF diffs.
  • 2 tests had: ESO big diffs.
  • 1 test had: MTR big diffs.

Failures:\n

regression Test Summary

  • Passed: 786
  • Failed: 5

Build Badge Test Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfCoolingFan (Unknown) - Win64-Windows-10-VisualStudio-16: OK (2852 of 2852 tests passed, 0 test warnings)

Build Badge Test Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfCoolingFan (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4: OK (3678 of 3685 tests passed, 47 test warnings)

Messages:\n

  • 15 tests had: EIO diffs.
  • 28 tests had: ESO small diffs.
  • 14 tests had: MTR small diffs.
  • 10 tests had: Table small diffs.
  • 30 tests had: ERR diffs.
  • 7 tests had: Table string diffs.
  • 3 tests had: ESO big diffs.
  • 5 tests had: Table big diffs.
  • 4 tests had: AUD diffs.
  • 4 tests had: BND diffs.
  • 1 test had: MDD diffs.
  • 1 test had: MTD diffs.
  • 1 test had: IDF diffs.
  • 1 test had: MTR big diffs.

Failures:\n

regression Test Summary

  • Passed: 804
  • Failed: 7

Build Badge Test Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfCoolingFan (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-UnitTestsCoverage-Debug: OK (2060 of 2060 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

@nrel-bot-2c
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

vrfCoolingFan (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-IntegrationCoverage-Debug: OK (795 of 795 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

Please sign in to comment.