forked from Morg42/viessmann
-
Notifications
You must be signed in to change notification settings - Fork 0
/
commands.py
executable file
·586 lines (570 loc) · 53.5 KB
/
commands.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
# !/usr/bin/env python
# ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ##
# Copyright 2020 Michael Wenzel
# ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ##
# Viessmann-Plugin for SmartHomeNG. https://github.com/smarthomeNG//
#
# This plugin is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# This plugin is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this plugin. If not, see <http://www.gnu.org/licenses/>.
# ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ##
controlset = {
'P300': {
'Baudrate': 4800,
'Bytesize': 8, # 'EIGHTBITS'
'Parity': 'E', # 'PARITY_EVEN',
'Stopbits': 2, # 'STOPBITS_TWO',
'StartByte': 0x41,
'Request': 0x00,
'Response': 0x01,
'Error': 0x03,
'Read': 0x01,
'Write': 0x02,
'Function_Call': 0x7,
'Acknowledge': 0x06,
'Not_initiated': 0x05,
'Init_Error': 0x15,
'Reset_Command': 0x04,
'Reset_Command_Response': 0x05,
'Sync_Command': 0x160000,
'Sync_Command_Response': 0x06,
'Command_bytes_read': 5,
'Command_bytes_write': 5,
# init: send'Reset_Command' receive'Reset_Command_Response' send'Sync_Command'
# request: send('StartByte' 'Länge der Nutzdaten als Anzahl der Bytes zwischen diesem Byte und der Prüfsumme' 'Request' 'Read' 'addr' 'checksum')
# request_response: receive('Acknowledge' 'StartByte' 'Länge der Nutzdaten als Anzahl der Bytes zwischen diesem Byte und der Prüfsumme' 'Response' 'Read' 'addr' 'Anzahl der Bytes des Wertes' 'Wert' 'checksum')
},
'KW': {
'StartByte': 0x01,
'Read': 0xF7,
'Write': 0xF4,
'Acknowledge': 0x05,
},
}
commandset = {
'V200KO1B': {
# Kessel
'Aussentemperatur': {'addr': '0800', 'len': 2, 'unit': 'IU10', 'set': False}, # Aussentemperatur
'Aussentemperatur_TP': {'addr': '5525', 'len': 2, 'unit': 'IU10', 'set': False}, # Aussentemperatur_tiefpass
'Aussentemperatur_Dp': {'addr': '5527', 'len': 2, 'unit': 'IU10', 'set': False}, # Aussentemperatur in Grad C (Gedaempft)
'Kesseltemperatur': {'addr': '0802', 'len': 2, 'unit': 'IU10', 'set': False}, # Kesseltemperatur
'Kesseltemperatur_TP': {'addr': '0810', 'len': 2, 'unit': 'IU10', 'set': False}, # Kesseltemperatur_tiefpass
'Kesselsolltemperatur': {'addr': '555A', 'len': 2, 'unit': 'IU10', 'set': False}, # Kesselsolltemperatur
'Temp_Speicher_Ladesensor': {'addr': '0812', 'len': 2, 'unit': 'IU10', 'set': False}, # Temperatur Speicher Ladesensor Komfortsensor
'Auslauftemperatur': {'addr': '0814', 'len': 2, 'unit': 'IU10', 'set': False}, # Auslauftemperatur
'Abgastemperatur': {'addr': '0816', 'len': 2, 'unit': 'IU10', 'set': False}, # Abgastemperatur
'Gem_Vorlauftemperatur': {'addr': '081a', 'len': 2, 'unit': 'IU10', 'set': False}, # Gem. Vorlauftemperatur
'Relais_K12': {'addr': '0842', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Relais K12 Interne Anschlußerweiterung
'Eingang_0-10_V': {'addr': '0a86', 'len': 1, 'unit': 'IUINT', 'set': False}, # Eingang 0-10 V
'EA1_Kontakt_0': {'addr': '0a90', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # EA1: Kontakt 0
'EA1_Kontakt_1': {'addr': '0a91', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # EA1: Kontakt 1
'EA1_Kontakt_2': {'addr': '0a92', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # EA1: Kontakt 2
'EA1_Externer_Soll_0-10V': {'addr': '0a93', 'len': 1, 'unit': 'IUINT', 'set': False}, # EA1: Externer Sollwert 0-10V
'EA1_Relais_0': {'addr': '0a95', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # EA1: Relais 0
'AM1_Ausgang_1': {'addr': '0aa0', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # AM1 Ausgang 1
'AM1_Ausgang_2': {'addr': '0aa1', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # AM1 Ausgang 2
'TempKOffset': {'addr': '6760', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 1193045}, # Kesseloffset KT ueber WWsoll in Grad C
'Systemtime': {'addr': '088E', 'len': 8, 'unit': 'TI', 'set': True}, # Systemzeit
'Anlagenschema': {'addr': '7700', 'len': 2, 'unit': 'SC', 'set': False}, # Anlagenschema
'DevType': {'addr': '00F8', 'len': 8, 'unit': 'DT', 'set': False}, # Heizungstyp
'Inventory': {'addr': '08E0', 'len': 7, 'unit': 'SN', 'set': False}, # Sachnummer
'CtrlId': {'addr': '08E0', 'len': 7, 'unit': 'DT', 'set': False}, # Reglerkennung
# Fehler
'Sammelstoerung': {'addr': '0a82', 'len': 1, 'unit': 'RT', 'set': False}, # Sammelstörung
'Error0': {'addr': '7507', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 1
'Error1': {'addr': '7510', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 2
'Error2': {'addr': '7519', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 3
'Error3': {'addr': '7522', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 4
'Error4': {'addr': '752B', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 5
'Error5': {'addr': '7534', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 6
'Error6': {'addr': '753D', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 7
'Error7': {'addr': '7546', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 8
'Error8': {'addr': '754F', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 9
'Error9': {'addr': '7558', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 10
# Pumpen
'Speicherladepumpe': {'addr': '6513', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Speicherladepumpe
'Zirkulationspumpe': {'addr': '6515', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Zirkulationspumpe
'Interne_Pumpe': {'addr': '7660', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Interne Pumpe
'Heizkreispumpe_A1M1': {'addr': '2906', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Heizkreispumpe A1
'Heizkreispumpe_A1M1_RPM': {'addr': '7663', 'len': 1, 'unit': 'IUNON', 'set': False}, # Heizkreispumpe A1M1 Drehzahl
'Heizkreispumpe_M2': {'addr': '3906', 'len': 1, 'unit': 'IUINT', 'set': False}, # Heizkreispumpe M2
'Heizkreispumpe_M2_RPM': {'addr': '7665', 'len': 1, 'unit': 'IUNON', 'set': False}, # Heizkreispumpe M2 Drehzahl
'Relais_Status_Pumpe_A1M1': {'addr': 'a152', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Relais-Status Heizkreispumpe 1
# Brenner
'Brennerstarts': {'addr': '088a', 'len': 4, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 1193045}, # Brennerstarts
'Brenner_Betriebsstunden': {'addr': '08a7', 'len': 4, 'unit': 'IU3600', 'set': True, 'min_value': 0, 'max_value': 1193045}, # Brenner-Betriebsstunden
'Brennerstatus_1': {'addr': '0842', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Brennerstatus Stufe1
'Brennerstatus_2': {'addr': '0849', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Brennerstatus Stufe2
'Oeldurchsatz': {'addr': '5726', 'len': 4, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 1193045}, # Oeldurchsatz Brenner in Dezi-Liter pro Stunde
'Oelverbrauch': {'addr': '7574', 'len': 4, 'unit': 'IS1000', 'set': True}, # Oelverbrauch kumuliert
#Solar
'Nachladeunterdrueckung': {'addr': '6551', 'len': 1, 'unit': 'IUBOOL', 'set': False},
'SolarPumpe': {'addr': '6552', 'len': 1, 'unit': 'IUBOOL', 'set': False},
'Kollektortemperatur': {'addr': '6564', 'len': 2, 'unit': 'IS10', 'set': False},
'Speichertemperatur': {'addr': '6566', 'len': 2, 'unit': 'IU10', 'set': False},
'Solar_Betriebsstunden': {'addr': '6568', 'len': 4, 'unit': 'IU100', 'set': False},
'Solarsteuerung': {'addr': '7754', 'len': 2, 'unit': 'IUINT', 'set': False},
# Heizkreis A1M1
'Raumtemperatur_A1M1': {'addr': '0896', 'len': 1, 'unit': 'ISNON', 'set': False}, # Raumtemperatur A1M1
'Raumtemperatur_Soll_Normalbetrieb_A1M1': {'addr': '2306', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 3, 'max_value': 37}, # Raumtemperatur Soll Normalbetrieb A1M1
'Raumtemperatur_Soll_Red_Betrieb_A1M1': {'addr': '2307', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 3, 'max_value': 37}, # Raumtemperatur Soll Reduzierter Betrieb A1M1
'Raumtemperatur_Soll_Party_Betrieb_A1M1': {'addr': '2308', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 3, 'max_value': 37}, # Raumtemperatur Soll Party Betrieb A1M1
'Aktuelle_Betriebsart_A1M1': {'addr': '2301', 'len': 1, 'unit': 'BA', 'set': False}, # Aktuelle Betriebsart A1M1
'Betriebsart_A1M1': {'addr': '2323', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 4}, # Betriebsart A1M1
'Sparbetrieb_A1M1': {'addr': '2302', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Sparbetrieb A1M1
'Zustand_Sparbetrieb_A1M1': {'addr': '2331', 'len': 1, 'unit': 'IUINT', 'set': False}, # Zustand Sparbetrieb A1M1
'Partybetrieb_A1M1': {'addr': '2303', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Partybetrieb A1M1
'Zustand_Partybetrieb_A1M1': {'addr': '2330', 'len': 1, 'unit': 'IUINT', 'set': False}, # Zustand Partybetrieb A1M1
'Vorlauftemperatur_A1M1': {'addr': '2900', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur A1M1
'Vorlauftemperatur_Soll_A1M1': {'addr': '2544', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur Soll A1M1
'StatusFrost_A1M1': {'addr': '2500', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Status Frostwarnung A1M1
'Externe_Raumsolltemperatur_Normal_A1M1': {'addr': '2321', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 37}, # Externe Raumsolltemperatur Normal A1M1
'Externe_Betriebsartenumschaltung_A1M1': {'addr': '2549', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 4}, # Externe Betriebsartenumschaltung A1M1
'Speichervorrang_A1M1': {'addr': '27A2', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 15}, # Speichervorrang auf Heizkreispumpe und Mischer
'Frostschutzgrenze_A1M1': {'addr': '27A3', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -9, 'max_value': 15}, # Frostschutzgrenze
'Frostschutz_A1M1': {'addr': '27A4', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Frostschutzgrenze
'Heizkreispumpenlogik_A1M1': {'addr': '27A5', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 15}, # HeizkreispumpenlogikFunktion
'Sparschaltung_A1M1': {'addr': '27A6', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 5, 'max_value': 35}, # AbsolutSommersparschaltung
'Mischersparfunktion_A1M1': {'addr': '27A7', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Mischersparfunktion
'Pumpenstillstandzeit_A1M1': {'addr': '27A9', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 15}, # Pumpenstillstandzeit
'Vorlauftemperatur_min_A1M1': {'addr': '27C5', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 1, 'max_value': 127}, # Minimalbegrenzung der Vorlauftemperatur
'Vorlauftemperatur_max_A1M1': {'addr': '27C6', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 10, 'max_value': 127}, # Maximalbegrenzung der Vorlauftemperatur
'Neigung_Heizkennlinie_A1M1': {'addr': '27D3', 'len': 1, 'unit': 'IU10', 'set': True, 'min_value': 0.2, 'max_value': 3.5}, # Neigung Heizkennlinie A1M1
'Niveau_Heizkennlinie_A1M1': {'addr': '27D4', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -13, 'max_value': 40}, # Niveau Heizkennlinie A1M1
'Partybetrieb_Zeitbegrenzung_A1M1': {'addr': '27F2', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 12}, # Zeitliche Begrenzung für Partybetrieb oder externe BetriebsprogrammUmschaltung mit Taster
'Temperaturgrenze_red_Betrieb_A1M1': {'addr': '27F8', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -61, 'max_value': 10}, # Temperaturgrenze für Aufhebung des reduzierten Betriebs -5 ºC
'Temperaturgrenze_red_Raumtemp_A1M1': {'addr': '27F9', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -60, 'max_value': 10}, # Temperaturgrenze für Anhebung des reduzierten RaumtemperaturSollwertes
'Vorlauftemperatur_Erhoehung_Soll_A1M1': {'addr': '27FA', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 50}, # Erhöhung des Kesselwasser- bzw. Vorlauftemperatur-Sollwertes beim Übergang von Betrieb mit reduzierter Raumtemperatur in den Betrieb mit normaler Raumtemperatur um 20 %
'Vorlauftemperatur_Erhoehung_Zeit_A1M1': {'addr': '27FA', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 150}, # Zeitdauer für die Erhöhung des Kesselwasser bzw.VorlauftemperaturSollwertes (siehe Codieradresse „FA“) 60 min.
