forked from dedSyn4ps3/enviroplus-python
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathall-in-one-no-pm.py
executable file
·190 lines (158 loc) · 5.29 KB
/
all-in-one-no-pm.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
#!/usr/bin/env python3
import time
import colorsys
import os
import sys
import ST7735
try:
# Transitional fix for breaking change in LTR559
from ltr559 import LTR559
ltr559 = LTR559()
except ImportError:
import ltr559
from bme280 import BME280
from enviroplus import gas
from subprocess import PIPE, Popen
from PIL import Image
from PIL import ImageDraw
from PIL import ImageFont
from fonts.ttf import RobotoMedium as UserFont
import logging
logging.basicConfig(
format='%(asctime)s.%(msecs)03d %(levelname)-8s %(message)s',
level=logging.INFO,
datefmt='%Y-%m-%d %H:%M:%S')
logging.info("""all-in-one.py - Displays readings from all of Enviro plus' sensors
Press Ctrl+C to exit!
""")
# BME280 temperature/pressure/humidity sensor
bme280 = BME280()
# Create ST7735 LCD display class
st7735 = ST7735.ST7735(
port=0,
cs=1,
dc=9,
backlight=12,
rotation=270,
spi_speed_hz=10000000
)
# Initialize display
st7735.begin()
WIDTH = st7735.width
HEIGHT = st7735.height
# Set up canvas and font
img = Image.new('RGB', (WIDTH, HEIGHT), color=(0, 0, 0))
draw = ImageDraw.Draw(img)
path = os.path.dirname(os.path.realpath(__file__))
font_size = 20
font = ImageFont.truetype(UserFont, font_size)
message = ""
# The position of the top bar
top_pos = 25
# Displays data and text on the 0.96" LCD
def display_text(variable, data, unit):
# Maintain length of list
values[variable] = values[variable][1:] + [data]
# Scale the values for the variable between 0 and 1
vmin = min(values[variable])
vmax = max(values[variable])
colours = [(v - vmin + 1) / (vmax - vmin + 1) for v in values[variable]]
# Format the variable name and value
message = "{}: {:.1f} {}".format(variable[:4], data, unit)
logging.info(message)
draw.rectangle((0, 0, WIDTH, HEIGHT), (255, 255, 255))
for i in range(len(colours)):
# Convert the values to colours from red to blue
colour = (1.0 - colours[i]) * 0.6
r, g, b = [int(x * 255.0) for x in colorsys.hsv_to_rgb(colour, 1.0, 1.0)]
# Draw a 1-pixel wide rectangle of colour
draw.rectangle((i, top_pos, i + 1, HEIGHT), (r, g, b))
# Draw a line graph in black
line_y = HEIGHT - (top_pos + (colours[i] * (HEIGHT - top_pos))) + top_pos
draw.rectangle((i, line_y, i + 1, line_y + 1), (0, 0, 0))
# Write the text at the top in black
draw.text((0, 0), message, font=font, fill=(0, 0, 0))
st7735.display(img)
# Get the temperature of the CPU for compensation
def get_cpu_temperature():
process = Popen(['vcgencmd', 'measure_temp'], stdout=PIPE, universal_newlines=True)
output, _error = process.communicate()
return float(output[output.index('=') + 1:output.rindex("'")])
# Tuning factor for compensation. Decrease this number to adjust the
# temperature down, and increase to adjust up
factor = 2.25
cpu_temps = [get_cpu_temperature()] * 5
delay = 0.5 # Debounce the proximity tap
mode = 0 # The starting mode
last_page = 0
light = 1
# Create a values dict to store the data
variables = ["temperature",
"pressure",
"humidity",
"light",
"oxidised",
"reduced",
"nh3"]
values = {}
for v in variables:
values[v] = [1] * WIDTH
# The main loop
try:
while True:
proximity = ltr559.get_proximity()
# If the proximity crosses the threshold, toggle the mode
if proximity > 1500 and time.time() - last_page > delay:
mode += 1
mode %= len(variables)
last_page = time.time()
# One mode for each variable
if mode == 0:
# variable = "temperature"
unit = "C"
cpu_temp = get_cpu_temperature()
# Smooth out with some averaging to decrease jitter
cpu_temps = cpu_temps[1:] + [cpu_temp]
avg_cpu_temp = sum(cpu_temps) / float(len(cpu_temps))
raw_temp = bme280.get_temperature()
data = raw_temp - ((avg_cpu_temp - raw_temp) / factor)
display_text(variables[mode], data, unit)
if mode == 1:
# variable = "pressure"
unit = "hPa"
data = bme280.get_pressure()
display_text(variables[mode], data, unit)
if mode == 2:
# variable = "humidity"
unit = "%"
data = bme280.get_humidity()
display_text(variables[mode], data, unit)
if mode == 3:
# variable = "light"
unit = "Lux"
if proximity < 10:
data = ltr559.get_lux()
else:
data = 1
display_text(variables[mode], data, unit)
if mode == 4:
# variable = "oxidised"
unit = "kO"
data = gas.read_all()
data = data.oxidising / 1000
display_text(variables[mode], data, unit)
if mode == 5:
# variable = "reduced"
unit = "kO"
data = gas.read_all()
data = data.reducing / 1000
display_text(variables[mode], data, unit)
if mode == 6:
# variable = "nh3"
unit = "kO"
data = gas.read_all()
data = data.nh3 / 1000
display_text(variables[mode], data, unit)
# Exit cleanly
except KeyboardInterrupt: