Notifications
You must be signed in to change notification settings - Fork 3
/
Copy pathGet-UplinkDetails.psm1
128 lines (102 loc) · 4.06 KB
/
Get-UplinkDetails.psm1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
function Get-UplinkDetails {
<#
.NOTES
===========================================================================
Created by: Markus Kraus
Twitter: @VMarkus_K
Private Blog: mycloudrevolution.com
===========================================================================
Changelog:
2017.03 ver 1.0 Base Release
===========================================================================
External Code Sources:
Get-CDP Version from @LucD22
https://communities.vmware.com/thread/319553
===========================================================================
Tested Against Environment:
vSphere Version: vSphere 6.0 U2
PowerCLI Version: PowerCLI 6.3 R1
PowerShell Version: 4.0
OS Version: Server 2012 R2
Keyword: ESXi, Network, CDP, DVS, vSwitch, VMNIC
===========================================================================
.DESCRIPTION
This Function collects detailed informations about your ESXi Host connections to pSwitch and DVS / vSwitch
.Example
Get-UplinkDetails -Clustername * | ft -AutoSize
.Example
Get-UplinkDetails -Clustername MyCluster001 | ft -AutoSize
.Example
Get-UplinkDetails -Clustername MyCluster* | Sort Clustername, Hostname, DVS | ft -AutoSize
.PARAMETER Clustername
Your vSphere Cluster Name or Wildcard
#Requires PS -Version 4.0
#Requires -Modules VMware.VimAutomation.Core, @{ModuleName="VMware.VimAutomation.Core";ModuleVersion="6.3.0.0"}
#>
[CmdletBinding()]
param(
[Parameter(Mandatory=$True, ValueFromPipeline=$False, Position=0)]
[String] $Clustername
)
Begin {
$Validate = $True
if (($myCluster = Get-Cluster -Name $Clustername).count -lt 1) {
$Validate = $False
throw "No Cluster '$myCluster' found"
}
if (($myHosts = $myCluster | Get-VMHost).count -lt 1) {
$Validate = $False
throw "No Hosts in Cluster '$myCluster' found"
}
function Get-CDP ($VMhost){
$VMhostProxySwitch = $VMhost.NetworkInfo.ExtensionData.ProxySwitch
$VMhostSwitch = $VMhost.NetworkInfo.VirtualSwitch
$objReport = @()
$VMhost| %{Get-View $_.ID} |
%{ Get-View $_.ConfigManager.NetworkSystem} |
%{ foreach($physnic in $_.NetworkInfo.Pnic){
$obj = "" | Select-Object Clustername,Hostname,VMNIC,PCI,MAC,DVS,vSwitch,CDP_Port,CDP_Device,CDP_Address
$pnicInfo = $_.QueryNetworkHint($physnic.Device)
foreach($hint in $pnicInfo){
$obj.Clustername = $VMhost.parent.name
$obj.Hostname = $VMhost.name
$obj.VMNIC = $physnic.Device
$obj.PCI = $physnic.PCI
$obj.MAC = $physnic.Mac
if ($backing = ($VMhostProxySwitch | where {$_.Spec.Backing.PnicSpec.PnicDevice -eq $physnic.Device}).DvsName) {
$obj.DVS = $backing
} else {
$obj.DVS = "-No Backing-"
}
if ($backing = ($VMhostSwitch | where {$_.Nic -eq $physnic.Device}).Name) {
$obj.vSwitch = $backing
} else {
$obj.vSwitch = "-No Backing-"
}
if( $hint.ConnectedSwitchPort ) {
$obj.CDP_Port = $hint.ConnectedSwitchPort.PortId
$obj.CDP_Device = $hint.ConnectedSwitchPort.DevId
$obj.CDP_Address = $hint.ConnectedSwitchPort.Address
} else {
$obj.CDP_Port = "-No Info-"
$obj.CDP_Device = "-No Info-"
$obj.CDP_Address = "-No Info-"
}
}
$objReport += $obj
}
}
$objReport
}
}
Process {
$MyView = @()
if ($Validate -eq $True) {
foreach ($myHost in $myHosts) {
$CDP = Get-CDP $myHost
$MyView += $CDP
}
$MyView | Sort Clustername, Hostname, VMNIC
}
}
}