# Heizkreis M2
'Raumtemperatur_M2': {'addr': '0898', 'len': 1, 'unit': 'ISNON', 'set': False}, # Raumtemperatur
'Raumtemperatur_Soll_Normalbetrieb_M2': {'addr': '3306', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 3, 'max_value': 37}, # Raumtemperatur Soll Normalbetrieb
'Raumtemperatur_Soll_Red_Betrieb_M2': {'addr': '3307', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 3, 'max_value': 37}, # Raumtemperatur Soll Reduzierter Betrieb
'Raumtemperatur_Soll_Party_Betrieb_M2': {'addr': '3308', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 3, 'max_value': 37}, # Raumtemperatur Soll Party Betrieb
'Aktuelle_Betriebsart_M2': {'addr': '3301', 'len': 1, 'unit': 'BA', 'set': False}, # Aktuelle Betriebsart
'Betriebsart_M2': {'addr': '3323', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 4}, # Betriebsart
'Sparbetrieb_M2': {'addr': '3302', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Sparbetrieb
'Zustand_Sparbetrieb_M2': {'addr': '3331', 'len': 1, 'unit': 'IUINT', 'set': False}, # Zustand Sparbetrieb
'Partybetrieb_M2': {'addr': '3303', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Partybetrieb
'Zustand_Partybetrieb_M2': {'addr': '3330', 'len': 1, 'unit': 'IUINT', 'set': False}, # Zustand Partybetrieb
'Vorlauftemperatur_M2': {'addr': '3900', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur
'Vorlauftemperatur_Soll_M2': {'addr': '3544', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur Soll
'StatusFrost_M2': {'addr': '3500', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Status Frostwarnung
'Externe_Raumsolltemperatur_Normal_M2': {'addr': '3321', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 37}, # Externe Raumsolltemperatur Normal
'Externe_Betriebsartenumschaltung_M2': {'addr': '3549', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 4}, # Externe Betriebsartenumschaltung
'Speichervorrang_M2': {'addr': '37A2', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 15}, # Speichervorrang auf Heizkreispumpe und Mischer
'Frostschutzgrenze_M2': {'addr': '37A3', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -9, 'max_value': 15}, # Frostschutzgrenze
'Frostschutz_M2': {'addr': '37A4', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Frostschutzgrenze
'Heizkreispumpenlogik_M2': {'addr': '37A5', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 15}, # HeizkreispumpenlogikFunktion
'Sparschaltung_M2': {'addr': '37A6', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 5, 'max_value': 35}, # AbsolutSommersparschaltung
'Mischersparfunktion_M2': {'addr': '37A7', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Mischersparfunktion
'Pumpenstillstandzeit_M2': {'addr': '37A9', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 15}, # Pumpenstillstandzeit
'Vorlauftemperatur_min_M2': {'addr': '37C5', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 1, 'max_value': 127}, # Minimalbegrenzung der Vorlauftemperatur
'Vorlauftemperatur_max_M2': {'addr': '37C6', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 10, 'max_value': 127}, # Maximalbegrenzung der Vorlauftemperatur
'Neigung_Heizkennlinie_M2': {'addr': '37D3', 'len': 1, 'unit': 'IU10', 'set': True, 'min_value': 0.2, 'max_value': 3.5}, # Neigung Heizkennlinie
'Niveau_Heizkennlinie_M2': {'addr': '37D4', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -13, 'max_value': 40}, # Niveau Heizkennlinie
'Partybetrieb_Zeitbegrenzung_M2': {'addr': '37F2', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 12}, # Zeitliche Begrenzung für Partybetrieb oder externe BetriebsprogrammUmschaltung mit Taster
'Temperaturgrenze_red_Betrieb_M2': {'addr': '37F8', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -61, 'max_value': 10}, # Temperaturgrenze für Aufhebung des reduzierten Betriebs -5 ºC
'Temperaturgrenze_red_Raumtemp_M2': {'addr': '37F9', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': -60, 'max_value': 10}, # Temperaturgrenze für Anhebung des reduzierten RaumtemperaturSollwertes
'Vorlauftemperatur_Erhoehung_Soll_M2': {'addr': '37FA', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 50}, # Erhöhung des Kesselwasser- bzw. Vorlauftemperatur-Sollwertes beim Übergang von Betrieb mit reduzierter Raumtemperatur in den Betrieb mit normaler Raumtemperatur um 20 %
'Vorlauftemperatur_Erhoehung_Zeit_M2': {'addr': '37Fb', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 150}, # Zeitdauer für die Erhöhung des Kesselwasser bzw.VorlauftemperaturSollwertes (siehe Codieradresse „FA“) 60 min.
# Warmwasser
'Warmwasser_Temperatur': {'addr': '0804', 'len': 2, 'unit': 'IU10', 'set': False}, # Warmwassertemperatur in Grad C
'Warmwasser_Solltemperatur': {'addr': '6300', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 10, 'max_value': 95}, # Warmwasser-Solltemperatur
'Status_Warmwasserbereitung':{'addr': '650a', 'len': 1, 'unit': 'IUBOOL', 'set': True, 'min_value': 0, 'max_value': 1}, # Satus Warmwasserbereitung
'WarmwasserPumpenNachlauf': {'addr': '6762', 'len': 2, 'unit': 'ISNON' , 'set': True, 'min_value': 0, 'max_value': 1}, # Warmwasserpumpennachlauf
# Ferienprogramm HK_A1M1
'Ferienprogramm_A1M1': {'addr': '2535', 'len': 1, 'unit': 'IUINT', 'set': False}, # Ferienprogramm A1M1
'Ferien_Abreisetag_A1M1': {'addr': '2309', 'len': 8, 'unit': 'DA', 'set': True}, # Ferien Abreisetag A1M1
'Ferien_Rückreisetag_A1M1': {'addr': '2311', 'len': 8, 'unit': 'DA', 'set': True}, # Ferien Rückreisetag A1M1
# Ferienprogramm HK_M2
'Ferienprogramm_M2': {'addr': '3535', 'len': 1, 'unit': 'IUINT', 'set': False}, # Ferienprogramm M2
'Ferien_Abreisetag_M2': {'addr': '3309', 'len': 8, 'unit': 'DA', 'set': True}, # Ferien Abreisetag M2
'Ferien_Rückreisetag_M2': {'addr': '3311', 'len': 8, 'unit': 'DA', 'set': True}, # Ferien Rückreisetag M2
# Schaltzeiten Warmwasser
'Timer_Warmwasser_Mo': {'addr': '2100', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Warmwasserbereitung Montag
