- chargers with nuvoton-M0517 CPU don't have a dedicated internal temperature probe, we use the CPUs temperature.
- see also NiMH, NiCd charging.
- see also artificial adc noise.
- minimum allowed charge current is equal: =max("min Iout: Ic/X", "min Iout: YmA")
where: Ic - is batteries charge current ("edit battery"->"Ic:") - minimum allowed discharge current is equal: =max("min Iout: Id/X", "min Iout: YmA")
where: Id - is batteries discharge current ("edit battery"->"Id:")
"dis agres:" should be set to: yes - affects: charge/discharge of LiXX, Pb, NiZn and discharge of NiMH, NiCd
- the chargers design doesn't allow to deliver less current than a certain value,
(current measuring op-amp is not "rail-to-rail")
You can measure this value in "option"->"calibrate"->"I charge"->"100mA":- press "inc","dec" until measured current is the lowest possible but bigger than 0mA.
- press "stop" to exit (don't save this setting!)
- LiXX := Lipo, Life, Lilo, L430, L435, see ProgramData.cpp
name | description | charger type |
---|---|---|
UART: |
enable UART, should be "disabled" or "normal" | all |
speed: |
UART speed | all |
output: |
UART output: temp: temperature connector separ: temperature connector and UART are separated pin7: M0517 pin 7 (charger needs modification) |