diff --git a/Dell_iDRAC_fan_controller.sh b/Dell_iDRAC_fan_controller.sh index bdad2a4..e95a264 100644 --- a/Dell_iDRAC_fan_controller.sh +++ b/Dell_iDRAC_fan_controller.sh @@ -46,6 +46,18 @@ then exit 1 fi +# If server model is Gen 14 (*40) or newer +if [[ $SERVER_MODEL =~ .*[RT][[:space:]]?[0-9][4-9]0.* ]] +then + DELL_POWEREDGE_GEN_14_OR_NEWER=true + CPU1_TEMPERATURE_INDEX=2 + CPU2_TEMPERATURE_INDEX=4 +else + DELL_POWEREDGE_GEN_14_OR_NEWER=false + CPU1_TEMPERATURE_INDEX=1 + CPU2_TEMPERATURE_INDEX=2 +fi + # Log main informations echo "Server model: $SERVER_MANUFACTURER $SERVER_MODEL" echo "iDRAC/IPMI host: $IDRAC_HOST" @@ -138,15 +150,19 @@ while true; do fi fi - # Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response - # No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container - if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE + # If server model is Gen 14 (*40) or newer + if ! $DELL_POWEREDGE_GEN_14_OR_NEWER then - disable_third_party_PCIe_card_Dell_default_cooling_response - THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled" - else - enable_third_party_PCIe_card_Dell_default_cooling_response - THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled" + # Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response + # No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container + if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE + then + disable_third_party_PCIe_card_Dell_default_cooling_response + THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled" + else + enable_third_party_PCIe_card_Dell_default_cooling_response + THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled" + fi fi # Print temperatures, active fan control profile and comment if any change happened during last time interval diff --git a/functions.sh b/functions.sh index a0922ab..1ab29ed 100644 --- a/functions.sh +++ b/functions.sh @@ -38,10 +38,10 @@ function retrieve_temperatures () { # Parse CPU data local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}') - CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}') + CPU1_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU1_TEMPERATURE_INDEX;}") if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT then - CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}') + CPU2_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU2_TEMPERATURE_INDEX;}") else CPU2_TEMPERATURE="-" fi @@ -58,11 +58,13 @@ function retrieve_temperatures () { fi } +# /!\ Use this function only for Gen 13 and older generation servers /!\ function enable_third_party_PCIe_card_Dell_default_cooling_response () { # We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null } +# /!\ Use this function only for Gen 13 and older generation servers /!\ function disable_third_party_PCIe_card_Dell_default_cooling_response () { # We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null