'Timer_Warmwasser_Di': {'addr': '2108', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Warmwasserbereitung Dienstag
'Timer_Warmwasser_Mi': {'addr': '2110', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Warmwasserbereitung Mittwoch
'Timer_Warmwasser_Do': {'addr': '2118', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Warmwasserbereitung Donnerstag
'Timer_Warmwasser_Fr': {'addr': '2120', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Warmwasserbereitung Freitag
'Timer_Warmwasser_Sa': {'addr': '2128', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Warmwasserbereitung Samstag
'Timer_Warmwasser_So': {'addr': '2130', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Warmwasserbereitung Sonntag
# Schaltzeiten HK_A1M1
'Timer_A1M1_Mo': {'addr': '2000', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Montag
'Timer_A1M1_Di': {'addr': '2008', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Dienstag
'Timer_A1M1_Mi': {'addr': '2010', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Mittwoch
'Timer_A1M1_Do': {'addr': '2018', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Donnerstag
'Timer_A1M1_Fr': {'addr': '2020', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Freitag
'Timer_A1M1_Sa': {'addr': '2028', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Samstag
'Timer_A1M1_So': {'addr': '2030', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Sonntag
# Schaltzeiten HK_M2
'Timer_M2_Mo': {'addr': '3000', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Montag
'Timer_M2_Di': {'addr': '3008', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Dienstag
'Timer_M2_Mi': {'addr': '3010', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Mittwoch
'Timer_M2_Do': {'addr': '3018', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Donnerstag
'Timer_M2_Fr': {'addr': '3020', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Freitag
'Timer_M2_Sa': {'addr': '3028', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Samstag
'Timer_M2_So': {'addr': '3030', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Heizkreis_A1M1 Sonntag
# Schaltzeiten Zirkulation
'Timer_Zirku_Mo': {'addr': '2200', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Zirkulationspumpe Montag
'Timer_Zirku_Di': {'addr': '2208', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Zirkulationspumpe Dienstag
'Timer_Zirku_Mi': {'addr': '2210', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Zirkulationspumpe Mittwoch
'Timer_Zirku_Do': {'addr': '2218', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Zirkulationspumpe Donnerstag
'Timer_Zirku_Fr': {'addr': '2220', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Zirkulationspumpe Freitag
'Timer_Zirku_Sa': {'addr': '2228', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Zirkulationspumpe Samstag
'Timer_Zirku_So': {'addr': '2230', 'len': 8, 'unit': 'CT', 'set': True}, # Timer Zirkulationspumpe Sonntag
},
'V200HO1C': {
# Allgemein
'Frostgefahr': {'addr': '2510', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Frostgefahr
'Aussentemperatur_TP': {'addr': '5525', 'len': 2, 'unit': 'IU10', 'set': False}, # Aussentemperatur_tiefpass
'Aussentemperatur_Dp': {'addr': '5527', 'len': 2, 'unit': 'IU10', 'set': False}, # Aussentemperatur in Grad C (Gedaempft)
'Anlagenleistung': {'addr': 'a3af', 'len': 2, 'unit': 'IS10', 'set': False}, # Anlagenleistung
# Kessel
'Kesseltemperatur_TP': {'addr': '0810', 'len': 2, 'unit': 'IU10', 'set': False}, # Kesseltemperatur_tiefpass
'Kesselsolltemperatur': {'addr': '555A', 'len': 2, 'unit': 'IU10', 'set': False}, # Kesselsolltemperatur
'Abgastemperatur': {'addr': '0816', 'len': 2, 'unit': 'IU10', 'set': False}, # Abgastemperatur
# Fehler
'Sammelstoerung': {'addr': '0a82', 'len': 1, 'unit': 'RT', 'set': False}, # Sammelstörung
'Error0': {'addr': '7507', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 1
'Error1': {'addr': '7510', 'len': 9, 'unit': 'ES', 'set': False}, # Fehlerhistory Eintrag 2
# Pumpen
'Speicherladepumpe': {'addr': '6513', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Speicherladepumpe für Warmwasser
'Zirkulationspumpe': {'addr': '6515', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Zirkulationspumpe
'Interne_Pumpe': {'addr': '7660', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Interne Pumpe
'Heizkreispumpe_HK1': {'addr': '2906', 'len': 1, 'unit': 'IUBOOL', 'set': False}, # Heizkreispumpe A1
'Heizkreispumpe_HK2': {'addr': '3906', 'len': 1, 'unit': 'IUINT', 'set': False}, # Heizkreispumpe M2
# Brenner
'Brennerstarts': {'addr': '088a', 'len': 4, 'unit': 'ISNON', 'set': True, 'min_value': 0, 'max_value': 1193045}, # Brennerstarts
'Brennerleistung': {'addr': 'a305', 'len': 2, 'unit': 'IS10', 'set': False}, # Brennerleistung
'Brenner_Betriebsstunden': {'addr': '08a7', 'len': 4, 'unit': 'IU3600', 'set': True, 'min_value': 0, 'max_value': 1193045}, # Brenner-Betriebsstunden
#Solar
'SolarPumpe': {'addr': '6552', 'len': 1, 'unit': 'IUBOOL', 'set': False},
'Kollektortemperatur': {'addr': '6564', 'len': 2, 'unit': 'IS10', 'set': False},
'Speichertemperatur': {'addr': '6566', 'len': 2, 'unit': 'IU10', 'set': False},
'Solar_Betriebsstunden': {'addr': '6568', 'len': 4, 'unit': 'IU100', 'set': False},
'Solar_Waermemenge': {'addr': '6560', 'len': 2, 'unit': 'IUINT', 'set': False},
'Solar_Ausbeute': {'addr': 'CF30', 'len': 4, 'unit': 'IUINT', 'set': False},
# Heizkreis 1
'Betriebsart_HK1': {'addr': '2500', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 3}, # Betriebsart (0=Abschaltbetrieb, 1=Red. Betrieb, 2=Normalbetrieb (Schaltuhr), 3=Normalbetrieb (Dauernd))
'Heizart_HK1': {'addr': '2323', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 4}, # Heizart (0=Abschaltbetrieb, 1=Nur Warmwasser, 2=Heizen und Warmwasser, 3=Normalbetrieb (Dauernd))
