Please see Releases
- #77 fix: silenced notifications not staying silenced (@sbender9)
- #75 fix: don't send "normal" notifications unless needed (@sbender9)
- #74 fix: don't ignore all null values coming over mqtt (@sbender9)
- #73 fix: preserve existing notification methods (@sbender9)
- #72 fix: relay display name entry not showing in plugin configuration (@sbender9)
- #70 fix: errors when a device goes away (@sbender9)
- #71 feature: add the ability to specify Display Name meta for relays (@sbender9)
- #69 fix: some mqtt values not getting refreshed (@sbender9)
- #68 fix: mqtt connection dropping after a minute (@sbender9)
- #67 fix: limit default debug logging (@sbender9)
- #66 feature: add support to get data via mqtt (@sbender9)
- #65 README: add warning about modifying the dbus conf (@mpvader)
- #64 fix: units for venus temperatures are wrong (@sbender9)
- #57 refactor: change "Blacklist" to "Block List" in the UI (@sbender9)
- #42 add frequency and discharge capacity (@dpreuss)
- #56 feature: add Inverter Only option for MultiPlus switch (@sbender9)
- #55 fix: unable to save the plugin config when there are no know paths (@sbender9)
- #54 feature: add ability to map vebus paths (@sbender9)
- #53 fix: mappings not always working (@sbender9)
- #52 fix: /Ac/L*/Volage typo (@sbender9)
- #51 fix: remove adding generic data for unknown data (@sbender9)
- #50 fix: /Ac/L*/Voltage has the wrong path (@sbender9)
- #49 fix: grid paths incorrect (@sbender9)
- #48 feature: add support for com.victronenergy.grid (@sbender9)
- #46 feature: add ability to blacklist specific paths (@sbender9)
- #45 feature: add option to disable getting position from Venus OS (@sbender9)
- #44 feature: add support for temperature sensors (@sbender9)
- #43 fix: convert kWh to Joules for solar yield (@sbender9)
- #40 fix: initial tank values updated at 'tanks.unknown' (@sbender9)
- #39 fix: gps values from dbus not working (@sbender9)
- #37 feature: support changing the vebus mode (@sbender9)
- #36 fix: battery relay state overwriting Venus relay 0 state (@sbender9)
- #35 feature: replace source with $source (@tkurki)
- #34 fix: gray/waste water tank not named correctly (@sbender9)
- #33 feature: provide total solar current and power (@sbender9)
- #32 feature: show state of digital inputs (@sbender9)
- #31 fix: absorption misspelled (@MichelleWhy)
- #30 fix: stateMaps for solarcharger to correct charging mode (@MichelleWhy)
- #28 feature: add ability to map venus instance numbers to different sk numbers (@sbender9)
- #25 chore: add license (@tkurki)
- #24 docs: remove outdated INSTALL-ON-VENUS & link to new info (@mpvader)
- #23 docs: Insert config above (@webmasterkai)
- #22 feature: provide status to the server (@sbender9)
- #21 feature: allow the signalk path name for the relays to be configured (@sbender9)
- #19 fix: send out null deltas for unknown values (@sbender9)
- #20 feature: add ESS mode for solar chargers (@sbender9)
- #18 feature: allow the poll interval to be configured (@sbender9)
- #17 fix: tank type names were not correct per the spec (@sbender9)
- #16 feature: added /ConsumedAmphours as electrical.batteries.{instance}.capacity.consumedCharge (@sbender9)
- #15 fix: store /Dc/1/Voltage under batteries.{instance}-second.voltage (@sbender9)
- #14 fix: crash when an alarm is on (@sbender9)
- #13 change: updated to latest server PUT api's (@sbender9)
- #12 chore: change relays paths to closer match current spec RFC (@sbender9)
- #11 feature: add support to switch relays using PUT (@sbender9)
- #10 Add reconnecting to remote dbus (@tkurki)
- #8 add polling of dbus (@mpvader)