ioBroker.senec

senec adapter for ioBroker

Targeted at the Senec Home V2.1 System. Other systems might work, as long as they use lala.cgi.

Installation

You is facilitated via the ioBroker web interface and the configuration will auto-open once installation is completed.

Setup

In addition to the adapter installation you have to add an instance of the adapter.

Configuration

Main Settings

Feld Beschreibung
SENEC System Type in the IP-address of your SENEC system (FQDN is also possible if you have a working local DNS).
Polling Interval High Priority Data You can change the polling interval for high priority data (how often the Adapter reads from your Senec System), too. (Default: 10 seconds)
Polling Interval Low Priority Data You can change the polling interval for low priority data (how often the Adapter reads from your Senec System), too. (Default: 60 minutes)
Please be careful with high-frequency polling because this can render your SENEC machine unable to connect to the SENEC server!
Request-Timeout If your network requires a higher timeout for requests sent to SENEC, please change the Request-Timeout in miliseconds accordingly. (Default: 5000 miliseconds)
Polling Retries In case there is an issue communicating with SENEC the adapter will retry several times. You can adjust how often it will try to read from SENEC. (Default: 10)
This does not apply to Adapter Start - if the System is unavailable to Adapter will stop.
Polling Retry Factor To space retries apart a bit more you can adjust the Polling Retry Factor. (Default: 2) - Example: Using default settings the 1st retry will happen 20 seconds after the initial try, the 2nd will happen 40 seconds after the 2nd try. After each successful connect to SENEC, the number of retries is reset.

Once finished setting up configuration, hit SAVE AND CLOSE to leave configuration dialogue. The adapter will automatically restart.

Usage

Here you can find a description of the states and how to use them. All states of this adapter are read-only states. Depending on the individual system states might not be available or additional states could be there. If a state is not documented (or only partially documented) and you know what it represents, please send a pull request (or open a ticket with the information).

States

Channel: info

  • info.connection

    Data type Permission
    boolean R

    Read-only boolean which is true if the adapter is connected to the senec system.

Channel: BMS

  • BL[0-3]

    Data type Permission
    number R

    Read-only number, which represents ? for each battery pack.

  • CHARGED_ENERGY[0-3]

    Data type Permission
    number R

    Read-only number, which represents the amount of charged energy per battery pack in unit ?

  • CHARGE_CURRENT_LIMIT[0-3]

    Data type Permission
    number R

    Read-only number, which represents the current charge limit in Ampere per battery pack.

  • CURRENT[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's current in Ampere.

  • CYCLES[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's current charching cycles.

  • DISCHARGED_ENERGY[0-3]

    Data type Permission
    number R

    Read-only number, which represents the amount of energy discharged per battery in unit ?.

  • DISCHARGE_CURRENT_LIMIT[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's current discharge limit in Ampere.

  • FW[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's firmware version.

  • HW_EXTENSION[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's ?.

  • HW_MAINBOARD[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's mainboard version.

  • MAX_CELL_VOTAGE[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's maximum cell voltage in Volts.

  • MIN_CELL_VOTAGE[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's minimum cell voltage in Volts.

  • SN[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's serial number.

  • SOC[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's state of charge.

  • SOH[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's state of health.

  • STATUS[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's status.

  • TEMP_MAX[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's maximum temperature.

  • TEMP_MIN[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's minimum temperature.

  • VOLTAGE[0-3]

    Data type Permission
    number R

    Read-only number, which represents each battery pack's voltage in Volts.

  • BMS_READY_FLAG

    Data type Permission
    boolean R

    Read-only boolean, which represents if the BMS is ready.

  • MODULES_CONFIGURED

    Data type Permission
    number R

    Read-only number, which represents the number of modules currently configured in the system.

  • MODULE_COUNT

    Data type Permission
    number R

    Read-only number, which represents the number of modules currently known the system (incl. non-configured).

  • START_UPDATE

    Data type Permission
    boolean R

    Read-only boolean, which represents if an update is to be started.

  • WIZARD_ABORT

    Data type Permission
    boolean R

    Read-only boolean, which represents if the setup wizard was aborted.

  • WIZARD_CONFIRM

    Data type Permission
    boolean R

    Read-only boolean, which represents if the setup wizard was confirmed.