'Vorlauftemperatur_Soll_HK1': {'addr': '2544', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur Soll
'Vorlauftemperatur_HK1': {'addr': '2900', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur Ist
# Heizkreis 2
'Betriebsart_HK2': {'addr': '3500', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 3}, # Betriebsart (0=Abschaltbetrieb, 1=Red. Betrieb, 2=Normalbetrieb (Schaltuhr), 3=Normalbetrieb (Dauernd))
'Heizart_HK2': {'addr': '3323', 'len': 1, 'unit': 'IUINT', 'set': True, 'min_value': 0, 'max_value': 4}, # Heizart (0=Abschaltbetrieb, 1=Nur Warmwasser, 2=Heizen und Warmwasser, 3=Normalbetrieb (Dauernd))
'Vorlauftemperatur_Soll_HK2': {'addr': '3544', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur Soll
'Vorlauftemperatur_HK2': {'addr': '3900', 'len': 2, 'unit': 'IU10', 'set': False}, # Vorlauftemperatur Ist
# Warmwasser
'Warmwasser_Temperatur': {'addr': '0812', 'len': 2, 'unit': 'IU10', 'set': False}, # Warmwassertemperatur in Grad C
'Warmwasser_Solltemperatur': {'addr': '6300', 'len': 1, 'unit': 'ISNON', 'set': True, 'min_value': 10, 'max_value': 95}, # Warmwasser-Solltemperatur
'Warmwasser_Austrittstemperatur': {'addr': '0814', 'len': 2, 'unit': 'IU10', 'set': False}, # Warmwasseraustrittstemperatur in Grad C
},
'V200WO1C': {
# generelle Infos
'Anlagentyp': {'addr': '00F8', 'len': 2, 'unit': 'DT', 'set': False}, # getAnlTyp -- Information - Allgemein: Anlagentyp (204D)
'Aussentemperatur': {'addr': '0101', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempA -- Information - Allgemein: Aussentemperatur (-40..70)
# Anlagenstatus
'Betriebsart': {'addr': 'B000', 'len': 1, 'unit': 'BA', 'set': True}, # getBetriebsart -- Bedienung HK1 - Heizkreis 1: Betriebsart (Textstring)
'Manuell': {'addr': 'B020', 'len': 1, 'unit': 'IUNON', 'set': True, 'min_value': 0, 'max_value': 2}, # getManuell / setManuell -- 0 = normal, 1 = manueller Heizbetrieb, 2 = 1x Warmwasser auf Temp2
'Sekundaerpumpe': {'addr': '0484', 'len': 1, 'unit': 'RT', 'set': False}, # getStatusSekP -- Diagnose - Anlagenuebersicht: Sekundaerpumpe 1 (0..1)
'Heizkreispumpe': {'addr': '048D', 'len': 1, 'unit': 'RT', 'set': False}, # getStatusPumpe -- Information - Heizkreis HK1: Heizkreispumpe (0..1)
'Zirkulationspumpe': {'addr': '0490', 'len': 1, 'unit': 'RT', 'set': False}, # getStatusPumpeZirk -- Information - Warmwasser: Zirkulationspumpe (0..1)
'VentilHeizenWW': {'addr': '0494', 'len': 1, 'unit': 'RT', 'set': False}, # getStatusVentilWW -- Diagnose - Waermepumpe: 3-W-Ventil Heizen WW1 (0 (Heizen)..1 (WW))
'Vorlaufsolltemp': {'addr': '1800', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempVLSoll -- Diagnose - Heizkreis HK1: Vorlaufsolltemperatur HK1 (0..95)
'Outdoor_Fanspeed': {'addr': '1A52', 'len': 1, 'unit': 'IUNON', 'set': False}, # getSpdFanOut -- Outdoor Fanspeed
'Status_Fanspeed': {'addr': '1A53', 'len': 1, 'unit': 'IUNON', 'set': False}, # getSpdFan -- Geschwindigkeit Luefter
'Kompressor_Freq': {'addr': '1A54', 'len': 1, 'unit': 'IUNON', 'set': False}, # getSpdKomp -- Compressor Frequency
# Temperaturen
'SolltempWarmwasser': {'addr': '6000', 'len': 2, 'unit': 'IS10', 'set': True, 'min_value': 10, 'max_value': 60}, # getTempWWSoll -- Bedienung WW - Betriebsdaten WW: Warmwassersolltemperatur (10..60 (95))
'VorlauftempSek': {'addr': '0105', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempSekVL -- Information - Heizkreis HK1: Vorlauftemperatur Sekundaer 1 (0..95)
'RuecklauftempSek': {'addr': '0106', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempSekRL -- Diagnose - Anlagenuebersicht: Ruecklauftemperatur Sekundaer 1 (0..95)
'Warmwassertemperatur': {'addr': '010d', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempWWIstOben -- Information - Warmwasser: Warmwassertemperatur oben (0..95)
# Stellwerte
'Raumsolltemp': {'addr': '2000', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempRaumSollNormal -- Bedienung HK1 - Heizkreis 1: Raumsolltemperatur normal (10..30)
'RaumsolltempReduziert': {'addr': '2001', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempRaumSollRed -- Bedienung HK1 - Heizkreis 1: Raumsolltemperatur reduzierter Betrieb (10..30)
'HeizkennlinieNiveau': {'addr': '2006', 'len': 2, 'unit': 'IS10', 'set': False}, # getHKLNiveau -- Bedienung HK1 - Heizkreis 1: Niveau der Heizkennlinie (-15..40)
'HeizkennlinieNeigung': {'addr': '2007', 'len': 2, 'unit': 'IS10', 'set': False}, # getHKLNeigung -- Bedienung HK1 - Heizkreis 1: Neigung der Heizkennlinie (0..35)
'RaumsolltempParty': {'addr': '2022', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempRaumSollParty -- Bedienung HK1 - Heizkreis 1: Party Solltemperatur (10..30)
# Statistiken / Laufzeiten
'EinschaltungenSekundaer': {'addr': '0504', 'len': 4, 'unit': 'IUNON', 'set': False}, # getAnzQuelleSek -- Statistik - Schaltzyklen Anlage: Einschaltungen Sekundaerquelle (?)
'EinschaltungenHeizstab1': {'addr': '0508', 'len': 4, 'unit': 'IUNON', 'set': False}, # getAnzHeizstabSt1 -- Statistik - Schaltzyklen Anlage: Einschaltungen Heizstab Stufe 1 (?)
'EinschaltungenHeizstab2': {'addr': '0509', 'len': 4, 'unit': 'IUNON', 'set': False}, # getAnzHeizstabSt2 -- Statistik - Schaltzyklen Anlage: Einschaltungen Heizstab Stufe 2 (?)
'EinschaltungenHK': {'addr': '050D', 'len': 4, 'unit': 'IUNON', 'set': False}, # getAnzHK -- Statistik - Schaltzyklen Anlage: Einschaltungen Heizkreis (?)
'LZSekundaerpumpe': {'addr': '0584', 'len': 4, 'unit': 'IU3600', 'set': False}, # getLZPumpeSek -- Statistik - Betriebsstunden Anlage: Betriebsstunden Sekundaerpumpe (?)
'LZHeizstab1': {'addr': '0588', 'len': 4, 'unit': 'IU3600', 'set': False}, # getLZHeizstabSt1 -- Statistik - Betriebsstunden Anlage: Betriebsstunden Heizstab Stufe 1 (?)
'LZHeizstab2': {'addr': '0589', 'len': 4, 'unit': 'IU3600', 'set': False}, # getLZHeizstabSt2 -- Statistik - Betriebsstunden Anlage: Betriebsstunden Heizstab Stufe 2 (?)
