Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

vebus: Enable PV inverter on AC output during wrong phase rotation and while not all AC inputs are powered #1327

Open
vejpasop opened this issue Jul 26, 2024 · 1 comment
Assignees

Comments

@vejpasop
Copy link
Collaborator

In systems with PV inverters running on the AC output of a Multi/Quattro the ESS/PV inverter assistant switches the PV inverters off by raising the AC output frequency during a short time while attempting to switch to grid. This in order to prevent the batteries from being overcharged.

When switching to grid fails, due to a phase rotation issue or due to missing AC input voltage, while at least on Multi/Quattro detects AC input, the PV inverters remain disabled.

Possibly we can fix this by letting mk2-dbus set the ignore AC input in this case.
The wrong phase rotation detection takes 30 seconds to become valid. During this time the PV inverters on the output will be disabled.

We need to consider any condition that would not allow connection to the grid. Such as high frequency, phase variations. etc

@vejpasop vejpasop self-assigned this Jul 26, 2024
@mpvader
Copy link
Contributor

mpvader commented Jul 27, 2024

Hey Jos, isn’t it better to first explore the options of fixing this in vebus fw?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants