# Example: Overpressure System
# ***Subsurface technical parameters***
# *************************************
Overpressure Percentage, 155.0
Overpressure Depletion Rate, 10.0
Injection Reservoir Temperature, 101.1, degC
Injection Reservoir Depth, 1001.1, meters
Injection Reservoir Inflation Rate, 202.2, kPa/yr
Starting Electricity Sale Price,0.09
Ending Electricity Sale Price,0.15
Electricity Escalation Start Year,5
Electricity Escalation Rate Per Year,0.012
Reservoir Model,1, ---Multiple Fractures reservoir model
Reservoir Depth,3, ---[km]
Number of Segments,1, ---[-]
Gradient 1,47, ---[deg.C/km]
Maximum Temperature,400, ---[deg.C]
Number of Production Wells,2, ---[-]
Number of Injection Wells,2, ---[-]
Production Well Diameter,9, ---[inch]
Injection Well Diameter,9, ---[inch]
Ramey Production Wellbore Model,1, ---0 if disabled 1 if enabled
Production Wellbore Temperature Drop,.5, ---[deg.C]
Injection Wellbore Temperature Gain,0, ---[deg.C]
Production Flow Rate per Well,70, ---[kg/s]
Fracture Shape,3, ---[-] Should be 1 2 3 or 4. See manual for details
Fracture Height,900, ---[m]
Reservoir Volume Option,3, ---[-] Should be 1 2 3 or 4. See manual for details
Number of Fractures,20, ---[-]
Reservoir Volume,1000000000, ---[m^3]
Water Loss Fraction,.02, ---[-]
Productivity Index,5, ---[kg/s/bar]
Injectivity Index,5, ---[kg/s/bar]
Injection Temperature,50, ---[deg.C]
Maximum Drawdown,1, ---[-] no redrilling considered
Reservoir Heat Capacity,1000, ---[J/kg/K]
Reservoir Density,2700, ---[kg/m^3]
Reservoir Thermal Conductivity,2.7, ---[W/m/K]
# ***SURFACE TECHNICAL PARAMETERS***
# **********************************
End-Use Option,1, ---[-] Electricity
Power Plant Type,2, ---[-] Supercritical ORC
Circulation Pump Efficiency,.8, ---[-] between .1 and 1
Utilization Factor,.9, ---[-] between .1 and 1
Surface Temperature,20, ---[deg.C]
Ambient Temperature,20, ---[deg.C]
# ***FINANCIAL PARAMETERS***
# **************************
Plant Lifetime,30, ---[years]
Economic Model,1, ---[-] Fixed Charge Rate Model
Fixed Charge Rate,.05, ---[-] between 0 and 1
Inflation Rate During Construction,0, ---[-]
# ***CAPITAL AND O&M COST PARAMETERS***
# *************************************
Well Drilling and Completion Capital Cost Adjustment Factor,1, ---[-] Use built-in correlations
Well Drilling Cost Correlation,1, ---[-] Use built-in correlations
Reservoir Stimulation Capital Cost Adjustment Factor,1, ---[-] Use built-in correlations
Surface Plant Capital Cost Adjustment Factor,1, ---[-] Use built-in correlations
Field Gathering System Capital Cost Adjustment Factor,1, ---[-] Use built-in correlations
Exploration Capital Cost Adjustment Factor,1, ---[-] Use built-in correlations
Wellfield O&M Cost Adjustment Factor,1, ---[-] Use built-in correlations
Surface Plant O&M Cost Adjustment Factor,1, ---[-] Use built-in correlations
Water Cost Adjustment Factor,1, ---[-] Use built-in correlations
# ***Simulation Parameters***
# ***************************
Print Output to Console,1, ---[-] Should be 0 (don't print results) or 1 (print results)
Time steps per year,6, ---[1/year]