'LZPumpeHK': {'addr': '058D', 'len': 4, 'unit': 'IUNON', 'set': False}, # getLZPumpe -- Statistik - Betriebsstunden Anlage: Betriebsstunden Pumpe HK1 (0..1150000)
'LZWWVentil': {'addr': '0594', 'len': 4, 'unit': 'IU3600', 'set': False}, # getLZVentilWW -- Statistik - Betriebsstunden Anlage: Betriebsstunden Warmwasserventil (?)
'LZVerdichterStufe1': {'addr': '1620', 'len': 4, 'unit': 'IUNON', 'set': False}, # getLZVerdSt1 -- Statistik - Betriebsstunden Anlage: Betriebsstunden Verdichter auf Stufe 1 (?)
'LZVerdichterStufe2': {'addr': '1622', 'len': 4, 'unit': 'IUNON', 'set': False}, # getLZVerdSt2 -- Statistik - Betriebsstunden Anlage: Betriebsstunden Verdichter auf Stufe 2 (?)
'LZVerdichterStufe3': {'addr': '1624', 'len': 4, 'unit': 'IUNON', 'set': False}, # getLZVerdSt3 -- Statistik - Betriebsstunden Anlage: Betriebsstunden Verdichter auf Stufe 3 (?)
'LZVerdichterStufe4': {'addr': '1626', 'len': 4, 'unit': 'IUNON', 'set': False}, # getLZVerdSt4 -- Statistik - Betriebsstunden Anlage: Betriebsstunden Verdichter auf Stufe 4 (?)
'LZVerdichterStufe5': {'addr': '1628', 'len': 4, 'unit': 'IUNON', 'set': False}, # getLZVerdSt5 -- Statistik - Betriebsstunden Anlage: Betriebsstunden Verdichter auf Stufe 5 (?)
'VorlauftempSekMittel': {'addr': '16B2', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempSekVLMittel -- Statistik - Energiebilanz: mittlere sek. Vorlauftemperatur (0..95)
'RuecklauftempSekMittel': {'addr': '16B3', 'len': 2, 'unit': 'IS10', 'set': False}, # getTempSekRLMittel -- Statistik - Energiebilanz: mittlere sek.Temperatur RL1 (0..95)
'OAT_Temperature': {'addr': '1A5C', 'len': 1, 'unit': 'IUNON', 'set': False}, # getTempOAT -- OAT Temperature
'ICT_Temperature': {'addr': '1A5D', 'len': 1, 'unit': 'IUNON', 'set': False}, # getTempICT -- OCT Temperature
'CCT_Temperature': {'addr': '1A5E', 'len': 1, 'unit': 'IUNON', 'set': False}, # getTempCCT -- CCT Temperature
'HST_Temperature': {'addr': '1A5F', 'len': 1, 'unit': 'IUNON', 'set': False}, # getTempHST -- HST Temperature
'OMT_Temperature': {'addr': '1A60', 'len': 1, 'unit': 'IUNON', 'set': False}, # getTempOMT -- OMT Temperature
'LZVerdichterWP': {'addr': '5005', 'len': 4, 'unit': 'IU3600', 'set': False}, # getLZWP -- Statistik - Betriebsstunden Anlage: Betriebsstunden Waermepumpe (0..1150000)
'SollLeistungVerdichter': {'addr': '5030', 'len': 1, 'unit': 'IUNON', 'set': False}, # getPwrSollVerdichter -- Diagnose - Anlagenuebersicht: Soll-Leistung Verdichter 1 (0..100)
'WaermeWW12M': {'addr': '1660', 'len': 4, 'unit': 'IU10', 'set': False}, # Wärmeenergie für WW-Bereitung der letzten 12 Monate (kWh)
'ElektroWW12M': {'addr': '1670', 'len': 4, 'unit': 'IU10', 'set': False}, # elektr. Energie für WW-Bereitung der letzten 12 Monate (kWh)
},
}
unitset = {
'P300': {
'BA': {'unit_de': 'Betriebsart', 'type': 'list', 'signed': False, 'read_value_transform': 'non'}, # vito unit: BA
'CT': {'unit_de': 'CycleTime', 'type': 'timer', 'signed': False, 'read_value_transform': 'non'}, # vito unit: CT
'DT': {'unit_de': 'DeviceType', 'type': 'list', 'signed': False, 'read_value_transform': 'non'}, # vito unit: DT
'ES': {'unit_de': 'ErrorState', 'type': 'list', 'signed': False, 'read_value_transform': 'non'}, # vito unit: ES
'IU2': {'unit_de': 'INT unsigned 2', 'type': 'integer', 'signed': False, 'read_value_transform': '2'}, # vito unit: UT1U, PR1
'IU10': {'unit_de': 'INT unsigned 10', 'type': 'integer', 'signed': False, 'read_value_transform': '10'}, # vito unit:
'IU100': {'unit_de': 'INT unsigned 100', 'type': 'integer', 'signed': False, 'read_value_transform': '100'}, # vito unit:
'IU3600': {'unit_de': 'INT unsigned 3600', 'type': 'integer', 'signed': False, 'read_value_transform': '3600'}, # vito unit: CS
'IUBOOL': {'unit_de': 'INT unsigned bool', 'type': 'integer', 'signed': False, 'read_value_transform': 'bool'}, # vito unit:
'IUINT': {'unit_de': 'INT unsigned int', 'type': 'integer', 'signed': False, 'read_value_transform': 'int'}, # vito unit:
'IUNON': {'unit_de': 'INT unsigned non', 'type': 'integer', 'signed': False, 'read_value_transform': 'non'}, # vito unit: UTI, CO
'IS2': {'unit_de': 'INT signed 2', 'type': 'integer', 'signed': True, 'read_value_transform': '2'}, # vito unit: UT1, PR
'IS10': {'unit_de': 'INT signed 10', 'type': 'integer', 'signed': True, 'read_value_transform': '10'}, # vito unit: UT, UN
'IS100': {'unit_de': 'INT signed 100', 'type': 'integer', 'signed': True, 'read_value_transform': '100'}, # vito unit:
'IS1000': {'unit_de': 'INT signed 1000', 'type': 'integer', 'signed': True, 'read_value_transform': '1000'}, # vito unit:
'ISNON': {'unit_de': 'INT signed non', 'type': 'integer', 'signed': True, 'read_value_transform': 'non'}, # vito unit:
'RT': {'unit_de': 'ReturnStatus', 'type': 'list', 'signed': False, 'read_value_transform': 'non'}, # vito unit: ST, RT
'SC': {'unit_de': 'SystemScheme', 'type': 'list', 'signed': False, 'read_value_transform': 'non'}, # vito unit:
'SN': {'unit_de': 'Sachnummer', 'type': 'serial', 'signed': False, 'read_value_transform': 'non'}, # vito unit:
'SR': {'unit_de': 'SetReturnStatus', 'type': 'list', 'signed': False, 'read_value_transform': 'non'}, # vito unit:
'TI': {'unit_de': 'SystemTime', 'type': 'datetime', 'signed': False, 'read_value_transform': 'non'}, # vito unit: TI
'DA': {'unit_de': 'Date', 'type': 'date', 'signed': False, 'read_value_transform': 'non'}, # vito unit:
}
}
errorset = {
'P300': {
'00': 'Regelbetrieb (kein Fehler)',
'0F': 'Wartung (fuer Reset Codieradresse 24 auf 0 stellen)',
'10': 'Kurzschluss Aussentemperatursensor',
'18': 'Unterbrechung Aussentemperatursensor',
'20': 'Kurzschluss Vorlauftemperatursensor',
'21': 'Kurzschluss Ruecklauftemperatursensor',
'28': 'Unterbrechung Aussentemperatursensor',
'29': 'Unterbrechung Ruecklauftemperatursensor',
'30': 'Kurzschluss Kesseltemperatursensor',
'38': 'Unterbrechung Kesseltemperatursensor',
'40': 'Kurzschluss Vorlauftemperatursensor M2',
'42': 'Unterbrechung Vorlauftemperatursensor M2',
'50': 'Kurzschluss Speichertemperatursensor',
'58': 'Unterbrechung Speichertemperatursensor',
'92': 'Solar: Kurzschluss Kollektortemperatursensor',
'93': 'Solar: Kurzschluss Sensor S3',
'94': 'Solar: Kurzschluss Speichertemperatursensor',
'9A': 'Solar: Unterbrechung Kollektortemperatursensor',
'9B': 'Solar: Unterbrechung Sensor S3',
'9C': 'Solar: Unterbrechung Speichertemperatursensor',
'9E': 'Solar: Zu geringer bzw. kein Volumenstrom oder Temperaturwächter ausgeloest',
'9F': 'Solar: Fehlermeldung Solarteil (siehe Solarregler)',
'A7': 'Bedienteil defekt',
'B0': 'Kurzschluss Abgastemperatursensor',
'B1': 'Kommunikationsfehler Bedieneinheit',
'B4': 'Interner Fehler (Elektronik)',
'B5': 'Interner Fehler (Elektronik)',
'B6': 'Ungueltige Hardwarekennung (Elektronik)',
'B7': 'Interner Fehler (Kesselkodierstecker)',
'B8': 'Unterbrechung Abgastemperatursensor',
'B9': 'Interner Fehler (Dateneingabe wiederholen)',
'BA': 'Kommunikationsfehler Erweiterungssatz fuer Mischerkreis M2',
'BC': 'Kommunikationsfehler Fernbedienung Vitorol, Heizkreis M1',
'BD': 'Kommunikationsfehler Fernbedienung Vitorol, Heizkreis M2',
'BE': 'Falsche Codierung Fernbedienung Vitorol',
'C1': 'Externe Sicherheitseinrichtung (Kessel kuehlt aus)',
'C2': 'Kommunikationsfehler Solarregelung',
'C5': 'Kommunikationsfehler drehzahlgeregelte Heizkreispumpe, Heizkreis M1',
'C6': 'Kommunikationsfehler drehzahlgeregelte Heizkreispumpe, Heizkreis M2',
'C7': 'Falsche Codierung der Heizkreispumpe',
'C9': 'Stoermeldeeingang am Schaltmodul-V aktiv',
'CD': 'Kommunikationsfehler Vitocom 100 (KM-BUS)',
'CE': 'Kommunikationsfehler Schaltmodul-V',
'CF': 'Kommunikationsfehler LON Modul',
'D1': 'Brennerstoerung',
'D4': 'Sicherheitstemperaturbegrenzer hat ausgeloest oder Stoermeldemodul nicht richtig gesteckt',
'DA': 'Kurzschluss Raumtemperatursensor, Heizkreis M1',
'DB': 'Kurzschluss Raumtemperatursensor, Heizkreis M2',
'DD': 'Unterbrechung Raumtemperatursensor, Heizkreis M1',
'DE': 'Unterbrechung Raumtemperatursensor, Heizkreis M2',
'E4': 'Fehler Versorgungsspannung',
'E5': 'Interner Fehler (Ionisationselektrode)',
'E6': 'Abgas- / Zuluftsystem verstopft',
'F0': 'Interner Fehler (Regelung tauschen)',
'F1': 'Abgastemperaturbegrenzer ausgeloest',
'F2': 'Temperaturbegrenzer ausgeloest',
'F3': 'Flammensigal beim Brennerstart bereits vorhanden',
'F4': 'Flammensigal nicht vorhanden',
'F7': 'Differenzdrucksensor defekt',
'F8': 'Brennstoffventil schliesst zu spaet',
'F9': 'Geblaesedrehzahl beim Brennerstart zu niedrig',
'FA': 'Geblaesestillstand nicht erreicht',
'FD': 'Fehler Gasfeuerungsautomat',
'FE': 'Starkes Stoerfeld (EMV) in der Naehe oder Elektronik defekt',
'FF': 'Starkes Stoerfeld (EMV) in der Naehe oder interner Fehler'
},
}
operatingmodes = {
'V200KW2': {
'0': 'Abschaltbetrieb',
'1': 'Warmwasserbetrieb',
'2': 'Heiz- und Warmwasserbetrieb',
'4': 'Dauerbetrieb, reduziert',
'5': 'Dauerbetrieb, normal',
},
'V200KO1B': {
'00': 'Warmwasser (Schaltzeiten)',
'01': 'reduziert Heizen (dauernd)',
'02': 'normal Heizen (dauernd)',
'04': 'Heizen und Warmwasser (FS)',
'03': 'Heizen und Warmwasser (Schaltzeiten)',
'05': 'Standby',
},
'aktuelle_Betriebsart': {
'00': 'Abschaltbetrieb',
'01': 'Reduzierter Betrieb',
'02': 'Normalbetrieb',
'03': 'Dauernd Normalbetrieb',
},
'V200WO1C': {
'00': 'Abschaltbetrieb',
'01': 'Warmwasser',
'02': 'Heizen und Warmwasser',
'03': 'undefiniert',
'04': 'dauernd reduziert',
'05': 'dauernd normal',
'06': 'normal Abschalt',
'07': 'nur kühlen',
},
'V200HO1C': {
'00': 'Abschaltbetrieb',
'01': 'Warmwasser',