  • WIZARD_DCCONNECT

    Data type Permission
    boolean R

    Read-only boolean, which represents ?.

  • WIZARD_START

    Data type Permission
    number R

    Read-only boolean, which represents if the setup wizard is to be started.

  • WIZARD_STATE

    Data type Permission
    boolean R

    Read-only number, which represents the setup wizard's state.

Channel: ENERGY

  • GUI_BAT_DATA_CURRENT

    Data type Permission
    number R

    Read-only number, which represents the battery's current in Amps.

  • GUI_BAT_DATA_FUEL_CHARGE

    Data type Permission
    number R

    Read-only number, which represents the current level of your battery system in %.

  • GUI_BAT_DATA_VOLTAGE

    Data type Permission
    number R

    Read-only number, which represents the battery's current voltage in volt.

  • GUI_BAT_DATA_POWER

    Data type Permission
    number R

    Read-only number, which represents how much power is coming from / going into the battery in Watts. Negative values are discharging.

  • GUI_BOOSTING_INFO

    Data type Permission
    boolean R

    Read-only boolean, which we don't know the exact meaning of yet.

  • GUI_CHARGING_INFO

    Data type Permission
    boolean R

    Read-only boolean, which represents if the battery is currently charging.

  • GUI_GRID_POW

    Data type Permission
    number R

    Read-only number, which represents the power currenty coming from / going into the grid in Watts. Negative values are sending into the grid.

  • GUI_HOUSE_POW

    Data type Permission
    number R

    Read-only number, which represents the power in Watts currently consumed by the house.

  • GUI_INVERTER_POWER

    Data type Permission
    number R

    Read-only number, which represents the current power supplied by your PV system.

  • STAT_HOURS_OF_OPERATION

    Data type Permission
    number R

    Read-only number, detailing the system's uptime in hours.

  • STAT_MAINT_REQUIRED

    Data type Permission
    boolean R

    Read-only boolean, which represents if your senec system requires maintenance.

  • STAT_STATE

    Data type Permission
    number R

    Read-only number, which represents the system's state.

  • STAT_STATE_Text

    Data type Permission
    string R

    Read-only string, which represents the system's state in human readable format (sorry - we only have the german states from senec).

Channel: STATISTIC

  • STAT_DAY_BAT_CHARGE

    Data type Permission
    number R

    Read-only number, which represents the amount of power charged into the battery in kWh today.

  • STAT_DAY_BAT_DISCHARGE

    Data type Permission
    number R

    Read-only number, which represents the amount of power drawn from the battery in kWh today.

  • STAT_DAY_E_GRID_EXPORT

    Data type Permission
    number R

    Read-only number, which represents the amount of power in kWh delivered into the net today.

  • STAT_DAY_E_GRID_IMPORT

    Data type Permission
    number R

    Read-only number, which represents the amount of power in kWh drawn from the net today.

  • STAT_DAY_E_HOUSE

    Data type Permission
    number R

    Read-only number, which represents the amount of power in kWh consumed by the house today.

  • STAT_DAY_E_PV

    Data type Permission
    number R

    Read-only number, which represents the amount of power in kWh generated by your PV today.

Channel: SYS_UPDATE

  • NPU_IMAGE_VERSION

    Data type Permission
    number R

    Read-only number, representing the Revision NPU-IMAGE

  • NPU_VER

    Data type Permission
    number R

    Read-only number, representing the Revision NPU-REGS

  • UPDATE_AVAILABLE

    Data type Permission
    boolean R

    boolean-value which is true if there is an update available (Updates happen automatically and are scheduled by SENEC).

Channel: WIZARD

  • APPLICATION_VERSION

    Data type Permission
    string R

    Read-only text, representing the Revision MCU

  • CONFIG_LOADED

    Data type Permission
    boolean R

    boolean-value which is true if configuration is loaded. This being false is very unlikely and it shouldn't persist as false.

  • INTERFACE_VERSION

    Data type Permission
    string R

    Read-only text, representing the Revision GUI

  • SETUP_NUMBER_WALLBOXES

    Data type Permission
    number R

    Read-only number, which designates how many wallboxes are configured in the system.

  • SETUP_WALLBOX_SERIAL[0..3]

    Data type Permission
    string R

    Read-only text, which designates the serial number of wallbox [0..3].