Hi @rokel, That's true, the underlying OPC UA Client doesn't have an event-driven main loop or its own thread, so we must call periodically We chose a default value of 1000ms, which may be too slow as a default value -- we can look into that. In any case, we should definitely provide an option to configure run_async_timeout via XML. The plumbing for such configuration parameter is almost there, let me take a look at it'll create a PR with the new configuration parameter. Would this work for you? |
Thank you for the prompt response and explanation, that makes sense. Yes, a configuration parameter to set this would certainly solve the issue for us. |
When using the OPC-UA -> DDS route, the publish rate of the gateway seems to be throttled to 1Hz, regardless of the
publishing_interval
set for any subscription.As far as I can tell this is due to this hard-coded parameter:
https://github.com/rticommunity/rticonnextdds-gateway-opcua/blob/master/src/opcUaSdk/OpcUaSdkClientProperty.hpp#L28
Changing e.g. to 10ms it seems to fix the issue. Is this intended behaviour?