'02': 'Heizen und Warmwasser',
'03': 'Normal reduziert',
'04': 'Normal dauernd'
}
}
systemschemes = {
'V200KO1B': {
'01': 'A1',
'02': 'A1 + WW',
'04': 'M2',
'03': 'M2 + WW',
'05': 'A1 + M2',
'06': 'A1 + M2 + WW'
},
'V200WO1C': {
'01': 'WW',
'02': 'HK + WW',
'04': 'HK + WW',
'05': 'HK + WW'
},
'V200HO1C': {
'01': 'WW',
'02': 'HK + WW',
'04': 'HK + WW',
'05': 'HK + WW'
}
}
devicetypes = {
'2098': 'V200KW2, Protokoll: KW2',
'2053': 'GWG_VBEM, Protokoll: GWG',
'20CB': 'VScotHO1, Protokoll: P300',
'2094': 'V200KW1, Protokoll: KW2',
'209F': 'V200KO1B, Protokoll: P300, KW2',
'204D': 'V200WO1C, Protokoll: P300',
'20B8': 'V333MW1, Protokoll: ',
'20A0': 'V100GC1, Protokoll: ',
'20C2': 'VDensHO1, Protokoll: ',
'20A4': 'V200GW1, Protokoll: ',
'20C8': 'VPlusHO1, Protokoll: ',
'2046': 'V200WO1,VBC700, Protokoll: ',
'2047': 'V200WO1,VBC700, Protokoll: ',
'2049': 'V200WO1,VBC700, Protokoll: ',
'2032': 'VBC550, Protokoll: ',
'2033': 'VBC550, Protokoll: '
}
returnstatus = {
'P300': {
'00': '0',
'01': '1',
'03': '2',
'AA': 'NOT OK',
# At least for device 20CB the heating circuit pump returns status 03 when it's on and the heating runs in in night mode
},
}
setreturnstatus = {
'P300': {
'00': 'OK',
'05': 'SYNC (NOT OK)',
},
}
# P300 Protokoll
#
# Beispiel
#
# Senden 41 5 0 1 55 25 2 82
# Read Request -- - - - ----- - --
# | | | | | | +------- Prüfsumme (Summe über alley Bytes ohne die 41; [hex]5+0+1+55+25+2 = [dez]5+0+1+(5x16)+5+(2x16)+5+2 = 130dez = 82hex
# | | | | | +---------- XX Anzahl der Bytes, die in der Antwort erwartet werden
# | | | | +-------------- XX XX 2 byte Adresse der Daten oder Prozedur
# | | | +------------------ XX 01 = ReadData, 02 = WriteData, 07 = Function Call
# | | +-------------------- XX 00 = Anfrage, 01 = Antwort, 03 = Fehler
# | +---------------------- Länge der Nutzdaten (Anzahl der Bytes zwischen dem Telegramm-Start-Byte (0x41) und der Prüfsumme)
# +------------------------ Telegramm-Start-Byte
#
# Empfangen : 6 ----------------------- OK (Antwort auf 0x16 0x00 0x00 und auf korrekt empfangene Telegramme)
# 5 ----------------------- Schnittstelle ist aktiv und wartet auf eine Initialisierung
# 15 ----------------------- Schnittstelle meldet einen Fehler zurück
#
# 41 7 1 1 55 25 2 EF 0 74
# -- - - - ----- - ---- --
# | | | | | | | +-- Prüfsumme (Summe über alley Bytes ohne die 41; [hex]7+1+1+55+25+2+EF+0 = [dez]7+1+1+(5x16)+5+(2x16)+5+2+(14*16)+(15*16)+0 = [dez]7+1+1+(80)+5+(32)+5+2+(224)+(15)+0 = 372dez = 1.74hex)
# | | | | | | +------ Wert
# | | | | | +---------- XX Anzahl der Bytes, die in der Antwort erwartet werden
# | | | | +-------------- XX XX 2 byte Adresse der Daten oder Prozedur
# | | | +------------------ XX 01 = ReadData, 02 = WriteData, 07 = Function Call
# | | +-------------------- XX 00 = Anfrage, 01 = Antwort, 03 = Fehler
# | +---------------------- Länge der Nutzdaten (Anzahl der Bytes zwischen dem Telegramm-Start-Byte (0x41) und der Prüfsumme)
# +------------------------ Telegramm-Start-Byte
# Kommunikationsbeispiele
# Information Kessel Außentemperatur read 2-Byte -60..60 0x5525
# DATA TX: 41 5 0 1 55 25 2 82
# DATA RX: 41 7 1 1 55 25 2 EF 0 74 --> 00EF = 239 --> 23.9°C (Faktor 0.1)
# --> Senden 41 5 0 1 55 25 2 82
# -- - - - ----- - --
# | | | | | | +-- Prüfsumme (Summe über alley Bytes ohne die 41; [hex]5+0+1+55+25+2 = [dez]5+0+1+(5x16)+5+(2x16)+5+2 = 130dez = 82hex
# | | | | | +----- XX Anzahl der Bytes, die in der Antwort erwartet werden
# | | | | +--------- XX XX 2 byte Adresse der Daten oder Prozedur
# | | | +------------- XX 01 = ReadData, 02 = WriteData, 07 = Function Call
# | | +--------------- XX 00 = Anfrage, 01 = Antwort, 03 = Fehler
# | +----------------- Länge der Nutzdaten (Anzahl der Bytes zwischen dem Telegramm-Start-Byte (0x41) und der Prüfsumme)
# +------------------- Telegramm-Start-Byte
#
# --> Empfangen 6 41 7 1 1 55 25 2 EF 0 74
# - -- - - - ----- - ---- --
# | | | | | | | | +-- Prüfsumme (Summe über alley Bytes ohne die 41; [hex]7+1+1+55+25+2+EF+0 = [dez]7+1+1+(5x16)+5+(2x16)+5+2+(14*16)+(15*16)+0 = [dez]7+1+1+(80)+5+(32)+5+2+(224)+(15)+0 = 372dez = 1.74hex)
# | | | | | | | +------ Wert
# | | | | | | +---------- XX Anzahl der Bytes, die in der Antwort erwartet werden
# | | | | | +-------------- XX XX 2 byte Adresse der Daten oder Prozedur
# | | | | +------------------ XX 01 = ReadData, 02 = WriteData, 07 = Function Call
# | | | +-------------------- XX 00 = Anfrage, 01 = Antwort, 03 = Fehler
# | | +---------------------- Länge der Nutzdaten (Anzahl der Bytes zwischen dem Telegramm-Start-Byte (0x41) und der Prüfsumme)
# | +------------------------ Telegramm-Start-Byte
# +--------------------------- OK (Antwort auf 0x16 0x00 0x00 und auf korrekt empfangene Telegramme)
#
# --> Antwort: 0x00EF = 239 = 23.9°