#!/usr/bin/env python
import json
import math
import sys
from pydicom import Dataset, datadict, dcmread, dcmwrite
from impac_privates import impac_private_dict
if __name__ == "__main__":
energy_range_mm_dict = {}
energy_string_range_dict = {}
ion_plan_ds: Dataset = None
# Values calculated on PSTAR NIST web site at integer energies in MeV
# Assuming Linear Interpolation between integer energies is close enough
# for non-clinical purposes, like testing workflow/interoperability.
with open("proton_range_millimeters_water.json", "r") as f:
energy_string_range_dict = json.load(f)
energy_range_mm_dict = {int(x): y for x, y in energy_string_range_dict.items()}
datadict.add_private_dict_entries("IMPAC", impac_private_dict)
with open(sys.argv[1], "rb") as g:
ion_plan_ds = dcmread(g)
try:
impac_block = ion_plan_ds.IonBeamSequence[0].private_block(0x300B, "IMPAC")
if 0x04 in impac_block:
print(f"File already contains IMPAC private for {impac_private_dict[0x300B1004][2]}")
if len(sys.argv) < 2: # unless they want to force it with a -f or something
sys.exit()
except KeyError:
pass # no impac block so we're good to go
new_plan_name = sys.argv[1].removesuffix(".dcm") + "_ims_pvt.dcm"
for beam in ion_plan_ds.IonBeamSequence:
if beam.ScanMode not in ["MODULATED", "MODULATED_SPEC"]:
print(f"Scan Mode is {beam.ScanMode} which isn't supported in this script/module")
sys.exit()
cp_sequence = beam.IonControlPointSequence
cp_energy_list = [x.NominalBeamEnergy for x in cp_sequence]
max_energy = max(cp_energy_list)
min_energy = min(cp_energy_list)
ceiling_max_energy = math.ceil(max_energy)
floor_max_energy = math.floor(max_energy)
ceiling_max_weight = max_energy - floor_max_energy
ceiling_min_energy = math.ceil(min_energy)
floor_min_energy = math.floor(min_energy)
ceiling_min_weight = min_energy - floor_min_energy
# this isn't taking in to account a Range Shifter or a Range Modulator
# but for simple interoperability and workflow testing, it will do.
distal_range_millimeters = (
energy_range_mm_dict[floor_max_energy] * (1.0 - ceiling_max_weight)
+ energy_range_mm_dict[ceiling_max_energy] * ceiling_max_weight
)
proximal_range_millimeters = (
energy_range_mm_dict[floor_min_energy] * (1.0 - ceiling_min_weight)
+ energy_range_mm_dict[ceiling_min_energy] * ceiling_min_weight
)
sobp_equivalent_mm = round(distal_range_millimeters - proximal_range_millimeters, ndigits=1)
beam_max_radius_squared = 0
for cp in cp_sequence:
x_values = cp.ScanSpotPositionMap[0::2]
y_values = cp.ScanSpotPositionMap[1::2]
tuple_list = []
r_squared_list = [x * x + y * y for x, y in zip(x_values, y_values)]
max_r_squared = max(r_squared_list)
if beam_max_radius_squared < max_r_squared:
beam_max_radius_squared = max_r_squared
beam_max_radius = math.sqrt(beam_max_radius_squared)
new_private_block = beam.private_block(0x300B, "IMPAC", create=True)
new_private_block.add_new(0x04, "FL", round(distal_range_millimeters, 1))
new_private_block.add_new(0x02, "FL", round(beam_max_radius, 1))
new_private_block.add_new(0x0E, "FL", round(sobp_equivalent_mm, 1))
dcmwrite(
new_plan_name, ion_plan_ds, write_like_original=True
) # assume the input was ExplicitLittleEndian for later tasks, see convert_to_explicit_little_endian.py
print(f"Wrote updated file to {new_plan_name}")