9 changes: 9 additions & 0 deletions bricksrc/definitions.csv
Original file line number Diff line number Diff line change
Expand Up @@ -68,6 +68,7 @@ https://brickschema.org/schema/Brick#Blowdown_Water,Water expelled from a system
https://brickschema.org/schema/Brick#Boiler,"A closed, pressure vessel that uses fuel or electricity for heating water or other fluids to supply steam or hot water for heating, humidification, or other applications.",
https://brickschema.org/schema/Brick#Boiler_Command,A command to control a boiler,
https://brickschema.org/schema/Brick#Booster_Fan,Fan activated to increase airflow beyond what is provided by the default configuration,
https://brickschema.org/schema/Brick#Booster_Pump,"Used to increase the pressure and flow of a fluid, typically water, in a system to ensure adequate supply where needed.",
https://brickschema.org/schema/Brick#Box_Mode_Command,,
https://brickschema.org/schema/Brick#Break_Room,A space for people to relax while not working,
https://brickschema.org/schema/Brick#Breaker_Panel,Breaker Panel distributes power into various end-uses.,
Expand Down Expand Up @@ -113,6 +114,8 @@ https://brickschema.org/schema/Brick#Centrifugal_Chiller,A chiller that uses the
https://brickschema.org/schema/Brick#Change_Filter_Alarm,An alarm that indicates that a filter must be changed,
https://brickschema.org/schema/Brick#Chilled_Beam,"A device with an integrated coil that performs sensible heating of a space via circulation of room air. Chilled Beams are not designed to perform latent cooling; see Induction Units. Despite their name, Chilled Beams may perform heating or cooling of a space depending on their configuration.",
https://brickschema.org/schema/Brick#Chilled_Water,water used as a cooling medium (particularly in air-conditioning systems or in processes) at below ambient temperature.,
https://brickschema.org/schema/Brick#Chilled_Water_Booster_Pump,Used to increase the pressure and flow of chilled water in a system to ensure adequate supply where needed.,
https://brickschema.org/schema/Brick#Chilled_Water_Circulator_Pump,"Used to move chilled water in a closed circuit, ensuring continuous flow.",
https://brickschema.org/schema/Brick#Chilled_Water_Coil,"A cooling element made of pipe or tube that removes heat from equipment, machines or airflows that is filled with chilled water.",
https://brickschema.org/schema/Brick#Chilled_Water_Differential_Pressure_Deadband_Setpoint,Sets the size of a deadband of differential pressure of chilled water,
https://brickschema.org/schema/Brick#Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,
Expand All @@ -139,6 +142,7 @@ https://brickschema.org/schema/Brick#Chilled_Water_Thermal_Energy_Storage_Tank,"
https://brickschema.org/schema/Brick#Chilled_Water_Thermal_Expansion_Tank,A thermal expansion tank designed specifically for chilled water systems.,
https://brickschema.org/schema/Brick#Chilled_Water_Valve,A valve that modulates the flow of chilled water,
https://brickschema.org/schema/Brick#Chiller,Refrigerating machine used to transfer heat between fluids. Chillers are either direct expansion with a compressor or absorption type.,
https://brickschema.org/schema/Brick#Circulator_Pump,"Used to move hot or cold water in a closed circuit, ensuring continuous fluid flow.",
https://brickschema.org/schema/Brick#Cloudage,The fraction of the sky obscured by clouds when observed from a particular location,
https://brickschema.org/schema/Brick#Coil,Cooling or heating element made of pipe or tube that may or may not be finned and formed into helical or serpentine shape (ASHRAE Dictionary),
https://brickschema.org/schema/Brick#Cold_Box,"in a gas separation unit, the insulated section that contains the low-temperature heat exchangers and distillation columns.",
Expand All @@ -162,7 +166,9 @@ https://brickschema.org/schema/Brick#Condensate_Leak_Alarm,An alarm that indicat
https://brickschema.org/schema/Brick#Condenser,A heat exchanger in which the primary heat transfer vapor changes its state to a liquid phase.,
https://brickschema.org/schema/Brick#Condenser_Heat_Exchanger,A heat exchanger in which the primary heat transfer vapor changes its state to a liquid phase.,
https://brickschema.org/schema/Brick#Condenser_Water,Water used used to remove heat through condensation,
https://brickschema.org/schema/Brick#Condenser_Water_Booster_Pump,Used to increase the pressure and flow of condenser water in a system to ensure adequate supply where needed.,
https://brickschema.org/schema/Brick#Condenser_Water_Bypass_Valve,A valve installed in a bypass line of a condenser water loop,
https://brickschema.org/schema/Brick#Condenser_Water_Circulator_Pump,"Used to move chilled water in a closed circuit, ensuring continuous flow.",
https://brickschema.org/schema/Brick#Condenser_Water_Flow_Sensor,Measures the flow of the condenser water,
https://brickschema.org/schema/Brick#Condenser_Water_Isolation_Valve,An isolation valve installed in the condenser water loop,
https://brickschema.org/schema/Brick#Condenser_Water_Pump,A pump that is part of a condenser system; the pump circulates condenser water from the chiller back to the cooling tower,
Expand Down Expand Up @@ -295,6 +301,7 @@ https://brickschema.org/schema/Brick#Discharge_Fan_Differential_Speed_Setpoint,,
https://brickschema.org/schema/Brick#Disconnect_Switch,Building power is most commonly provided by utility company through a master disconnect switch (sometimes called a service disconnect) in the main electrical room of a building. The Utility Company provided master disconnect switch often owns or restricts access to this switch. There can also be other cases where a disconnect is placed into an electrical system to allow service cut-off to a portion of the building.,
https://brickschema.org/schema/Brick#Displacement_Flow_Air_Diffuser,An air diffuser that is designed for low discharge air speeds to minimize turbulence and induction of room air. This diffuser is used with displacement ventilation systems.,
https://brickschema.org/schema/Brick#Distribution_Frame,"A class of spaces where the cables carrying signals meet and connect, e.g. a wiring closet or a broadcast downlink room",
https://brickschema.org/schema/Brick#Domestic_Hot_Water_Circulator_Pump,"Used to move domestic hot water in a closed circuit, ensuring continuous flow.",
https://brickschema.org/schema/Brick#Domestic_Hot_Water_System,"The equipment, devices and conduits that handle the production and distribution of domestic hot water in a building",
https://brickschema.org/schema/Brick#Domestic_Hot_Water_System_Enable_Command,Enables operation of the domestic hot water system,
https://brickschema.org/schema/Brick#Domestic_Hot_Water_Temperature_Setpoint,Sets temperature of domestic hot water,
Expand Down Expand Up @@ -518,6 +525,8 @@ https://brickschema.org/schema/Brick#Hot_Box,hot air chamber forming part of an
https://brickschema.org/schema/Brick#Hot_Deck,Part of a dual duct air handling unit that supplies heating to a building,
https://brickschema.org/schema/Brick#Hot_Water,Hot water used for HVAC heating or supply to hot taps,
https://brickschema.org/schema/Brick#Hot_Water_Baseboard_Radiator,Hydronic heating device located at or near the floor,
https://brickschema.org/schema/Brick#Hot_Water_Booster_Pump,Used to increase the pressure and flow of hot water in a system to ensure adequate supply where needed.,
https://brickschema.org/schema/Brick#Hot_Water_Circulator_Pump,"Used to move hot water in a closed circuit, ensuring continuous flow.",
https://brickschema.org/schema/Brick#Hot_Water_Coil,"A heating element typically made of pipe, tube or wire that emits heat that is filled with hot water.",
https://brickschema.org/schema/Brick#Hot_Water_Differential_Pressure_Deadband_Setpoint,Sets the size of a deadband of differential pressure of hot water,
https://brickschema.org/schema/Brick#Hot_Water_Differential_Pressure_Integral_Time_Parameter,,
Expand Down
84 changes: 84 additions & 0 deletions bricksrc/equipment.py
Original file line number Diff line number Diff line change
Expand Up @@ -557,15 +557,99 @@
"subclasses": {
"Chilled_Water_Pump": {
"tags": [TAG.Equipment, TAG.Pump, TAG.Chilled, TAG.Water],
"subclasses": {
"Chilled_Water_Circulator_Pump": {
"tags": [
TAG.Equipment,
TAG.Pump,
TAG.Circulator,
TAG.Chilled,
TAG.Water,
],
"parents": [BRICK.Circulator_Pump],
},
"Chilled_Water_Booster_Pump": {
"tags": [
TAG.Equipment,
TAG.Pump,
TAG.Booster,
TAG.Chilled,
TAG.Water,
],
"parents": [BRICK.Booster_Pump],
},
},
},
"Condenser_Water_Pump": {
"tags": [TAG.Equipment, TAG.Pump, TAG.Condenser, TAG.Water],
"subclasses": {
"Condenser_Water_Circulator_Pump": {
"tags": [
TAG.Equipment,
TAG.Pump,
TAG.Circulator,
TAG.Condenser,
TAG.Water,
],
"parents": [BRICK.Circulator_Pump],
},
"Condenser_Water_Booster_Pump": {
"tags": [
TAG.Equipment,
TAG.Pump,
TAG.Booster,
TAG.Condenser,
TAG.Water,
],
"parents": [BRICK.Booster_Pump],
},
},
},
"Hot_Water_Pump": {
"tags": [TAG.Equipment, TAG.Pump, TAG.Hot, TAG.Water],
"subclasses": {
"Hot_Water_Circulator_Pump": {
"tags": [
TAG.Equipment,
TAG.Pump,
TAG.Circulator,
TAG.Hot,
TAG.Water,
],
"parents": [BRICK.Circulator_Pump],
"subclasses": {
"Domestic_Hot_Water_Circulator_Pump": {
"tags": [
TAG.Equipment,
TAG.Pump,
TAG.Circulator,
TAG.Hot,
TAG.Water,
TAG.Domestic,
],
},
},
},
"Hot_Water_Booster_Pump": {
"tags": [
TAG.Equipment,
TAG.Pump,
TAG.Booster,
TAG.Hot,
TAG.Water,
],
"parents": [BRICK.Booster_Pump],
},
},
},
},
},
"Circulator_Pump": {
"tags": [TAG.Equipment, TAG.Pump, TAG.Circulator],
},
"Booster_Pump": {
"tags": [TAG.Equipment, TAG.Pump, TAG.Booster],
},
},
},
"Heat_Exchanger": {
Expand Down

0 comments on commit fd3f5c3