# Copyright 2019-2020 Hewlett Packard Enterprise Development LP
#
# This config file describes CAPMC operational configuration parameters.
#

# The NodeRules section describes rules/guidelines for CAPMC node control.
# The get_note_rules API returns these values.
[NodeRules]

# Minimum time, in seconds, which a node must reamin in the off state
# after a shutdown and power off operation. Use -1 for no limit.
MinOffTime = -1

# Maximum time, in seconds, which a node may be in the off state. Use -1
# for no limit.
MaxOffTime = -1

# The NodeRules.Off subsection describes rules/guidelines for node_off.
[NodeRules.Off]

# Approximate time, in seconds, for a node cleanly shutdown and power off.
Latency = 60

# Maximum number of nodes which may be powered off at once. Use -1 for no limit.
MaxRequest = -1

# The NodeRules.On subsection describes rules/guidelines for node_on.
[NodeRules.On]

# Approximate time, in seconds, for a node to power on and boot to Ready state.
Latency = 120

# Maximum number of nodes which may be powered on at once. Use -1 for no limit.
MaxRequest = -1

# The NodeRules.Reinit subsection describes rules/guidelines for node_reint.
[NodeRules.Reinit]

# Approximate time, in seconds, for a node cleanly shutdown, power off, power
# on, and boot to Ready state.
Latency = 180

# Maximum number of nodes allowed to be included in a node reinit request.
# Use -1 for no limit.
MaxRequest = -1

# The PowerControls section describes guidelines/policy/rules applying
# generally to CAPMC power off (down) / on (up) of hardware. These values
# should only be edited under direction from Cray service personnel.
[PowerControls]

# The PowerControls.ForceOff subsection describes guidelines/policy/rules
# applying to a force off action.
[PowerControls.ForceOff]

# Block components with these roles from power force off actions.
# BlockRole = ["Management"]

# An ordered list desribing the power force off sequence for components.
ComponentSequence = ["Node", "ComputeModule", "HSNBoard", "RouterModule", "Chassis", "CabinetPDUOutlet", "CabinetPDUPowerConnector"]

# Mapping of CAPMC force off to Redfish ResetType.
ResetType = ["ForceOff"]

# The PowerControls.ForceOn subsection describes guidelines/policy/rules
# applying to a force on action.
[PowerControls.ForceOn]

# Block components with these roles from power force on actions.
# BlockRole = ["Management"]

# An ordered list desribing the power force on sequence for components.
ComponentSequence = ["CabinetPDUPowerConnector", "CabinetPDUOutlet", "Chassis", "RouterModule", "HSNBoard", "ComputeModule", "Node"]

# Mapping of CAPMC force on to Redfish ResetType.
ResetType = ["ForceOn"]

# The PowerControls.ForceRestart subsection describes guidelines/policy/rules
# applying to a force restart (reinit) action.
[PowerControls.ForceRestart]

# Block components with these roles from power force restart actions.
# BlockRole = ["Management"]

# An ordered list desribing the power force restart sequence for components.
ComponentSequence = ["Node"]

# Mapping of CAPMC force restart (reinit) to Redfish ResetType.
ResetType = ["ForceRestart", "PowerCycle"]

# The PowerControls.off subsection describes guidelines/policy/rules
# applying to an off action.
[PowerControls.Off]

# Block components with these roles from power off actions.
# BlockRole = ["Management"]

# An ordered list desribing the power off sequence for components.
ComponentSequence = ["Node", "ComputeModule", "HSNBoard", "RouterModule", "Chassis", "CabinetPDUOutlet", "CabinetPDUPowerConnector"]

# Mapping of CAPMC (graceful) off to Redfish ResetType.
ResetType = ["GracefulShutdown", "PushPowerButton", "Off"]

# The PowerControls.On subsection describes guidelines/policy/rules
# applying to an on action.
[PowerControls.On]

# Block components with these roles from power on actions.
# BlockRole = ["Management"]

# An ordered list desribing the power on sequence for components.
ComponentSequence = ["CabinetPDUPowerConnector", "CabinetPDUOutlet", "Chassis", "RouterModule", "HSNBoard", "ComputeModule", "Node"]

# Mapping of CAPMC (graceful) on to Redfish ResetType.
ResetType = ["On"]

# The PowerControls.Resetart subsection describes guidelines/policy/rules
# applying to a restart (AKA reinit) action.
[PowerControls.Restart]

# Block components with these roles from power restart actions.
# BlockRole = ["Management"]

# An ordered list desribing the power restart sequence for components.
ComponentSequence = ["Node"]

# Mapping of CAPMC (graceful) restart to Redfish ResetType.
ResetType = ["GracefulRestart"]

# NOTE NMI is a future CAPMC enhancement. Actual configuration TBD.
[PowerControls.NMI]

# Block components with these roles from a NMI action.
# NOTE: "" covers any component without an assigned role.
# BlockRole = ["Management"]

# An ordered list desribing the NMI sequence for components.
ComponentSequence = ["Node"]

# Mapping of CAPMC NMI to Redfish ResetType.
ResetType = ["Nmi"]

[SystemParameters]

# Administratively defined upper limit on system power
PowerCapTarget = 0

# System power level, which if crossed, will result in Cray management software
# emitting over power budget warnings
PowerThreshold = 0

# Additional static system wide power overhead which is unreported, specified
# in watts
StaticPower = 0

# True if out-of-band HSS power ramp rate limiting features are enabled
RampLimited = false

# Administratively defined maximum rate of change (increasing or decreasing) in
# system wide power consumption, specified in watts per minute
RampLimit = 2000000

# Administratively defined minimum allowable system power consumption,
# specified in watts
PowerBandMin = 0

# Administratively defined maximum allowable system power consumption,
# specified in watts
PowerBandMax = 0

[CapmcConfiguration]

# Number of workers that are available to execute in parallel for Redfish calls
# ActionMaxWorkers = 1000

# CAPMC behavior for a power action that target hardware does not support
# Valid options: simulate, ignore, error
# simulate - For components that do not support GracefulRestart or
# ForceRestart, simulate will turn the node Off then On again
# ignore - Skip the component but notify the user it was ignored
# error - Halt the power operation and notify the user
# OnUnsupportedAction = "simulate"

# CAPMC will check power state of components when an Off request has been
# issued. CAPMC will return from the Off request when it has verified that the
# target components are off or if the number of retries have been exceeded.
# WaitForOffRetries = 4
# Amount of time to sleep between checks of component power state for Off.
# WaitForOffSleep = 15